SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bergström Reinhold) ;pers:(Fritioff Tomas)"

Sökning: WFRF:(Bergström Reinhold) > Fritioff Tomas

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bergström, I, et al. (författare)
  • High-precision Mass Measurements of Hydrogen-Like 24Mg11+ and 26Mg11+ ions in a Pening Trap
  • 2002
  • Ingår i: European Physical Journal D. - : Springer Science and Business Media LLC. - 1434-6060 .- 1434-6079. ; 22:1, s. 41-45
  • Tidskriftsartikel (refereegranskat)abstract
    • For the determination of the bound-electron g factor in hydrogen-like heavy ions the mass of the ion is needed at a relative uncertainty of at least 1 ppb. With the SMILETRAP Penning trap mass spectrometer at the Manne Siegbahn Laboratory in Stockholm several mass measurements of ions with even-even nuclei at this level of precision have been performed so far, exploiting the fact that the mass precision increases linearly with the ion charge. Measurements of masses of the hydrogen-like ions of the two Mg-isotopes 24Mg and 26Mg are reported. The masses of the hydrogen-like ions are 23.979011054(14) u and 25.976562354(34) u, corresponding to the atomic masses 23.985041690(14) u and 25.982592986(34) u, respectively. The possibility to use these two isotopes for the first observation of an isotope effect in the bound-electron g factor in hydrogen-like heavy ions is discussed.
  •  
2.
  •  
3.
  • Fritioff, Tomas, et al. (författare)
  • Precise measurements of ionic masses for QED tests
  • 2006
  • Ingår i: International Journal of Mass Spectrometry. - : Elsevier BV. - 1387-3806 .- 1873-2798. ; 251:2-3, s. 281-285
  • Tidskriftsartikel (refereegranskat)abstract
    • The Penning trap mass spectrometer SMILETRAP is designed for precision mass measurements using the merits of highly charged ions. In this paper we describe the feature of SMILETRAP and give examples of mass measurements involving , , and ions. These emphasize the importance of accurate masses of hydrogen-like and lithium-like ions that are required in the evaluation of g-factor measurements of electrons bound to even–even nuclei and test of QED effects. Highly precise mass measurements can also be used for testing atomic structure calculations and determining atomic binding energies. Relevance of such measurements throughout the periodic system is discussed.
  •  
4.
  •  
5.
  • Schuch, Reinhold, et al. (författare)
  • Q value related mass determinations using a Penning trap
  • 2007
  • Ingår i: Hyperfine Interactions. - Nederländerna : Springer. - 0304-3843 .- 1572-9540. ; 173:1-3, s. 73-83
  • Tidskriftsartikel (refereegranskat)abstract
    • We report here about measurements of reaction and decay Q values by precise determination of pairs of atomic masses. These were performed with the Penning trap mass spectrometer SMILETRAP. Measurements with Penning traps give reliable and accurate masses, in particular Q values, due to the fact that certain systematic errors to a great deal cancel in the mass difference between the two atoms defining the Q value. Some Q values that are of fundamental interest will be discussed here, for example, a new Q value for the 6Li (n,γ) 7Li reaction, for the β-decay of tritium, related to properties of the electron neutrino mass, and for the neutrino-less double β-decay of 76Ge, related to the question of whether the neutrino is a Majorana particle or not. In case of the latter two we report the most accurate Q values, namely 18,589.8(12) eV for the tritium decay and 2,038.997(46) keV for the neutrino-less double β-decay of 76Ge.
  •  
6.
  • Suhonen, Markus, 1972-, et al. (författare)
  • High-frequency Ramsey excitation in a Penning trap
  • 2007
  • Ingår i: Journal of Instrumentation. - England/Italien : IOP, SISSA. - 1748-0221. ; 2:P06003, s. 1-14
  • Tidskriftsartikel (refereegranskat)abstract
    • The Ramsey excitation method for high-precision mass-measurements of highly-charged ions has been investigated and benchmarked using H2+ ions in the Penning-trap mass-spectrometer SMILETRAP. The reason for using H2+ ions are their high cyclotron frequency which is typical for the highly-charged ions usually used at SMILETRAP. Two-, three- and four-pulse Ramsey excitation data are analyzed with the help of recent theoretical work and are compared with the previously used single-pulse excitation data. An improvement factor of 2.9 in the statistical uncertainty is achieved. Furthermore the mass of 76Se, included in the previous Q-value measurement of the 76Ge neutrinoless double beta decay, is checked using 76Se25+ ions and a three-pulse Ramsey excitation. The results show a convincing agreement with the measurement when using single-pulse excitation and therefore our Q-value of 2039.006(50) keV, performed with single-pulse excitation, is confirmed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy