SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Adams Judith E.) ;lar1:(mau);pers:(Berkas L)"

Search: WFRF:(Adams Judith E.) > Malmö University > Berkas L

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Lindh, Christina, et al. (author)
  • Mandibular cortical index for osteoporosis diagnosis : the OSTEODENT project
  • 2006
  • Conference paper (peer-reviewed)abstract
    • Objectives: to determine the diagnostic validity of the mandibular cortical index (MCI) for the diagnosis of osteoporosis in peri- and post-menopausal women. Methods: Volunteer female subjects in the 45 to 70 year age band, recruited from four European centres, underwent dual x-ray energy absorptiometry of the hip and lumbar spine, to provide a gold standard diagnosis of osteoporosis, and a DPR examination. Five observers, all oral radiologists but of different experience, made an assessment of porosity of the cortex of the lower border of the mandible using MCI. Results: Data of 661 subjects (mean age 54.8y; sd = 6.19y) were available for analysis, with 140 (21.2%) being classified as having osteoporosis. MCI data for each observer were dichotomosed so that MCI grade 3 indicated a positive test result and grades 1 and 2 a negative test result. The sensitivities and specificties of MCI for osteoporosis diagnosis were determined: Osteoporosis at any site Osteoporosis at femoral neck Observer Sensitivity (%) Specificity (%) Sensitivity (%) Specificity (%) 1 24.8 93.3 27.3 91.3 2 23.4 93.2 24.2 91.3 3 23.4 91.5 24.2 89.8 4 20.6 99.8 22.7 91.8 5 19.1 91.1 22.7 90.3 Interobserver repeatability (using weighted Kappa) showed a range of 0.183 to 0.780, with a median value of 0.467. This median indicated moderate agreement. Conclusions: MCI had low sensitivity but high specificity for diagnosis of osteoporosis. This high specificity might prove to be more appropriate for use in primary dental care than using a different diagnostic threshold. This work was supported by a research and technological development project grant from the European Commission FP5 'Quality of Life and Management of Living Resources' (QLK6-2002-02243).
  •  
2.
  • Lindh, Christina, et al. (author)
  • ROC analysis of directly measured mandibular cortical width from panoramic radiogarphs for diagnosis of osteoporosis : the OSTEODENT study
  • 2006
  • Conference paper (peer-reviewed)abstract
    • Objectives: To determine the diagnostic validity of the width of the inferior mandibular cortex on dental panoramic radiographs (DPRs), as measured directly by observers, for the diagnosis of osteoporosis in peri- and post-menopausal women. Methods: Volunteer female subjects in the 45 to 70 year age band, recruited from four European centres, underwent dual x-ray energy absorptiometry of the hip and lumbar spine, to provide a gold standard diagnosis of osteoporosis, and a DPR examination. Five observers, all oral radiologists but of different experience, made manual measurements of width of the mandibular lower border cortex below the mental foramina bilaterally. Results: Data of 661 subjects (mean age 54.8y; sd = 6.19y) were available for analysis, with 140 (21.2%) being classified as having osteoporosis. Az values are given below: Osteoporosis at any site Osteoporosis at femoral neck Observer Az (se) 95% CI Az (se) 95% CI 1 0.782 0.748-0.813 0.804 0.771-0.833 2 0.766 0.731-0.799 0.757 0.722-0.791 3 0.756 0.721-0.788 0.790 0.757-0.821 4 0.746 0.711-0.779 0.762 0.727-0.794 5 0.710 0.673-0.744 0.752 0.718-0.785 A diagnostic threshold of 3mm resulted in a sensitivity of 50.7% and a specificity of 80.4% (data for median observer, 2). Mean within-subject variance for the five observers was 0.126mm (sd = 0.355mm). Repeatability is the difference between two measurements made by any pair of observers for the same subject and was expected to be less than 0.983 mm for 95% of pairs of observations. Conclusions: Direct measurement of mandibular cortical width was diagnostically effective in diagnosis of osteoporosis. However, repeatability may be a problem in clinical use. This work was supported by a research and technological development project grant from the European Commission FP5 'Quality of Life and Management of Living Resources' (QLK6-2002-02243).
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
conference paper (2)
Type of content
peer-reviewed (2)
Author/Editor
Jacobs, R. (2)
Lindh, Christina (2)
Horner, K (2)
Mitsea, A (2)
Adams, Judith (2)
Karayianni, K (2)
show more...
van der Stelt, P (2)
Harisson, E (2)
Pavitt, S (2)
Devlin, H (2)
Mastoris, M (2)
Tsiklakis, K (1)
show less...
University
Language
English (2)
Research subject (UKÄ/SCB)
Medical and Health Sciences (2)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view