  • Candefjord, Stefan, et al. (författare)
  • Effects of snap-freezing and near-infrared laser illumination on porcine prostate tissue as measured by Raman spectroscopy
  • 2009
  • Ingår i: The Analyst. - : Royal Society of Chemistry (RSC). - 0003-2654 .- 1364-5528. ; 134:9, s. 1815-1821
  • Tidskriftsartikel (refereegranskat)abstract
    • Most Raman spectroscopic studies on tissue are performed in vitro. To assure that the results are applicable to in vivo examinations, preparation protocols and measurement procedures of tissue for in vitro studies should preserve tissue characteristics close to the native state. This study had two aims. The first was to elucidate if photoinduced effects arise during 5 minutes' continuous illumination of tissue with an 830 nm laser at an irradiance of 3 × 1010 W/m2. The second was to investigate the effects of snap-freezing of porcine prostate tissue in liquid nitrogen and subsequent storage at -80 °C, by means of multivariate analysis. 830 nm laser illumination of the specified irradiance did not affect the Raman spectra. A decrease of the spectral background was observed, likely due to photobleaching of tissue fluorophores. Snap-freezing and subsequent storage at -80 °C gave rise to subtle but significant alterations in Raman spectra, most likely related to changes in the protein conformations
  •  
3.
  •  
4.
  • Candefjord, Stefan, et al. (författare)
  • Evaluating the use of a Raman fiberoptic probe in conjunction with a resonance sensor for measuring porcine tissue in vitro
  • 2009
  • Ingår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering. - Heidelberg : Springer. ; , s. 414-417, s. 414-417
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer and is the third leading cause of cancer-related death in European men. There is a need for new methods that can accurately localize and diagnose prostate cancer. In this study a new approach is presented: a combination of resonance sensor technology and Raman spectroscopy. Both methods have shown promising results for prostate cancer detection in vitro. The aim of this study was to evaluate the combined information from measurements with a Raman fiberoptic probe and a resonance sensor system. Pork belly tissue was used as a model system. A three-dimensional translation table was equipped with an in-house developed software, allowing measurements to be performed at the same point using two separate instruments. The Raman data was analyzed using principal component analysis and hierarchical clustering analysis. The spectra were divided into 5 distinct groups. The mean stiffness of each group was calculated from the resonance sensor measurements. One of the groups differed significantly (p < 0.05) from the others. A regression analysis, with the stiffness parameter as response variable and the principal component scores of the Raman data as the predictor variables, explained 67% of the total variability. The use of a smaller resonance sensor tip would probably increase the degree of correlation. In conclusion, Raman spectroscopy provides additional discriminatory power to the resonance sensor.
  •  
5.
  •  
6.
  • Candefjord, Stefan, et al. (författare)
  • Technologies for localization and diagnosis of prostate cancer
  • 2009
  • Ingår i: Journal of Medical Engineering & Technology. - : Informa UK Limited. - 0309-1902 .- 1464-522X. ; 33:8, s. 585-603
  • Tidskriftsartikel (refereegranskat)abstract
    • The gold standard for detecting prostate cancer (PCa), systematic biopsy, lacks sensitivity as well as grading accuracy. PSA screening leads to over-treatment of many men, and it is unclear whether screening reduces PCa mortality. This review provides an understanding of the difficulties of localizing and diagnosing PCa. It summarizes recent developments of ultrasound (including elastography) and MRI, and discusses some alternative experimental techniques, such as resonance sensor technology and vibrational spectroscopy. A comparison between the different methods is presented. It is concluded that new ultrasound techniques are promising for targeted biopsy procedures, in order to detect more clinically significant cancers while reducing the number of cores. MRI advances are very promising, but MRI remains expensive and MR-guided biopsy is complex. Resonance sensor technology and vibrational spectroscopy have shown promising results in vitro. There is a need for large prospective multicentre trials that unambiguously prove the clinical benefits of these new techniques.
  •  
7.
  •  
8.
  • Eklund, Anders, 1965-, et al. (författare)
  • A resonator sensor for measurement of intraocular pressure : evaluation in an in vitro pig-eye model
  • 2000
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 21:3, s. 355-367
  • Tidskriftsartikel (refereegranskat)abstract
    • Intraocular pressure (IOP) measurement is performed routinely at every eye clinic. High IOP, which can be a sign of glaucoma, can lead to degeneration of the retina and can cause blindness. In this study we developed a resonator sensor for IOP measurement based on an oscillator consisting of a piezoelectric element made of lead zirconate titanate, a flat contact piece of nylon and a feedback circuit. The aim of this study was to evaluate the new sensor's ability to determine lOP in an in vitro pig-eye model. Six eyes from four pigs were removed and fixed in agar. They were then pressurized by a saline column (10-35 cm H2O) through a cannula inserted into the vitreous chamber. The IOP was measured with the resonator sensor applied to cornea. An Alcon applanation pneumatonometer and a standard Viggo-Spectramed pressure sensor connected to the saline column were used as references. The IOP as measured with the resonator sensor correlated well with the pressure elicited by the saline column for individual eyes (r = 0.96-0.99, n = 60) and for all eyes (r = 0.92, n = 360). The correlation between the resonance sensor and the pneumatonometer was r = 0.92 (n = 360). The pneumatonometer also showed a good correlation with the saline column (r = 0.98, n = 360). We conclude that our in vitro pig-eye model made it possible to induce reproducible variation in IOP, and measurement of that pressure with the newly developed resonator sensor gave very promising results for development of a clinically applicable IOP tonometer with unique properties.
  •  
9.
  • Eklund, Anders, et al. (författare)
  • An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement
  • 2003
  • Ingår i: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology (ARVO). - 0146-0404 .- 1552-5783. ; 44:7, s. 3017-24
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring intraocular pressure (IOP). The purpose of this study was to develop a new applanation method for IOP measurement that uses combined continuous force and area measurement and to develop and evaluate an applanation resonator sensor (ARS) tonometer based on that method. METHODS: The tonometer was developed and evaluated in an in vitro porcine eye model, in which enucleated eyes were pressurized with a saline column. A model assuming that the applanation principle is valid over a certain interval of contact area was proposed. Continuous contact area was measured with a resonator sensor device, and contact force was measured with a force transducer, both mounted together in one probe. Reference IOP was measured in the vitreous chamber (IOP(VC)) with a standard fluid pressure transducer. RESULTS: An optimization algorithm determined the applanation interval that was optimal for calculating IOP(ARS). The corresponding time interval was 30 +/- 3 to 77 +/- 4 ms (mean +/- SD, n = 418) after initial contact. The proposed model showed a degree of explanation of R(2 [supi]) = 0.991 (n = 410, six eyes), corresponding to a correlation of r = 0.995 (n = 410) between IOP(ARS) and IOP(VC). The within-eyes precision (i.e., 95% confidence interval for the residuals between IOP(ARS) and IOP(VC)) was +/- 1.8 mm Hg (n = 410, six eyes). CONCLUSIONS: In this study, the ARS method for measuring IOP was evaluated in an in vitro porcine eye model and showed high precision. The ARS method is, to the authors' knowledge, the first to combine simultaneous, continuous sampling of both parameters included in the applanation principle: force and area. Consequently, there is a potential for reducing errors in clinical IOP tonometry.
  •  