SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:miun ;lar1:(kth);pers:(Thungström Göran)"

Sökning: LAR1:miun > Kungliga Tekniska Högskolan > Thungström Göran

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ashraf, Shakeel, 1984-, et al. (författare)
  • Thermoelectric Properties of n-Type Molybdenum Disulfide (MoS2) Thin Film by Using a Simple Measurement Method
  • 2019
  • Ingår i: Materials. - : MDPI. - 1996-1944 .- 1996-1944. ; 12:21
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, a micrometre thin film of molybdenum disulfide (MoS2) is characterized for thermoelectric properties. The sample was prepared through mechanical exfoliation of a molybdenite crystal. The Seebeck coefficient measurement was performed by generating a temperature gradient across the sample and recording the induced electrical voltage, and for this purpose a simple measurement setup was developed. In the measurement, platinum was utilized as reference material in the electrodes. The Seebeck value of MoS2 was estimated to be approximately -600 mu V/K at a temperature difference of 40 degrees C. The negative sign indicates that the polarity of the material is n-type. For measurement of the thermal conductivity, the sample was sandwiched between the heat source and the heat sink, and a steady-state power of 1.42 W was provided while monitoring the temperature difference across the sample. Based on Fourier's law of conduction, the thermal conductivity of the sample was estimated to be approximately 0.26 Wm(-1) K-. The electrical resistivity was estimated to be 29 Omega cm. The figure of merit of MoS2 was estimated to be 1.99 x 10(-4).
  •  
2.
  • Bertilsson, Kent, et al. (författare)
  • Simulation of a low atmospheric-noise modified four-quadrant position sensitive detector
  • 2001
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 466:1, s. 183-187
  • Tidskriftsartikel (refereegranskat)abstract
    • A modified four-quadrant position sensitive detector (PSD) is developed. This structure is less sensitive to atmospheric turbulence that is a major drawback with the traditional four-quadrant detector. The inter-electrode resistance is as high as for the four-quadrant detector, which is an advantage compared to the lateral effect PSD. The linearity for the modified four-quadrant detector is good in the whole active range of sensing. The structures are limited to small sensing areas with well focused beams and are suitable for use in detectors up to 1 mm in size.
  •  
3.
  • Kok, A., et al. (författare)
  • Silicon sensors with pyramidal structures for neutron imaging
  • 2014
  • Ingår i: Journal of Instrumentation. - 1748-0221 .- 1748-0221. ; 9, s. C04011-
  • Tidskriftsartikel (refereegranskat)abstract
    • Neutron detection is a valuable tool in nuclear science research, homeland security, quality assurance in nuclear plants and medical applications. Recent developments and near future instrumentations in neutron imaging have a need for sensors with high spatial resolution, dynamic range, sensitivity and background discrimination. Silicon based neutron detectors can potentially fulfil these requirements. In this work, pad and pixel detectors with pyramidal micro-structures have been successfully fabricated that should have an improved detection efficiency when compared to conventional planar devices. Titanium di-boride (TiB2) and lithium fluoride (LiF) were deposited as the neutron converters. Excellent electrical performances were measured on both simple pad and pixel detectors. A selection of pad detectors was examined by alpha spectroscopy. Measurement with thermal neutrons from a 241Am-Be source shows an improvement in relative efficiency of up to 38% when compared to conventional planar devices.
  •  
4.
  • Mattsson, Claes, et al. (författare)
  • Manufacturing and characterization of a modified four-quadrant position sensitive detector for out-door applications
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 531:1-2, s. 134-139
  • Tidskriftsartikel (refereegranskat)abstract
    • Position sensing detectors (PSDs) are useful in many applications such as vibration, displacement and triangulation measurements. In this paper we have constructed a novel structure, which has higher inter-electrode resistance than a lateral effect PSD and is more robust to atmospheric turbulence than a conventional four-quadrant PSD (Nuclear Instruments and Methods in Physics Research A 466 (2001) 183). The detector structure is useful for applications with detector windows less than 0.5 x 0.5 mm(2), but the nonlinearity is the main concern for a detector of that size. Without any corrections for non-linearity the standard deviation of the error is 9 mum (2.2%). Using a simple analytical expression and a 2-d correction-function stored in a look-up table the positioning error is reduced to 6 (1.5%) and 2 (0.5%) mum, respectively.
  •  
5.
  • Niskanen, Ilpo, et al. (författare)
  • Determination of nanoparticle size using Rayleigh approximation and Mie theory
  • 2019
  • Ingår i: Chemical Engineering Science. - : Elsevier. - 0009-2509 .- 1873-4405. ; 201, s. 222-229
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurate determination of the size of nanoparticles has an important role in many different scientific and industrial purposes, such as in material, medical and environment sciences, colloidal chemistry and astrophysics. We describe an effective optical method to determine the size of nanoparticles by analysis of transmission and scattering of visible spectral range data from a designed UV-Vis multi-spectrophotometer. The size of the nanoparticles was calculated from the extinction cross section of the particles using Rayleigh approximation and Mie theory. We validated the method using polystyrene nanospheres, cellulose nanofibrils, and cellulose nanocrystals. A good agreement was achieved through graphical analysis between measured extinction cross section values and theoretical Rayleigh approximation and Mie theory predictions for the sizes of polystyrene nanospheres at wavelength range 450-750 nm. Provided that Rayleigh approximation's forward scattering (FS)/back scattering (BS) ratio was smaller than 1.3 and Mie theory's FS/BS ratio was smaller than 1.8. A good fit for the hydrodynamic diameter of nanocellulose was achieved using the Mie theory and Rayleigh approximation. However, due to the high aspect ratio of nanocellulose, the obtained results do not directly reflect the actual cross-sectional diameters of the nanocellulose. Overall, the method is a fast, relatively easy, and simple technique to determine the size of a particle by a spectrophotometer. Consequently, the method can be utilized for example in production and quality control purposes as well as for research and development applications.
  •  
6.
  • Niskanen, Ilpo, et al. (författare)
  • Determination of relative solids concentration in homogeneous dual component pulp-filler suspension by multi-spectrophotometer
  • 2020
  • Ingår i: Nordic Pulp & Paper Research Journal. - : Walter de Gruyter GmbH. - 0283-2631 .- 2000-0669. ; 35:1, s. 71-77
  • Tidskriftsartikel (refereegranskat)abstract
    • The concentration of fibers and fillers in the pulp suspension is an important parameter in the monitoring process. This paper proposes a versatile optical measurement system to estimate the concentration of a solids mixture in water. The geometry used in a multi-spectrophotometer (MSM) enables the controlled observation of transmission, and forward scattering light from the suspension in the UV-visible spectral range. We have developed the new fibers mixing system which gives a homogenous distribution of the fines and fillers making it possible to increase the reproducibility and accuracy of the measurement. The data analysis is based on the Beer-Lambert law and CIELAB color space equations. The results show that the proposed method is accurate for measuring the fines and filler concentrations in multicomponent suspensions. 
  •  
7.
  • Reifarth, R., et al. (författare)
  • Nuclear astrophysics with radioactive ions at FAIR
  • 2016
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 665:1
  • Konferensbidrag (refereegranskat)abstract
    • The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process beta-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.
  •  
8.
  • Thungström, Göran, et al. (författare)
  • Fabrication and Characterization of thin delta E-Detectors for Spectroscopic Application
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 546:1-2, s. 312-318
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultra thin delta E-detectors for spectroscopic applications have been fabricated and characterized down to a thickness of 4.5 μm. A common one-side mask aligner was in use to fabricate the detectors. The detectors display low leakage current and the resulting capacitance is close to the detector window capacitance below a threshold voltage. The detector telescope should be slightly tilted to reduce the probability for channeling. However, even better control of the thickness uniformity is needed to improve the resolution in the E-E detector telescope
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy