SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bergh Anders) ;hsvcat:2"

Sökning: WFRF:(Bergh Anders) > Teknik

  • Resultat 1-10 av 41
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eklund, Anders, 1965-, et al. (författare)
  • A catheter tactile sensor for measuring hardness of soft tissue : measurement in a silicone model and in an in vitro human prostate model
  • 1999
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 37:5, s. 618-624
  • Tidskriftsartikel (refereegranskat)abstract
    • Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it produces a frequency shift related to the hardness of the object. The aim of this study was to develop an in vitro hardness measurement method using a catheter type version of the sensor. The method was evaluated in an established silicone tissue model and on human prostate tissue in vitro. A linear relationship was found with a high degree of explanation (R2 = 0.98) between a cone penetration hardness standard (DIN ISO 2137) applied to the silicone model and the corresponding frequency shift. The results from measurements on a human prostate tissue sample, fixed with formalin, showed that the relative hardness measured with the tactile sensor correlated (R = -0.96, p < 0.001, N = 60) with the proposed hardness related to the histological composition of the prostate tissue. The results indicated that hardness of prostate tissue, and maybe hardness of human tissue in general, can be expressed according to the cone penetration standard and that the hardness can be measured with this tactile sensory system. These findings hold the promise of further development of a non-invasive tool for hardness measurement in a clinical situation
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Åstrand, Anders, et al. (författare)
  • Prostate cancer detection with a tactile resonance sensor : measurement considerations and clinical setup
  • 2017
  • Ingår i: Sensors. - Switzerland : MDPI AG. - 1424-8220. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Tumors in the human prostate are usually stiffer compared to surrounding non-malignant glandular tissue, and tactile resonance sensors measuring stiffness can be used to detect prostate cancer. To explore this further, we used a tactile resonance sensor system combined with a rotatable sample holder where whole surgically removed prostates could be attached to detect tumors on, and beneath, the surface ex vivo. Model studies on tissue phantoms made of silicone and porcine tissue were performed. Finally, two resected human prostate glands were studied. Embedded stiff silicone inclusions placed 4 mm under the surface could be detected in both the silicone and biological tissue models, with a sensor indentation of 0.6 mm. Areas with different amounts of prostate cancer (PCa) could be distinguished from normal tissue (p < 0.05), when the tumor was located in the anterior part, whereas small tumors located in the dorsal aspect were undetected. The study indicates that PCa may be detected in a whole resected prostate with an uneven surface and through its capsule. This is promising for the development of a clinically useful instrument to detect prostate cancer during surgery.
  •  
6.
  • Nyberg, Morgan, 1971-, et al. (författare)
  • Dual-modality probe intended for prostate cancer detection combining Raman spectroscopy and tactile resonance technology—discrimination of normal human prostate tissues ex vivo
  • 2015
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 39:3, s. 198-207
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common cancer for men in the western world. For the first time, a dual-modality probe, combining Raman spectroscopy and tactile resonance technology, has been used for assessment of fresh human prostate tissue. The study investigates the potential of the dual-modality probe by testing its ability to differentiate prostate tissue types ex vivo. Measurements on four prostates show that the tactile resonance modality was able to discriminate soft epithelial tissue and stiff stroma (p<0.05). The Raman spectra exhibited a strong fluorescent background at the current experimental settings. However, stroma could be discerned from epithelia by integrating the value of the spectral background. Combining both parameters by a stepwise analysis resulted in 100% sensitivity and 91% specificity. Although no cancer tissue was analysed, the results are promising for further development of the instrument and method for discriminating prostate tissues and cancer.
  •  
7.
  • Jalkanen, Ville, et al. (författare)
  • Indentation loading response of a resonance sensor : discriminating prostate cancer and normal tissue
  • 2013
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 37:7, s. 416-423
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common type of cancer among men worldwide. Mechanical properties of prostate tissue are promising for distinguishing prostate cancer from healthy prostate tissue. The aim was to investigate the indentation loading response of a resonance sensor for discriminating prostate cancer tissue from normal tissue. Indentation measurements were done on prostate tissue specimens ex vivo from 10 patients from radical prostatectomy. The measurement areas were analysed using standard histological methods. The stiffness parameter was linearly dependent on the loading force (average R2 = 0.90) and an increased loading force caused a greater stiffness contrast of prostate cancer vs normal tissue. The accuracy of the stiffness contrast was assessed by the ROC curve with the area under the curve being 0.941 for a loading force of 12.8 mN. The results are promising for the development of a resonance sensor instrument for detecting prostate cancer.
  •  
8.
  •  
9.
  •  
10.
  • Candefjord, Stefan, et al. (författare)
  • Combining scanning haptic microscopy and fibre optic Raman spectroscopy for tissue characterization
  • 2012
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 36:6, s. 319-327
  • Tidskriftsartikel (refereegranskat)abstract
    • The tactile resonance method (TRM) and Raman spectroscopy (RS) are promising for tissue characterization in vivo. Our goal is to combine these techniques into one instrument, to use TRM for swift scanning, and RS for increasing the diagnostic power. The aim of this study was to determine the classification accuracy, using support vector machines, for measurements on porcine tissue and also produce preliminary data on human prostate tissue. This was done by developing a new experimental set-up combining micro-scale TRMscanning haptic microscopy (SHM)for assessing stiffness on a micro-scale, with fibre optic RS measurements for assessing biochemical content. We compared the accuracy using SHM alone versus SHM combined with RS, for different degrees of tissue homogeneity. The cross-validation classification accuracy for healthy porcine tissue types using SHM alone was 6581%, and when RS was added it increased to 8187%. The accuracy for healthy and cancerous human tissue was 6770% when only SHM was used, and increased to 7277% for the combined measurements. This shows that the potential for swift and accurate classification of healthy and cancerous prostate tissue is high. This is promising for developing a tool for probing the surgical margins during prostate cancer surgery. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 41
Typ av publikation
konferensbidrag (23)
tidskriftsartikel (16)
doktorsavhandling (1)
licentiatavhandling (1)
Typ av innehåll
refereegranskat (30)
övrigt vetenskapligt/konstnärligt (11)
Författare/redaktör
Bergh, Anders (29)
Lindahl, Olof (17)
Ljungberg, Börje (15)
Lindahl, Olof A. (7)
Ramser, Kerstin (6)
Andersson, Britt M. (6)
visa fler...
Damber, Jan-Erik (4)
Edholm, Bengt (4)
Söderbärg, Anders (4)
Ängquist, Karl-Axel (3)
Eklund, Anders (3)
Lindberg, Peter (3)
Andersson, Britt, 19 ... (3)
Bergh, M. (3)
Tiensuu, Stefan (3)
Olsson, Jörgen (2)
Tulebekova, Saule (2)
Ljungberg, Börje, Pr ... (2)
Bengtsson, Stefan, 1 ... (2)
Bergh, Johan (2)
Nyrud, Anders Q. (2)
Malo, Kjell Arne (2)
Nore, Kristine (2)
McNamee, Robert (2)
Bäcklund, Tomas (2)
Lundström, Anders (2)
Gustavsson, Leif (1)
Olsson, Jörgen, 1966 ... (1)
Dargahi, Bijan (1)
Ericsson, Per, 1968 (1)
Nordin, Annika (1)
Wörman, Anders (1)
Wörman, Anders, Prof ... (1)
Lundmark, Tomas (1)
Ljungberg, Börje, 19 ... (1)
Bergh, Mats, 1968 (1)
Vestling, Lars (1)
Liv, Per, 1979- (1)
Hallberg, Josef (1)
Bisby, Luke (1)
Bäcklund, Ylva (1)
Hyvönen, Riitta (1)
Eklund, Anders, 1965 ... (1)
Bengtsson, Stefan (1)
Bengtsson, S (1)
Jauhiainen, A (1)
Bergh, Mats (1)
Ericsson, Per (1)
Soderbarg, Anders (1)
Ljungberg, Karin (1)
visa färre...
Lärosäte
Luleå tekniska universitet (22)
Umeå universitet (19)
Uppsala universitet (4)
Chalmers tekniska högskola (3)
Kungliga Tekniska Högskolan (2)
Lunds universitet (2)
visa fler...
Mittuniversitetet (2)
Linnéuniversitetet (2)
RISE (2)
Sveriges Lantbruksuniversitet (2)
visa färre...
Språk
Engelska (36)
Svenska (5)
Forskningsämne (UKÄ/SCB)
Lantbruksvetenskap (2)
Naturvetenskap (1)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy