SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:uu ;lar1:(cth);pers:(Hajdu Janos)"

Sökning: LAR1:uu > Chalmers tekniska högskola > Hajdu Janos

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bielecki, Johan, 1982, et al. (författare)
  • Electrospray sample injection for single-particle imaging with x-ray lasers
  • 2019
  • Ingår i: Science advances. - : American Association for the Advancement of Science (AAAS). - 2375-2548. ; 5:5
  • Tidskriftsartikel (refereegranskat)abstract
    • The possibility of imaging single proteins constitutes an exciting challenge for x-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available x-ray lasers and, as we demonstrate here, contamination of the aerosolized molecules by nonvolatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet size during aerosolization. Here, we show that, with our electrospray injector, we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next-generation x-ray lasers, constitute an important stepping stone toward the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.
  •  
2.
  • Gorkhover, Tais, et al. (författare)
  • Femtosecond X-ray Fourier holography imaging of free-flying nanoparticles
  • 2018
  • Ingår i: Nature Photonics. - : Springer Science and Business Media LLC. - 1749-4885 .- 1749-4893. ; 12:3, s. 150-153
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultrafast X-ray imaging on individual fragile specimens such as aerosols 1 , metastable particles 2 , superfluid quantum systems 3 and live biospecimens 4 provides high-resolution information that is inaccessible with conventional imaging techniques. Coherent X-ray diffractive imaging, however, suffers from intrinsic loss of phase, and therefore structure recovery is often complicated and not always uniquely defined 4,5 . Here, we introduce the method of in-flight holography, where we use nanoclusters as reference X-ray scatterers to encode relative phase information into diffraction patterns of a virus. The resulting hologram contains an unambiguous three-dimensional map of a virus and two nanoclusters with the highest lateral resolution so far achieved via single shot X-ray holography. Our approach unlocks the benefits of holography for ultrafast X-ray imaging of nanoscale, non-periodic systems and paves the way to direct observation of complex electron dynamics down to the attosecond timescale.
  •  
3.
  • Hantke, Max Felix, et al. (författare)
  • Rayleigh-scattering microscopy for tracking and sizing nanoparticles in focused aerosol beams
  • 2018
  • Ingår i: IUCrJ. - 2052-2525. ; 5, s. 673-680
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultra-bright femtosecond X-ray pulses generated by X-ray free-electron lasers (XFELs) can be used to image high-resolution structures without the need for crystallization. For this approach, aerosol injection has been a successful method to deliver 70-2000 nm particles into the XFEL beam efficiently and at low noise. Improving the technique of aerosol sample delivery and extending it to single proteins necessitates quantitative aerosol diagnostics. Here a lab-based technique is introduced for Rayleigh-scattering microscopy allowing us to track and size aerosolized particles down to 40 nm in diameter as they exit the injector. This technique was used to characterize the 'Uppsala injector', which is a pioneering and frequently used aerosol sample injector for XFEL single-particle imaging. The particle-beam focus, particle velocities, particle density and injection yield were measured at different operating conditions. It is also shown how high particle densities and good injection yields can be reached for large particles (100-500 nm). It is found that with decreasing particle size, particle densities and injection yields deteriorate, indicating the need for different injection strategies to extend XFEL imaging to smaller targets, such as single proteins. This work demonstrates the power of Rayleigh-scattering microscopy for studying focused aerosol beams quantitatively. It lays the foundation for lab-based injector development and online injection diagnostics for XFEL research. In the future, the technique may also find application in other fields that employ focused aerosol beams, such as mass spectrometry, particle deposition, fuel injection and three-dimensional printing techniques.
  •  
4.
  • Klimešová, Eva, et al. (författare)
  • Plasma channel formation in NIR laser-irradiated carrier gas from an aerosol nanoparticle injector
  • 2019
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 9:1
  • Tidskriftsartikel (refereegranskat)abstract
    • © 2019, The Author(s). Aerosol nanoparticle injectors are fundamentally important for experiments where container-free sample handling is needed to study isolated nanoparticles. The injector consists of a nebuliser, a differential pumping unit, and an aerodynamic lens to create and deliver a focused particle beam to the interaction point inside a vacuum chamber. The tightest focus of the particle beam is close to the injector tip. The density of the focusing carrier gas is high at this point. We show here how this gas interacts with a near infrared laser pulse (800 nm wavelength, 120 fs pulse duration) at intensities approaching 1016 Wcm−2. We observe acceleration of gas ions to kinetic energies of 100s eV and study their energies as a function of the carrier gas density. Our results indicate that field ionisation by the intense near-infrared laser pulse opens up a plasma channel behind the laser pulse. The observations can be understood in terms of a Coulomb explosion of the created underdense plasma channel. The results can be used to estimate gas background in experiments with the injector and they open up opportunities for a new class of studies on electron and ion dynamics in nanoparticles surrounded by a low-density gas.
  •  
5.
  • Lundholm, Ida V., et al. (författare)
  • Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging
  • 2018
  • Ingår i: IUCrJ. - : International Union of Crystallography. - 2052-2525. ; 5, s. 531-541
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.
  •  
6.
  • Mühlig, Kerstin, et al. (författare)
  • Nanometre-sized droplets from a gas dynamic virtual nozzle
  • 2019
  • Ingår i: Journal of Applied Crystallography. - : INT UNION CRYSTALLOGRAPHY. - 1600-5767 .- 0021-8898. ; 52, s. 800-808
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports on improved techniques to create and characterize nanometre-sized droplets from dilute aqueous solutions by using a gas dynamic virtual nozzle (GDVN). It describes a method to measure the size distribution of uncharged droplets, using an environmental scanning electron microscope, and provides theoretical models for the droplet sizes created. The results show that droplet sizes can be tuned by adjusting the gas and liquid flow rates in the GDVN, and at the lowest liquid flow rates, the size of the water droplets peaks at about 120 nm. This droplet size is similar to droplet sizes produced by electrospray ionization but requires neither electrolytes nor charging of the solution. The results presented here identify a new operational regime for GDVNs and show that predictable droplet sizes, comparable to those obtained by electrospray ionization, can be produced by purely mechanical means in GDVNs.
  •  
7.
  • Pietrini, Alberto, et al. (författare)
  • A statistical approach to detect protein complexes at X-ray free electron laser facilities
  • 2018
  • Ingår i: Communications Physics. - : Springer Science and Business Media LLC. - 2399-3650. ; 1
  • Tidskriftsartikel (refereegranskat)abstract
    • The Flash X-ray Imaging (FXI) technique, under development at X-ray free electron lasers (XFEL), aims to achieve structure determination based on diffraction from individual macromolecular complexes. We report an FXI study on the first protein complex-RNA polymerase II-ever injected at an XFEL. A successful 3D reconstruction requires a high number of observations of the sample in various orientations. The measured diffraction signal for many shots can be comparable to background. Here we present a robust and highly sensitive hit-identification method based on automated modeling of beamline background through photon statistics. It can operate at controlled false positive hit-rate of 3 x10(-5). We demonstrate its power in determining particle hits and validate our findings against an independent hit-identification approach based on ion time-of-flight spectra. We also validate the advantages of our method over simpler hit-identification schemes via tests on other samples and using computer simulations, showing a doubled hit-identification power.
  •  
8.
  • Vinko, S. M., et al. (författare)
  • Time-Resolved XUV Opacity Measurements of Warm Dense Aluminum
  • 2020
  • Ingår i: Physical Review Letters. - : American Physical Society. - 1079-7114 .- 0031-9007. ; 124:22
  • Tidskriftsartikel (refereegranskat)abstract
    • The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperature-dependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order of the Fermi energy. Plasma heating and opacity enhancement are observed on ultrafast timescales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm dense matter.
  •  
9.
  • Wiedorn, Max O., et al. (författare)
  • Megahertz serial crystallography
  • 2018
  • Ingår i: Nature Communications. - : Nature Publishing Group. - 2041-1723. ; 9
  • Tidskriftsartikel (refereegranskat)abstract
    • The new European X-ray Free-Electron Laser is the first X-ray free-electron laser capable of delivering X-ray pulses with a megahertz inter-pulse spacing, more than four orders of magnitude higher than previously possible. However, to date, it has been unclear whether it would indeed be possible to measure high-quality diffraction data at megahertz pulse repetition rates. Here, we show that high-quality structures can indeed be obtained using currently available operating conditions at the European XFEL. We present two complete data sets, one from the well-known model system lysozyme and the other from a so far unknown complex of a beta-lactamase from K. pneumoniae involved in antibiotic resistance. This result opens up megahertz serial femtosecond crystallography (SFX) as a tool for reliable structure determination, substrate screening and the efficient measurement of the evolution and dynamics of molecular structures using megahertz repetition rate pulses available at this new class of X-ray laser source.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy