1.
  • Arvidson, Magnus, et al. (författare)
  • Measurement of the efficiency of a water spray system against diesel oil pool and spray fires
  • 2005
  • Rapport (refereegranskat)abstract
    • Simple and robust test methodologies that make it possible to measure and quantify the effectiveness of water spray or water mist systems intended for ‘large’ shipboard machinery spaces were investigated. Heat Release Rate calorimetry is usually the best method to measure the effectiveness of a water spray or mist system, although not all fire laboratories have access to such equipment. Therefore, there is a need to explore if other traditional measurement techniques can be used. Such methods include thermocouples, heat flux gages and Plate Thermometers. An additional method, the Pipe Thermometer, has been developed and investigated within the project. It consists of an insulated thin-walled stainless steel tube having an outer diameter of 103 mm with numerous thermocouples welded on the outside surface. The study, which was applied here on a water spray system, shows that the Pipe Thermometer is a possible method to use for evaluation of the efficiency of such system. It is definitely a better method than using heat flux meters or Plate Thermometer which were located at a distance from the fire source. The best correspondence between the measured data below the water spray system and the measured heat release rate was found between the measured gas temperature data and the measured convective heat release data. Consequently, there is no clear advantage of using the Pipe Thermometer (as mounted here) instead of traditional thermocouples at similar locations.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Claesson, Alexander, et al. (författare)
  • Laboratory fire experiments with a 1/3 train carriage mockup
  • 2012
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • A total of six fire tests were conducted in a mock-up of a subway carriage that is about 1/3 of a full wagon length. They were carried out under a large scale calorimeter in a laboratory environment. The aim of the tests was to investigate the initial fire growth in a corner scenario using different types of ignition sources that could lead to a flashover situation. The ignition sources used were either a wood crib placed on a corner seat or one liter of petrol poured on the corner seat and the neighboring floor together with a backpack. The amount of luggage and wood cribs in the neighborhood of the ignition source was continuously increased in order to identify the limits for flashover in the test-setup. The tests showed that the combustible boards on parts of the walls had a significant effect on the fire spread. In the cases where the initial fire did not exceed a range of 400 – 600 kW no flashover was observed. If the initial fire grew up to 700 – 900 kW a flashover was observed. The maximum heat release rate during a short flashover period for this test set-up was about 3.5 MW. The time to reach flashover was highly dependent on the ignition type, wood cribs or backpack and petrol.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Gehandler, Jonatan, et al. (författare)
  • Principer och strategier för ventilation vid brand i undermarksanläggningar
  • 2018
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • The report describes different underground systems including mines and tunnels during construction (tunneling). The key factors that affect fire development in underground systems are described. Proposal and recommendations for ventilation strategies in case of fire are given. The report covers both fuel- and ventilation-controlled fires. In general, a minimal ventilation limits the fire growth and may even inert the fire through ascended smoke. A minimal ventilation also contributes to improved conditions for a first fire extinguishing attempt and evacuation.
  •  