SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Becker T) ;lar1:(miun)"

Sökning: WFRF:(Becker T) > Mittuniversitetet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Zelenika, S., et al. (författare)
  • Energy harvesting technologies for structural health monitoring of airplane components—a review
  • 2020
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 20:22
  • Tidskriftsartikel (refereegranskat)abstract
    • With the aim of increasing the efficiency of maintenance and fuel usage in airplanes, structural health monitoring (SHM) of critical composite structures is increasingly expected and required. The optimized usage of this concept is subject of intensive work in the framework of the EU COST Action CA18203 “Optimising Design for Inspection” (ODIN). In this context, a thorough review of a broad range of energy harvesting (EH) technologies to be potentially used as power sources for the acoustic emission and guided wave propagation sensors of the considered SHM systems, as well as for the respective data elaboration and wireless communication modules, is provided in this work. EH devices based on the usage of kinetic energy, thermal gradients, solar radiation, airflow, and other viable energy sources, proposed so far in the literature, are thus described with a critical review of the respective specific power levels, of their potential placement on airplanes, as well as the consequently necessary power management architectures. The guidelines provided for the selection of the most appropriate EH and power management technologies create the preconditions to develop a new class of autonomous sensor nodes for the in-process, non-destructive SHM of airplane components.
  •  
2.
  • Mezza, D., et al. (författare)
  • Calibration methods for charge integrating detectors
  • 2022
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 1024
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the introduction of the extremely intense X-ray free electron lasers, the need for low noise, high dynamic range and potentially fast charge integrating detectors has increased significantly. Among all the problems that research and development groups have to face in the development of such detectors, their calibration represents one of the most challenging and the collaboration between the detector development and user groups is of fundamental importance. The main challenge is to develop a calibration suite that is capable to test the detector over a wide dynamic range, with a high granularity and a very high linearity, together with a certain radiation tolerance and the possibility to well define the timings and the synchronization with the detector. Practical considerations have also to be made like the possibility to calibrate the detector in a reasonable time, the availability of the calibration source at the experimental place and so on. Such a calibration test suite is often not represented by a single source but by several sources that can cover different parts of the dynamic range and that need to be cross calibrated to have a final calibration curve. In this respect an essential part of the calibration is also to develop a mathematical model that allows calibrating the entire dynamic range, taking into account features that are calibration source and/or detector specific. The aim of this contribution is to compare the calibration for the AGIPD detector using several calibration sources such as internal current source, backside pulsing, IR pulsed laser, LED light and mono-energetic protons. The mathematical procedure used to calibrate the different sources will be discussed in great detail showing how to take into account a few shortcomings (like pixel coupling) that are common for many charge integrating detectors. This work has been carried out in the frame of the AGIPD project for the European X-ray Free Electron Laser. 
  •  
3.
  • Mezza, D., et al. (författare)
  • Characterization of the AGIPD1.1 readout chip and improvements with respect to AGIPD1.0
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 945
  • Tidskriftsartikel (refereegranskat)abstract
    • AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid detector with a frame rate of 4.5 MHz, a dynamic range up to 104⋅ 12.4 keV photons, as well as single photon resolution, developed for the European XFEL (Eu.XFEL). The final 1 Mpixel detector system consists of 16 tiled modules each one with 16 readout chips. The single ASIC is 64 x 64 pixels, each with a size of 200 x 200 μm2. Each pixel can store up to 352 images. This work is focused on the characterization of AGIPD1.1, the second version of the full scale ASIC, and the improvements with respect to AGIPD1.0. From the measurements presented in this paper we show that the flaws observed in AGIPD1.0 (i.e. ghosting, crosstalk, slow readout speed) have been fixed in AGIPD1.1. In addition the main performance parameters such as noise, dynamic range and so on were measured for the new version of the ASIC and will be summarized. 
  •  
4.
  • Trunk, Ulrich, et al. (författare)
  • AGIPD : A multi megapixel, multi megahertz X-ray camera for the European XFEL
  • 2017
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE - International Society for Optical Engineering. - 9781510611009
  • Konferensbidrag (refereegranskat)abstract
    • AGIPD is a hybrid pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg. It is targeted for use at the European XFEL, a source with unique properties: a train of up to 2700 pulses is repeated at 10 Hz rate. The pulses inside a train are ≤100fs long and separated by 220 ns, containing up to 1012 photons of 12.4 keV each. The readout ASICs with 64 x 64 pixels each have to cope with these properties: Single photon sensitivity and a dynamic range up to 104 photons/pixel in the same image as well as storage for as many as possible images of a pulse train for delayed readout, prior to the next train. The high impinging photon flux also requires a very radiation hard design of sensor and ASIC, which uses 130 nm CMOS technology and radiation tolerant techniques. The signal path inside a pixel of the ASIC consists of a charge sensitive preamplifier with 3 individual gains, adaptively selected by a subsequent discriminator. The preamp also feeds to a correlated double sampling stage, which writes to an analogue memory to record 352 frames. It is random-access, so it can be used most efficiently by overwriting bad or empty images. Encoded gain information is stored to a similar memory. Readout of these memories is via a common charge sensitive amplifier in each pixel, and multiplexers on four differential ports. Operation of the ASIC is controlled via a command interface, using 3 LVDS lines. It also serves to configure the chip's operational parameters and timings.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy