SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ale Iris) srt2:(2017);lar1:(lu);pers:(Matsunaga Kayoko)"

Search: WFRF:(Ale Iris) > (2017) > Lund University > Matsunaga Kayoko

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Engfeldt, Malin, et al. (author)
  • Multicenter patch testing with methylchloroisothizoline/methylisothiazolinone in 100 and 200 ppm within the international contact dermatitis research group
  • 2017
  • In: Dermatitis. - 1710-3568. ; 28:3, s. 215-218
  • Journal article (peer-reviewed)abstract
    • Background: The preservative methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a well-known contact sensitizer. Historically, there have been different opinions on the optimal patch test concentration of MCI/MI, and both 0.01% and 0.02% aqueous (aq.) have been proposed. In 2011, based on literature reviews, it was recommended that the concentration of 0.02% aq. should be used in the international baseline series. Objectives: The aim of this study was to verify the recommendation from 2011 by comparing the patch test results from consecutive patch testing with MCI/MI 0.01% and 0.02% in clinics representing countries around the world. Patients and Methods: Two thousand seven hundred three consecutive patients with dermatitis in 8 dermatology clinics representing 8 countries were patch tested with MCI/MI 0.01% aq. and, in parallel with MCI/MI 0.02% aq., provisionally included in the baseline series. Results: Contact allergy to MCI/MI at 0.01% and 0.02% was found in 3.7% and 5.6% of the patients, respectively (P G 0.001). Conclusions: Methylchloroisothiazolinone/MI 0.02% aq. (dose, 6 Kg/cm2) diagnoses significantly more contact allergy than 0.01% (dose, 3 Kg/cm2), without resulting in more adverse reactions.Methylchloroisothiazolinone/MI at 0.02% aq. should therefore be continuously used in the international baseline series.
  •  
2.
  • Isaksson, Marléne, et al. (author)
  • Multicenter patch testing with methylisothiazolinone and methylchloroisothiazolinone/methylisothiazolinone within the international contact dermatitis research group
  • 2017
  • In: Dermatitis. - 1710-3568. ; 28:3, s. 210-214
  • Journal article (peer-reviewed)abstract
    • Background: The preservatives methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI are well-known contact sensitizers. Recently, an increase in the contact allergy frequency for MI 0.2% aqueous (aq) has been seen in many European countries paralleled with an increase in MCI/MI allergy. Many of the MI-allergic patients do not react to MCI/MI 0.01% or 0.02% because the concentration of MI in these preparations is too low (25 and 50 ppm, respectively) to elicit a positive patch test reaction. Objectives: The aims of this study were to investigate the prevalence of contact allergy to MI in the participating clinics representing various countries all over the world, to assess how many additional individuals with contact allergy are found by testing MI 0.2% aq in parallel with MCI/MI 0.02%, and to assess the clinical relevance of MI and MCI/MI allergies. Patients and Methods: In 9 dermatology clinics representing 9 countries, 3865 consecutive patients with dermatitis were patch tested with MI 0.2% aq and in parallel with MCI/MI 0.02% aq, provisionally included into the baseline series. An assessment of clinical relevance in those allergic to MI was also made. Results: Contact allergy to MI was found in 284 patients (7.3%). The frequency of contact allergy varied from 0.8% to 10.9% in different centers. Simultaneous reactivity to 200 ppm of MCI/MI was found in 67.3% of the MI-positive patients. Contact allergy to MI alone without any simultaneous contact allergy to 200 ppm of MCI/MI was diagnosed in 93 patients (32.7%; 2.4% of all tested patients). The contact allergy to MI and/or MCI/MI could explain or contribute to dermatitis in more than 60% of the MI-allergic patients. Conclusions: Methylisothiazolinone of 2000 ppm needs to be patch tested on its own to not miss contact allergy.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
journal article (2)
Type of content
peer-reviewed (2)
Author/Editor
Bruze, Magnus (2)
Goossens, An (2)
Andersen, Klaus E (2)
Ale, Iris (2)
Goh, Chee Leok (2)
Elsner, Peter (2)
show more...
Jerajani, Hemangi (2)
Isaksson, Marléne (1)
McFadden, John (1)
Engfeldt, Malin (1)
show less...
University
Language
English (2)
Research subject (UKÄ/SCB)
Medical and Health Sciences (2)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view