1.
  •  
2.
  • Aznar, Marianne C., et al. (författare)
  • A Monte Carlo study of the energy dependence of Al2O3:C crystals for real-time in vivo dosimetry in mammography
  • 2005
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:Nos 1-3, s. 444-449
  • Tidskriftsartikel (refereegranskat)abstract
    • In a previous experimental study, a novel method for in vivo dosimetry has been investigated, based on radioluminescence (RL) and optically stimulated luminescence (OSL). However, because of the large difference in atomic composition between the detector material and the breast tissue, relatively large energy dependence in low-energy X-ray beams can be expected. In the present work, the energy dependence of Al2O3:C crystals was modelled with the Monte Carlo code EGSnrc using three types of X-ray spectra. The results obtained (5.6-7.3%) agree with a previously determined experimental result (9%) within the combined standard uncertainty of the two methods. The influence of the size of the crystal on the energy dependence was investigated together with the effect of varying the thickness of the surrounding light-protective material. The results obtained indicate a minor effect owing to the thickness of the light-protective material, and a somewhat larger effect from reducing the diameter of the crystal. The outcome of this study can be used to improve the future design of the RL/OSL dosimetry system for use in mammography.
  •  
3.
  • Aznar, MC, et al. (författare)
  • In vivo absorbed dose measurements in mammography using a new real-time luminescence technique
  • 2005
  • Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 1748-880X .- 0007-1285. ; 78:928, s. 328-334
  • Tidskriftsartikel (refereegranskat)abstract
    • A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography.
  •  
4.
  • Båth, Magnus, 1974, et al. (författare)
  • Nodule detection in digital chest radiography: introduction to the RADIUS chest trial.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 85-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Most digital radiographic systems of today have wide latitude and are hence able to provide images with a small constraint on dose level. This opens up for an unprejudiced dose optimisation. However, in order to succeed in the optimisation task, good knowledge of the imaging and detection processes is needed. As a part of the European-wide research project 'unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial was focused on the detection of lung nodules in digital chest radiography with the aims of determining to what extent (1) the detection of a nodule is dependent on its location, (2) the system noise disturbs the detection of lung nodules, (3) the anatomical noise disturbs the detection of lung nodules and (4) the image background and anatomical background act as pure noise for the detection of lung nodules. The purpose of the present paper is to give an introduction to the trial and describe the framework and set-up of the investigation.
  •  
5.
  • Börjesson, Sara, et al. (författare)
  • A software tool for increased efficiency in observer performance studies in radiology.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 45-52
  • Tidskriftsartikel (refereegranskat)abstract
    • Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-has been developed in Java, enabling it to function on almost any computer. ViewDEX is designed to handle several types of studies, such as visual grading analysis (VGA), image criteria scoring (ICS) and receiver operating characteristics (ROC). The results from each observer are saved in a log file, which can be exported for further analysis in, for example, a special software for analysing ROC results. By using ViewDEX for an ROC experiment, an evaluation rate of approximately 200 images per hour can be achieved, compared to approximately 25 images per hour using hard copy evaluation. The results are obtained within minutes of completion of the viewing. The risk of human errors in the process of data collection and analysis is also minimised. The viewer has been used in a major trial containing approximately 2700 images.
  •  
6.
  • Hemdal, Bengt, et al. (författare)
  • Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 383-8
  • Tidskriftsartikel (refereegranskat)abstract
    • There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.
  •  
7.
  • Hemdal, Bengt, et al. (författare)
  • Clinical evaluation of a new set of image quality criteria for mammography.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 389-94
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.
  •  
8.
  • Håkansson, Markus, et al. (författare)
  • Nodule detection in digital chest radiography: summary of the RADIUS chest trial.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 114-20
  • Tidskriftsartikel (refereegranskat)abstract
    • As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.
  •  
9.
  • Mattsson, Sören (författare)
  • Optimisation strategies in medical X-ray imaging
  • 2005
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 114:1-3, s. 1-1
  • Tidskriftsartikel (refereegranskat)
  •  
10.
  • Moores, B M, et al. (författare)
  • RADIUS--closing the circle on the assessment of imaging performance.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 450-7
  • Tidskriftsartikel (refereegranskat)abstract
    • The RADIUS (Radiological Imaging Unification Strategy) project addresses the assessment of image quality in terms of both physical and clinically relevant measures. The aim is to unify our understanding of both types of measure as well as the numerous underlying factors that play a key role in the assessments of imaging performance. In this way it is expected to provide a solid basis for the improvement in radiological safety management, where not only radiation risks are considered but also diagnostic risks of incorrect clinical outcomes (i.e. false positive/false negative). The project has applied a variety of relevant experimental and theoretical methods to this problem, which is generic to medical imaging as a whole. Digital radiography of the chest and the breast has been employed as the clinical imaging domain vehicles for the study. The project addressed the problem from the following directions: role and relevance of pathology, human observer studies including receiver operating characteristics, image quality criteria analysis, structural noise analysis, physical measurements on clinical images, physical measurements on imaging system, modelling of imaging system, modelling of visual processes, modelling of doses delivered and IT-based scientific support strategies. This paper presents an overview of the main outcomes from this project and highlights how the research outcomes actually apply to the real world. In particular, attention will be focused on new and original findings and methods and techniques that have been developed within the framework of the project. The relevance of the project's outcomes to future European research will also be presented.
  •  