SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:uu ;lar1:(rkh);mspu:(chapter)"

Sökning: LAR1:uu > Röda Korsets Högskola > Bokkapitel

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Stridh, Sara, et al. (författare)
  • C-peptide normalizes glomerular filtration rate in hyperfiltrating conscious diabetic rats
  • 2009
  • Ingår i: Oxygen transport to tissue xxx. - New York : Springer. - 9780387859972 - 0387859977 - 9780387859989 ; , s. 219-225
  • Bokkapitel (refereegranskat)abstract
    • Tubular electrolyte transport accounts for a major part of the oxygen consumed by the normal kidney. We have previously reported a close association between diabetes and increased oxygen usage, partly due to increased tubular electrolyte transport secondary to glomerular hyperfiltration during the early onset of diabetes. Several studies have shown that acute administration of C-peptide to diabetic rats with glomerular hyperfiltration results in normalized glomerular filtration rate (GFR). In this study, we validated a novel method for precise and repetitive GFR measurements in conscious rats and used C-peptide injection in diabetic rats for evaluation. First, GFR was determined in normoglycemic control rats before and after C-peptide administration. Thereafter, all rats were made diabetic by an i.v. streptozotocin injection. Fourteen days later, GFR was again determined before and after C-peptide administration. GFR was estimated from plasma clearance curves using a single bolus injection of FITC-inulin, followed by serial blood sampling over 155 min. FITC-inulin clearance was calculated using non-compartmental pharmacokinetic data analysis. Baseline GFR in normoglycemic controls was 2.10 +/- 0.18 ml/min, and was unaffected by C-peptide (2.23 +/- 0.14 ml/min). Diabetic rats had elevated GFR (3.06 +/- .034 ml/min), which was normalized by C-peptide (2.35 +/- 0.30 ml/min). In conclusion, the used method for estimation of GFR in conscious animals result in values that are in good agreement with those obtained from traditional GFR measurements on anaesthetized rats. However, multiple measurements from the same conscious subject can be obtained using this method. Furthermore, as previously shown on anaesthetized rats, C-peptide also normalizes GFR in hyperfiltrating conscious diabetic rats.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy