SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bjällmark Anna) ;hsvcat:2"

Sökning: WFRF:(Bjällmark Anna) > Teknik

  • Resultat 1-10 av 49
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Broman, Mikael, et al. (författare)
  • Recirculation during veno-venous extra-corporeal membrane oxygenation - a simulation study
  • 2015
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 38:1, s. 23-30
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical data. Methods: A closed-loop real-time simulation model of the cardiovascular system has been developed. ECMO is simulated with a fixed flow pump 0 to 5 l/min with various cannulation sites -1) right atrium to inferior vena cava, 2) inferior vena cava to right atrium, and 3) superior+ inferior vena cava to right atrium. Simulations are compared to data from a retrospective cohort of 11 consecutive adult veno-venous ECMO patients in our department. Results: Recirculation increases with increasing ECMO-flow, decreases with increasing cardiac output, and is highly dependent on choice of cannulation sites. A more peripheral drainage site decreases recirculation substantially. Conclusions: Simulations suggest that recirculation is a significant clinical problem in veno-venous ECMO in agreement with clinical data. Due to the difficulties in measuring recirculation and interpretation of the venous oxygen saturation in the ECMO drainage blood, flow settings and cannula positioning should rather be optimized with help of arterial oxygenation parameters. Simulation may be useful in quantification and understanding of recirculation in VV-ECMO.
  •  
2.
  • Mårtensson, Mattias, et al. (författare)
  • Evaluation of tissue Doppler-based velocity and deformation imaging : a phantom study of ultrasound systems.
  • 2011
  • Ingår i: European Journal of Echocardiography. - : OXFORD UNIV PRESS. - 1525-2167 .- 1532-2114. ; 12:6, s. 467-476
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The objective of this study was to test the accuracy and diagnostic interchangeability of tissue Doppler-based displacement, velocity, strain, and strain rate measurements in commercially used ultrasound (US) systems. METHODS AND RESULTS: Using an in-house made phantom, four different US scanner models were evaluated. Two different scanners of the same model were tested, and one scanner acquisition was tested twice with two generations of the same workstation giving six test results in total. The scanners were in active clinical use and are subject to regular maintenance checks. There were three displacement and four velocity results that stood out from the rest and could be regarded as accurate and interchangeable. Among the deformation measurements, three acceptable strain results were found while there were no acceptable strain rate results. Furthermore, the study showed that measurements from scanners of the same model, same acquisition post-processed on different workstations and repeated measurements from the same scanner, can yield disparate results. CONCLUSION: Measurements that are accurate and of interchangeable use can be found for displacement and velocity measurements, but are less likely to be found for strain and strain rate measurements. It is strongly recommended that the ability of each individual US scanner to measure displacement, velocity, strain, and strain rate is evaluated before it is introduced into clinical practice, and it must always be evaluated together with the workstation the scanner is intended to be used in conjunction with.
  •  
3.
  • Bjällmark, Anna, et al. (författare)
  • A system to quantify and visualize ventricular rotation pattern of the heart
  • 2009
  • Patent (populärvet., debatt m.m.)abstract
    • Different modalities have been used to describe the rotational motion of the ventricles of the heart and studies have indicated LV twist to be an additional integral component in LV function. So far, only amplitudes and timings of rotation have been reported, whereas no method is available to fully describe the rotation pattern of the ventricles. The object of the present application is to achieve a system that presents a novel way to quantify and visualize the ventricular rotation pattern of the heart. We present a novel method that assesses and describes the rotation pattern by calculating the rotation axis of the ventricle. Non- invasive image acquisition is required to collect rotation values from different positions of the myocardium. Thereafter, a kinematic model of a ventricle is constructed to determine the rotation planes at different levels of the heart. The motion of the rotation planes are visualized by plotting the normal vectors of the planes over time, i.e. the rotation axis of the planes. This new method is different to all other methods used today for assessing cardiac function, as it does not describe the amplitude of a motion but the relationship in motion between different parts within a ventricle. Preliminary results indicate that the rotation axis is more sensitive to changes in the rotation pattern than conventional measurements of ventricular rotation. This new method could be used for early detection of cardiac diseases and for selection of patients for and optimization of cardiac resynchronization therapy.
  •  
4.
  •  
5.
  • Bjällmark, Anna, et al. (författare)
  • Velocity tracking - a novel method for quantitative analysis of longitudinal myocardial function
  • 2007
  • Ingår i: Journal of the American Society of Echocardiography. - : Elsevier. - 0894-7317 .- 1097-6795. ; 20:7, s. 847-856
  • Tidskriftsartikel (refereegranskat)abstract
    • Doppler tissue imaging is a method for quantitative analysis of longitudinal myocardial velocity. Commercially available ultrasound systems can only present velocity information using a color Dopplerbased overlapping continuous color scale. The analysis is time-consuming and does not allow for simultaneous analysis in different projections. We have developed a new method, velocity tracking, using a stepwise color coding of the regional longitudinal myocardial velocity. The velocity data from 3 apical projections are presented as static and dynamic bull's-eye plots to give a 3-dimensional understanding of the function of the left ventricle. The static bull's-eye plot can display peak systolic velocity, late diastofic tissue velocity, or the sum of peak systolic velocity and early diastolic tissue velocity. Conversely, the dynamic bull's-eye plot displays how the myocardial velocities change over one heart cycle. Velocity tracking allows for a fast, simple, and hituitive visual analysis of the regional longitudinal contraction pattern of the left ventricle with a great potential to identify characteristic pathologic patterns.
  •  
6.
  • Brodin, Lars-Åke, et al. (författare)
  • Global and local detection of blood vessel elasticity
  • 2006
  • Patent (populärvet., debatt m.m.)abstract
    • The present invention is a non-invasive analysis system for detection of global and local blood vessel elasticity. The analysis system comprises two subsystems where subsystem 1 is data collecting unit and subsystem 2 is an analysis unit. The data collecting unit comprises one or many non-invasive image generating systems, or the data collecting system makes the registration possible of movement parameters that quantifies the dynamics of the blood vessel wall in longitudinal and radial directions. Subsystem 2 performs Wave Intensity Analysis which is an analysis method using co-related parts of the circulation system by measuring the intensity change (dl) of the blood vessel during a heart cycle. The intensity change is calculated as the product of the pressure derivate and the flow velocity derivate. In subsystem 2 the changes of pressure and flow are approximated by the deformation velocity or velocity of the radial and longitudinal direction, respectively. By calculating time constants and amplitudes of the intensity change graph a measure is obtained of the local and global elasticity of the blood vessel and atherosclerotic constrictions of arterial vessels may then be identified at an early stage.
  •  
7.
  •  
8.
  • Härmark, Johan, et al. (författare)
  • Investigation of the elimination process of a multimodal polymer-shelled contrast agent in rats using ultrasound and transmission electron microscopy
  • 2015
  • Ingår i: Biomedical Spectroscopy and Imaging. - 2212-8794. ; 4:1, s. 81-93
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: A novel polymer-shelled contrast agent (CA) with multimodal imaging and target specific potential was developed recently and tested for its acoustical properties using different in-vitro setups.OBJECTIVE: The aim of this study was to investigate the elimination of three types of the novel polymer-shelled CA, one unmodified and two shell modified versions, in rats.METHODS: The blood elimination time was estimated by measuring the image intensity, from ultrasound images of the common carotid artery, over time after a bolus injection of the three types of the novel CA. The commercially available CA SonoVue was used as a reference. The subcellular localization of the three CAs was investigated using transmission electron microscopy.RESULTS: The ultrasound measurements indicated a blood half-life of 17–85 s for the different types of the novel CA, which was significant longer than the blood half-life time for SonoVue. Additionally, CAs were exclusively found in the circulatory system, either taken up by, or found in the vicinity of macrophages.CONCLUSIONS: Compared to the commercially available CA SonoVue, the blood circulation times for the three types of the novel polymer-shelled CA were prolonged. Moreover, macrophages were suggested to be responsible for the elimination of the CA.
  •  
9.
  •  
10.
  • Larsson, Matilda, et al. (författare)
  • In-vivo assessment of radial and longitudinal strain in the carotid artery using speckle tracking
  • 2010
  • Ingår i: 2010 IEEE International Ultrasonics Symposium Proceedings. - : IEEE. - 9781457703829 ; , s. 1328-1331
  • Konferensbidrag (refereegranskat)abstract
    • Ultrasound-based algorithms are commonly used to assess mechanical properties of arterial walls in studies of arterial stiffness and atherosclerosis. Speckle tracking based techniques used for estimation of myocardial strain can be applied on vessels to estimate strain of the arterial wall. Previous elastography studies in vessels have mainly focused on radial strain measurements, whereas the longitudinal strain has been more or less ignored. However, recently we showed the feasibility of speckle tracking to assess longitudinal strain of the carotid artery in-silico. The aim of this study was to test this methodology in-vivo. Ultrasound images were obtained in seven healthy subjects with no known cardiovascular disease (39 ± 14 years old) and in seven patients with coronary artery disease (CAD), (69 ± 4 years old). Speckle tracking was performed on the envelope detected data using our previous developed algorithm. Radial and longitudinal strains were estimated throughout two cardiac cycles in a region of interest (ROI) positioned in the posterior vessel wall. The mean peak systolic radial and longitudinal strain values from the two heart cycles were compared between the groups using a student's t-test. The mean peak radial strain was -39.1 ± 15.1% for the healthy group and -20.4 ± 7.5% for the diseased group (p = 0.01), whereas the mean peak longitudinal strain was 4.8 ± 1.1% and 3.2 ± 1.6% (p = 0.05) for the healthy and diseased group, respectively. Both peak radial and longitudinal strain values were thus significantly reduced in the CAD patient group. This study shows the feasibility to estimate radial and longitudinal strain in-vivo using speckle tracking and indicates that the method can detect differences between groups of healthy and diseased (CAD) subjects.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 49
Typ av publikation
konferensbidrag (26)
tidskriftsartikel (18)
doktorsavhandling (2)
patent (2)
annan publikation (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (24)
refereegranskat (23)
populärvet., debatt m.m. (2)
Författare/redaktör
Bjällmark, Anna (48)
Larsson, M (19)
Larsson, Matilda (17)
Brodin, Lars-Åke (13)
Lind, B (8)
Caidahl, Kenneth (8)
visa fler...
Nowak, J. (4)
Lindholm, B (4)
Kremer, F. (4)
Gustafsson, U (3)
Paradossi, Gaio (3)
Larsson, David (3)
Waldenstrom, A. (2)
Brodin, L A (2)
Janerot-Sjöberg, Bir ... (2)
Caidahl, K (2)
Falkmer, Marita, 195 ... (2)
Falkmer, Torbjörn, 1 ... (2)
Brodin, L (2)
Peolsson, Michael (2)
Jacobsen, P (2)
Larsson, Malin K. (2)
Nordenfur, Tim, 1990 ... (2)
Larsson, D (2)
Lindqvist, P. (2)
Nowak, Greg (1)
Haney, M. (1)
Johnson, J (1)
Urban, M (1)
Engvall, Jan (1)
Manouras, A (1)
Falkmer, Torbjörn (1)
Dukic, Tania (1)
Brismar, Torkel (1)
Szummer, Karolina (1)
Brismar, TB (1)
Dhooge, Jan (1)
Hebert, Hans (1)
Waldenström, A (1)
Nygren, M. (1)
Brodin, Lars-Åke, Pr ... (1)
Ugander, Martin (1)
Larsson, Malin (1)
Balzano, R (1)
Lundbäck, Stig (1)
Seeberger, Astrid (1)
Paradossi, G (1)
Bassan, Gioia (1)
Frenckner, Bjorn (1)
Lundback, S. (1)
visa färre...
Lärosäte
Jönköping University (46)
Kungliga Tekniska Högskolan (26)
Karolinska Institutet (10)
Uppsala universitet (1)
Linköpings universitet (1)
Språk
Engelska (49)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
Naturvetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy