SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ahnesjö Jonas)
 

Sökning: WFRF:(Ahnesjö Jonas) > Ahnesjö Anders Professor > Ion recombination i...

Ion recombination in liquid ionization chambers : development of an experimental method to quantify general recombination

Andersson, Jonas, 1975- (författare)
Umeå universitet,Radiofysik
Tölli, Heikki, Filosofie doktor (preses)
Umeå universitet,Radiofysik
Johansson, Lennart (preses)
visa fler...
Ahnesjö, Anders, Professor (opponent)
Uppsala universitet
visa färre...
 (creator_code:org_t)
ISBN 9789174596076
Umeå : Umeå universitet, 2013
Engelska 76 s.
Serie: Umeå University medical dissertations, 0346-6612 ; 1567
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • An experimental method (the two-dose-rate method) for the correction of general recombination losses in liquid ionization chambers has been developed and employed in experiments with different liquids and radiation qualities. The method is based on a disassociation of initial and general recombination, since an ionized liquid is simultaneously affected by both of these processes.The two-dose-rate method has been compared to an existing method for general recombination correction for liquid ionization chambers, and has been found to be the most robust method presently available.The soundness of modelling general recombination in liquids on existing theory for gases has been evaluated, and experiments indicate that the process of general recombination is similar in a gas and a liquid. It is thus reasonable to employ theory for gases in the two-dose-rate method to achieve experimental corrections for general recombination in liquids. There are uncertainties in the disassociation of initial and general recombination in the two-dose-rate method for low applied voltages, where initial recombination has been found to cause deviating results for different liquids and radiation qualities.Sensitivity to ambient electric fields has been identified in the microLion liquid ionization chamber (PTW, Germany). Experimental data may thus be perturbed if measurements are conducted in the presence of ambient electric fields, and the sensitivity has been found to increase with an increase in the applied voltage. This can prove to be experimentally limiting since general recombination may be too severe for accurate corrections if the applied voltage is low.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

General recombination
initial recombination
liquid ionization chamber
radiation dosimetry
radiofysik
radiation physics

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy