SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "LAR1:uu ;pers:(Larsson Rolf);pers:(Larsson Anders)"

Sökning: LAR1:uu > Larsson Rolf > Larsson Anders

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Christensen, Kjeld, et al. (författare)
  • Effects on blood compatibility in vitro by combining a direct P2Y(12) receptor inhibitor and heparin coating of stents
  • 2006
  • Ingår i: Platelets. - 0953-7104. ; 17:5, s. 318-327
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of the direct platelet P2Y12 receptor inhibitor, AR-C69931MX, on activation of blood induced by stents with and without heparin coating was investigated using a whole blood Chandler loop model in vitro . Stents were deployed in Chandler loops. Fresh human blood with heparin and AR-C69931MX was rotated for 1 h at 37°C and used for measurements of platelets, microparticles, thrombin-antithrombin complex (TAT), fibrinogen binding to platelets, P-selectin expression by platelets, CD11b, Prothrombin Fragment F1+2, FXIa-AT, FXIIa-AT, C3a, sC5b-9 and stent score. In the first experiment there were four study groups with unmodified stents: 1a, no AR-C69931MX; 1b, 250 nmol/L; 1c, 750 nmol/L; 1d, 2250 nmol/L of AR-C69931MX. In the second experiment the concentration of AR-C69931MX was 500 nmol/L: 2a; tubings without stent; 2b; tubings with heparin-coated stent; 2c; tubings with unmodified stents. Heparin-coated stents were used in the third experiment: 3a; no AR-C69931MX; 3b; 500 nmol/L of AR-C69931MX. In the first experiment there were significant differences in all parameters analysed except for C3a, and stent score when the group with no AR-C69931MX was compared to all the groups with AR-C69931MX. In the second experiment there were significant differences in platelet count, TAT, FXIa-AT, FXIIa-AT and stent score when unmodified stents were compared to loops with no stents and partly to loops with heparin-coated stents. In the third experiment there was a significant reduction in generation of TAT, stent score and better preservation of platelet number by combining the platelet inhibitor and heparin-coated stents as compared to heparin-coated stents alone. The conclusion is that the direct P2Y12 receptor inhibitor AR-C69931MX reduced the different aspects of activation of blood induced by both unmodified and heparin-coated stents.
  •  
2.
  •  
3.
  •  
4.
  • Johnell, Matilda, et al. (författare)
  • Coagulation, fibrinolysis and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting using a new heparin-coated surface
  • 2002
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - 0022-5223. ; 124:2, s. 321-332
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Heparin coating of the cardiopulmonary bypass circuit is shown to improve the biocompatibility of the surface. We have studied a new heparin surface, the Corline Heparin Surface, applied to a complete set of an extracorporeal device used during coronary artery bypass grafting in terms of activation of inflammation, coagulation, and fibrinolysis in patients and in shed mediastinal blood.METHODS: Sixty patients scheduled for coronary artery bypass grafting were randomized to one of 3 groups with heparin-coated devices receiving either a standard, high, or low dose of systemic heparin or to an uncoated but otherwise identical circuit receiving a standard dose of systemic heparin. Samples were drawn before, during, and after the operation from the pericardial cavity and in shed mediastinal blood. No autotransfusion of shed mediastinal blood was performed.RESULTS: The Corline Heparin Surface significantly reduced the activation of coagulation, fibrinolysis, platelets, and inflammation compared with that seen with the uncoated surface in combination with a standard dose of systemic heparin during cardiac surgery with cardiopulmonary bypass. Both a decrease and an increase of systemic heparin in combination with the coated heparin surface resulted in higher activation of these processes. A significantly higher expression of all studied parameters was found in the shed mediastinal blood compared with in systemic blood at the same time.CONCLUSIONS: The Corline Heparin Surface used in cardiopulmonary bypass proved to be more biocompatible than an uncoated surface when using a standard systemic heparin dose. The low dose of systemic heparin might not be sufficient to maintain the antithrombotic activity, and the high dose resulted in direct cell activation rather than a further anti-inflammatory and anticoagulatory effect.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4
 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy