    • Objectives: We examined the association between obesity and early-onset cryptogenic ischemic stroke (CIS) and whether fat distribution or sex altered this association. Materials and Methods: This prospective, multi-center, case-control study included 345 patients, aged 18-49 years, with first-ever, acute CIS. The control group included 345 age- and sex-matched stroke-free individuals. We measured height, weight, waist circumference, and hip circumference. Obesity metrics analyzed included body mass index (BMI), waist-to-hip ratio (WHR), waist-to-stature ratio (WSR), and a body shape index (ABSI). Models were adjusted for age, level of education, vascular risk factors, and migraine with aura. Results: After adjusting for demographics, vascular risk factors, and migraine with aura, the highest tertile of WHR was associated with CIS (OR for highest versus lowest WHR tertile 2.81, 95%CI 1.43-5.51; P=0.003). In sex-specific analyses, WHR tertiles were not associated with CIS. However, using WHO WHR cutoff values (>0.85 for women, >0.90 for men), abdominally obese women were at increased risk of CIS (OR 2.09, 95%CI 1.02-4.27; P=0.045). After adjusting for confounders, WC, BMI, WSR, or ABSI were not associated with CIS. Conclusions: Abdominal obesity measured with WHR was an independent risk factor for CIS in young adults after rigorous adjustment for concomitant risk factors. © 2022 The Author(s)
  •  
2.
  • Bech-Hanssen, O, et al. (författare)
  • Aortic prosthetic valve design and size : Relation to Doppler echocardiographic findings and pressure recovery - An in vitro study
  • 2000
  • Ingår i: Journal of the American Society of Echocardiography. - 0894-7317 .- 1097-6795. ; 13:1, s. 39-50
  • Tidskriftsartikel (refereegranskat)abstract
    • The extent to which Doppler echocardiography information can be used in the assessment of prosthesis hemodynamic performance is still controversial. The goals of our study were to assess the importance of valve design and size both on Doppler echocardiography findings and on pressure recovery in a fluid mechanics model. We performed Doppler and catheter measurements in the different orifices of the bileaflet St Jude (central and side orifices), the monoleaflet Omnicarbon (major and minor orifices), and the stented Biocor porcine prosthesis. Net pressure gradients were predicted from Doppler flow velocities, assuming either independence or dependence of valve size. The peak Doppler estimated gradients (mean +/- SD for sizes 21 to 27) were 21 +/- 10.3 rum Hg for St Jude, 18 +/- 9.3 mm Hg for Omnicarbon, and 37 +/- 14.5 mm Hg for Biocor (P <.05 for St Jude and Omnicarbon vs Biocor). The pressure recovery (proportion of peak catheter pressure) was 53% +/- 8.6% for central-St Jude, 29% +/- 8.9% for side-St Jude, 20% +/- 5.6% for major-Omnicarbon, 23% +/- 7.4% for minor-Omnicarbon, and 18% +/- 3.6% for Biocor (P <.05 for central-St Jude and side-St Jude vs Omnicarbon and Biocor). Valve sizes (2) significantly influenced pressure recovery (y in percentage) (central-St Jude: y = 3.7x - 35.9, r = 0.88, P =.0001, major-Omnicarbon: y = 2.1x - 30.3, r = 0.85, P =.0001). By assuming dependence of valve size, Doppler was able to predict net pressure gradients in St Jude with a mean difference between net catheter and Doppler-predicted gradient of - 3.8 +/- 2.5 mm Hg. In conclusion, prosthetic value design and size influence the degree of pressure recovery, making Doppler gradients potentially misleading in both the assessment of hemodynamic performance and the comparison of one design with another. The preliminary results indicate that net gradient can be predicted from Doppler gradients,
  •  
3.
  • Bech-Hanssen, O., et al. (författare)
  • Net Pressure Gradients in Aortic Prosthetic Valves can be Estimated by Doppler
  • 2003
  • Ingår i: Journal of the American Society of Echocardiography. - 0894-7317 .- 1097-6795. ; 16:8, s. 858-866
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In aortic prosthetic valves, both the Doppler-estimated gradients and orifice areas are misleading in the assessment of hemodynamic performance. The parameter of major interest is the net pressure gradient after pressure recovery (PR). We, therefore, investigated, in vitro, our ability to predict the net pressure gradient and applied the formulas in a representative patient population with 2 different valve designs. Methods: We studied the St Jude Medical (SJM) standard valve (size 19-27) and SJM Biocor (size 21-27) in an in vitro steady-flow model with simultaneous Doppler-estimated pressure and catheter pressure measurements. Using echocardiography, we also studied patients who received the SJM (n = 66) and SJM Biocor (n = 45). Results: In the SJM, we observed PR both within the prosthesis and aorta, whereas in the SJM Biocor, PR was only present in the aorta. We estimated the PR within the valve and within the aorta separately from echocardiographic in vitro data, combining a regression equation (valve) with an equation on the basis of fluid mechanics theory (aorta). The difference between estimated and catheter-obtained net gradients (mean ± SD) was 0.6 ± 1.6 mm Hg in the SJM and - 0.2 ± 1.9 mm Hg in the SJM Biocor. When these equations were applied in vivo, we found that PR had an overall value of 57 ± 7% of the peak Doppler gradient in the SJM and 33 ± 9% in the SJM Biocor. Conclusions: The in vitro results indicate that it is possible to predict the net pressure gradient by Doppler in bileaflet and stented biologic valves. Our data indicate that important PR is also present in stented biologic valves.
  •  
4.
  •  
5.
  • Poller, Angela, 1988, et al. (författare)
  • Inter- and intra-observer variability in the echocardiographic evaluation of wall motion abnormality in patients with ST-elevation myocardial infarction or takotsubo syndrome - A novel approach
  • 2023
  • Ingår i: Echocardiography-a Journal of Cardiovascular Ultrasound and Allied Techniques. - 0742-2822. ; 40:7, s. 711-719
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction and ObjectivesUsing existing transthoracic echocardiographic indices to quantify left ventricular wall motion abnormalities (WMAs) can be difficult due to the variations in the location of the abnormalities within the left ventricle, the quality of examinations, and the inter-/intra-observer variability of available indices. This study aimed to evaluate a new approach for measuring the extent of WMA by calculating the percentage of abnormal wall motion and comparing it to the wall motion score index (WMSI). The study also sought to assess inter- and intra-observer variability. MethodsThe study included 140 echocardiograms from 54 patients presenting with ST-elevation myocardial infarction or Takotsubo syndrome. All patients underwent an echocardiographic examination according to a standard protocol and the images were used to measure the extent of akinesia (proportion akinesia, PrA), akinesia and hypokinesia (proportion akinesia/hypokinesia, PrAH), and WMSI. The inter-observer variability between the two operators was analyzed. The intra-observer analysis was performed by one observer using the same images at least 1 month after the first measurement. The agreement was analyzed using the Pearson correlation coefficient and Bland-Altman plots. ResultsInter- and intra-observer variability for PrA and PrAH were low and comparable to those for WMSI. ConclusionPrA and PrAH are reliable and reproducible echocardiographic methods for the evaluation of left ventricular wall motion.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy