SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bergkvist Leif) ;pers:(Karakatsanis Andreas)"

Sökning: WFRF:(Bergkvist Leif) > Karakatsanis Andreas

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Karakatsanis, Andreas, et al. (författare)
  • Effect of preoperative injection of superparamagnetic iron oxide particles on rates of sentinel lymph node dissection in women undergoing surgery for ductal carcinoma in situ (SentiNot study)
  • 2019
  • Ingår i: British Journal of Surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 106:6, s. 720-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: One-fifth of patients with a preoperative diagnosis of ductal carcinoma in situ (DCIS) have invasive breast cancer (IBC) on definitive histology. Sentinel lymph node dissection (SLND) is performed in almost half of women having surgery for DCIS in Sweden. The aim of the present study was to try to minimize unnecessary SLND by injecting superparamagnetic iron oxide (SPIO) nanoparticles at the time of primary breast surgery, enabling SLND to be performed later, if IBC is found in the primary specimen. Methods: Women with DCIS at high risk for the presence of invasion undergoing breast conservation, and patients with DCIS undergoing mastectomy were included. The primary outcome was whether this technique could reduce SLND. Secondary outcomes were number of SLNDs avoided, detection rate and procedure-related costs. Results: This was a preplanned interim analysis of 189 procedures. IBC was found in 47 and a secondary SLND was performed in 41 women. Thus, 78.3 per cent of patients avoided SLND (P<0.001). At reoperation, SPIO plus blue dye outperformed isotope and blue dye in detection of the sentinel node (40 of 40 versus 26 of 40 women; P<0.001). Costs were reduced by a mean of 24.5 per cent in women without IBC (3990 versus 5286; P<0.001). Conclusion: Marking the sentinel node with SPIO in women having surgery for DCIS was effective at avoiding unnecessary SLND in this study. Registration number: ISRCTN18430240 (http://www.isrctn.com).
  •  
2.
  • Karakatsanis, Andreas, et al. (författare)
  • SentiNot : A way to avoid sentinel node biopsy (SNB) in patients with a preoperative diagnosis of ductal cancer in situ (DCIS)
  • 2017
  • Ingår i: Cancer Research. - Univ Uppsala Hosp, Sect Endocrine & Breast Surg, Uppsala, Sweden. Univ Uppsala Hosp, Uppsala, Sweden. Vastmanland Cty Hosp, Vasteras, Vasteras, Sweden. Uppsala Clin Res Ctr, Uppsala, Sweden. Kalmar Cty Hosp, Sect Breast Surg, Kalmar, Sweden. Univ Uppsala Hosp, Inst Radiol Oncol & Radiotherapy, Uppsala, Sweden. Norrlands Univ Hosp, Umea, Sweden. : AMER ASSOC CANCER RESEARCH. - 0008-5472 .- 1538-7445. ; 77
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  • Karakatsanis, Andreas, et al. (författare)
  • Simplifying Logistics and Avoiding the Unnecessary in Patients with Breast Cancer Undergoing Sentinel Node Biopsy. A Prospective Feasibility Trial of the Preoperative Injection of Super Paramagnetic Iron Oxide Nanoparticles
  • 2018
  • Ingår i: Scandinavian Journal of Surgery. - : SAGE Publications. - 1457-4969 .- 1799-7267. ; 107:2, s. 130-137
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Sentinel node is routinely localized with the intraoperative use of a radioactive tracer, involving challenging logistics. Super paramagnetic iron oxide nanoparticle is a non-radioactive tracer with comparable performance that could allow for preoperative localization, would simplify the procedure, and possibly be of value in axillary mapping before neoadjuvant treatment. The current trial aimed to determine the a priori hypothesis that the injection of super paramagnetic iron oxide nanoparticles in the preoperative period for the localization of the sentinel node is feasible.METHODS: This is a prospective feasibility trial, conducted from 9 September 2014 to 22 October 2014 at Uppsala University Hospital. In all, 12 consecutive patients with primary breast cancer planned for resection of the primary and sentinel node biopsy were recruited. Super paramagnetic iron oxide nanoparticles were injected in the preoperative visit in the outpatient clinic. The radioactive tracer (99mTc) and the blue dye were injected perioperatively in standard fashion. A volunteer was injected with super paramagnetic iron oxide nanoparticles to follow the decline in the magnetic signal in the sentinel node over time. The primary outcome was successful sentinel node detection.RESULTS: Super paramagnetic iron oxide nanoparticles' detection after preoperative injection (3-15 days) was successful in all cases (100%). In the volunteer, axillary signal was presented for 4 weeks. No adverse effects were noted. Conclusion and relevance: Preoperative super paramagnetic iron oxide nanoparticles' injection is feasible and leads to successful detection of the sentinel node. That may lead to simplified logistics as well as the identification, sampling, and marking of the sentinel node in patients planned for neoadjuvant treatment.
  •  
4.
  • Karakatsanis, Andreas, et al. (författare)
  • Superparamagnetic iron oxide nanoparticles as the sole method for sentinel node biopsy detection in patients with breast cancer
  • 2017
  • Ingår i: British Journal of Surgery. - : Oxford University Press (OUP). - 0007-1323 .- 1365-2168. ; 104:12, s. 1675-1685
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Sentinel node biopsy (SNB) using superparamagnetic iron oxide (SPIO) nanoparticles is a novel method in breast cancer. Several studies have verified the non-inferiority of SPIO compared with the standard use of radioisotope (99m) Tc with or without blue dye. The aim of the MONOS study presented here was to evaluate the use of SPIO as a sole tracer and the efficacy of tracer injection in the preoperative setting.METHODS: This prospective cohort study was carried out in two hospitals, one using (99m) Tc and the other SPIO. (99m) Tc was injected in the morning of the day of surgery or the day before. SPIO was either injected before surgery in the outpatient clinic or 1 h before the operation.RESULTS: A total of 338 consecutive patients with breast cancer underwent 343 procedures; SPIO nanoparticles were used in 184 procedures and (99m) Tc-labelled tracer in 159. Detection rates for SPIO and (99m) Tc were 95·6 and 96·9 per cent respectively (P = 0·537). All nodes with SPIO uptake were coloured brown. Fewer nodes were retrieved with SPIO (mean 1·35 versus 1·89), regardless of whether blue dye was used (P < 0·001). Preoperative SPIO injection (58·7 per cent of procedures), a median of 16 (range 2-27) days before the procedure, was associated with a better tracer-specific detection rate (95·3 versus 86 per cent; P = 0·031) and retrieval of more nodes (mean 1·43 versus 1·03; P < 0·001) than perioperative administration. Skin staining was present in 39·9 per cent of patients, and was related to breast-conserving surgery and periareolar injection.CONCLUSION: The use of SPIO alone is a safe alternative, with results comparable to those of the standard dual technique using (99m) Tc and blue dye. The efficacy of injection in the preoperative setting simplifies logistics and improves performance. Skin staining can be prevented by a deeper peritumoral injection.
  •  
5.
  • Karakatsanis, Andreas, et al. (författare)
  • The Nordic SentiMag trial : a comparison of super paramagnetic iron oxide (SPIO) nanoparticles versus Tc(99) and patent blue in the detection of sentinel node (SN) in patients with breast cancer and a meta-analysis of earlier studies.
  • 2016
  • Ingår i: Breast Cancer Research and Treatment. - New York : Springer-Verlag New York. - 0167-6806 .- 1573-7217. ; 157:2, s. 281-294
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the study is to compare the efficacy of SPIO as a tracer in sentinel node biopsy (SNB) in breast cancer with Tc and patent blue in a multicentre prospective study and perform a meta-analysis of all published studies. It also aims to follow skin discoloration after SPIO injection and describe when and how it resolves. Totally 206 patients with early breast cancer were recruited. Tc and patent blue were administered in standard fashion. Patients were injected with SPIO (Sienna+) preoperatively. SNB was performed and detection rates were recorded for both methods. Skin discoloration was followed and documented postoperatively. Data extraction and subsequent meta-analysis of all previous studies were also performed. SN detection rates were similar between standard technique succeeded and SPIO both per patient (97.1 vs. 97.6 %, p = 0.76) as well as per node (91.3 vs. 93.3 %, p = 0.34), something which was not affected by the presence of malignancy. Concordance rates were also consistently high (98.0 % per patient and 95.9 % per node). Discoloring was present in 35.5 % of patients postoperatively, almost exclusively in breast conservation. It fades slowly and is still detectable in 8.6 % of patients after 15 months. Meta-analysis depicted similar detection rates (p = 0.71) and concordance rates (p = 0.82) per patient. However, it seems that SPIO is characterized by higher nodal retrieval (p < 0.001). SPIO is an effective method for the detection of SN in patients with breast cancer. It is comparable to the standard technique and seems to simplify logistics. Potential skin discoloration is something of consideration in patients planned for breast conservation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy