SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Björck Martin) ;pers:(Nyman Rickard)"

Sökning: WFRF:(Björck Martin) > Nyman Rickard

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bergqvist, David, et al. (författare)
  • Secondary aortoenteric fistula after endovascular aortic interventions : a systematic literature review
  • 2008
  • Ingår i: Journal of Vascular and Interventional Radiology. - : Elsevier BV. - 1051-0443 .- 1535-7732. ; 19:2, s. 163-165
  • Forskningsöversikt (refereegranskat)abstract
    • PURPOSE: To evaluate the collective incidence of, and experience with, aortoenteric fistula after endovascular aortoiliac therapy. MATERIALS AND METHODS: A systematic literature research was performed to identify cases of aortoenteric fistulation after aortic stent-graft procedures or stent implantation. RESULTS: The review revealed 16 cases of aortoenteric fistulation after aortic stent-grafting (n = 15) or stent placement (n = 1), in 14 patients with abdominal aortic aneurysm. Six had undergone endovascular aneurysm repair because of what was considered a "hostile abdomen." The symptoms did not differ from those in patients with arterioenteric fistulation after open aortic repair. A defect in the stent-graft or its function was the predominant cause of fistulation. One fistula was diagnosed at autopsy, two patients died perioperatively, and 13 survived with in situ repair or an axillobifemoral graft, all after removal of the stent-graft or stent. However, the follow-up time was short, longer than 1 year in only five of the 13 survivors. CONCLUSIONS: Aortoenteric fistulation does occur after endovascular implantation of stents and stent-grafts. The incidence is unknown but is probably low. Follow-up time in most publications was less than 1 year, which is considered short to assess potential graft infection.
  •  
2.
  • Bergqvist, David, et al. (författare)
  • Svårkontrollerad blödning vid kirurgi - praktiska åtgärder
  • 2007
  • Ingår i: Läkartidningen. - 0023-7205 .- 1652-7518. ; 104:6, s. 407-411
  • Tidskriftsartikel (refereegranskat)abstract
    • Difficult-to-control intraoperative bleeding--practical measures Bleeding with difficulties obtaining haemostasis can be a catastrophe. This paper summarizes a symposium with the above title. A short introduction gives the background of normal haemostasis as well as iatrogenic vascular injuries as reflected in the Swedish vascular registry (Swedvasc). Practical guidelines are given on how to manage situations of severe haemorrhage with the help of pharmacological substances, local haemostatics, endovascular methodology and open surgery.
  •  
3.
  •  
4.
  •  
5.
  • Lindberg, Fredrik, et al. (författare)
  • Low frequency of phlebographic deep vein thrombosis after laparoscopic cholecystectomy : a pilot study
  • 2006
  • Ingår i: Clinical and applied thrombosis/hemostasis. - : SAGE Publications. - 1076-0296 .- 1938-2723. ; 12:4, s. 421-426
  • Tidskriftsartikel (refereegranskat)abstract
    • To investigate the rate of deep vein thrombosis (DVT) after laparoscopic surgery, 50 patients underwent bilateral phlebography 7-11 days after laparoscopic cholecystectomy (LC). All received thromboembolism prophylaxis, either low molecular weight heparin (LMWH) or dextran. Three patients were converted to open cholecystectomy. D-dimer was investigated preoperatively, on day 1 and on the day of phlebography. One asymptomatic DVT was found. One phlebogram was incomplete. Seven phlebograms were not optimal but of sufficient quality to rule out DVT. The frequency of DVT was thus 1 of 49 or 2.0% (95% confidence interval, 0-6.0%). No anticoagulants were prescribed after discharge. No patient developed late thromboembolic complications. D-dimer values increased significantly at day 1 and were further increased at the time of phlebography. The frequency of phlebographical DVTs thus seems to be low despite prophylaxis of questionable efficacy. The D-dimer values, however, suggest that the effects of LC on coagulation/fibrinolysis have a duration of longer than 1 week.
  •  
6.
  • Skagius, Elisabet, et al. (författare)
  • Percutaneous Closure of Large Femoral Artery Access with Prostar XL in Thoracic Endovascular Aortic Repair
  • 2013
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 46:5, s. 558-563
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES:To investigate the technical success rate of Prostar XL for closure of large (≥20F) femoral vascular access sites in thoracic endovascular aortic repair (TEVAR) procedures.METHODS:This was a single-center consecutive case series. All TEVAR procedures at Uppsala University Hospital 2006-2010 were registered prospectively. Reoperations and cases with open closure technique were excluded. Primary (early) technical failure was defined as closure failure requiring immediate (on-table) open surgical repair; late access-related complication occurred thereafter. The medical records, pre- and postoperative computed tomography images were reviewed retrospectively.RESULTS:A total of 164 TEVAR procedures were identified, of which 118 (71%) had a median 22F (range 20-26F) access site sealed with tandem Prostar XL. The indications for TEVAR were dissection (47%), aneurysm (42%), trauma (8%), and miscellaneous (3%). Median follow-up time was 10 months (range 1-62). Primary technical failure occurred in 10 of 118 (8%). These cases were converted to cut-downs and surgical repair (n = 7), femoral fascia suturing (n = 2), and external compression with the Femo-Stop device (n = 1). Hypertension was associated with primary failure (p = .005), and a trend was observed for high age (p = .078) and increased groin subcutaneous fat layer (p = .077). Late access-related complications included pseudo-aneurysms (n = 12), small hematomas (n = 7), superficial groin infections (n = 2), and deep venous thrombosis (n = 1). None of the late complications required surgical treatment.CONCLUSIONS:The access closure technique with tandem Prostar XL for large access sites during TEVAR is safe, in experienced hands. Few technical failures and few late complications occur, and they are usually benign.
  •  
7.
  • Steuer, Johnny, et al. (författare)
  • Early and Long-term Outcome after Thoracic Endovascular Aortic Repair (TEVAR) for Acute Complicated Type B Aortic Dissection
  • 2011
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 41:3, s. 318-323
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The study aimed to investigate early and long-term outcome of thoracic endovascular aortic repair (TEVAR) for acute complicated type B dissection. DESIGN: This was a retrospective, single-centre, consecutive case series. MATERIALS AND METHODS: During the period 1999-2009, TEVAR was carried out in 50 patients with non-traumatic acute complicated type B dissection, and in another 10 patients with acute complications, including rupture, end-organ ischaemia and acute dilatation during the primary hospitalisation, but >14 days after onset of symptoms. Thus, in total, 60 patients were included; 22 with a DeBakey type IIIa dissection and 38 with a type IIIb; median age was 67 years. Early (30-day) and long-term (5-year) survival, re-intervention rate and complications were recorded until 1 July 2010. RESULTS: Within 30 days, two (3%) deaths, one (2%) paraplegia and three (5%) strokes were observed. Five-year survival was 87% and freedom from re-intervention at 5 years was 65%. CONCLUSIONS: In patients with acute complicated type B aortic dissection, TEVAR can be performed with excellent early and long-term survival, whereas morbidity and long-term durability must be further elucidated.
  •  
8.
  • Steuer, Johnny, et al. (författare)
  • Outcome of endovascular treatment of traumatic aortic transection
  • 2012
  • Ingår i: Journal of Vascular Surgery. - : Elsevier BV. - 0741-5214 .- 1097-6809. ; 56:4, s. 973-978
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE:The purpose of this study was to analyze our experience of thoracic endovascular aortic repair (TEVAR) in patients with traumatic aortic transection.METHODS:This was a single-center consecutive case series that was conducted at the Uppsala University Hospital, Tertiary Referral Center. There were a total of 17 consecutive patients undergoing TEVAR for traumatic thoracic aortic transection. All patients undergoing TEVAR for aortic transection were registered prospectively and their medical records were reviewed regarding technical details, mechanism of injury, and concomitant injuries. Long-term outcome was analyzed with respect to need for reintervention and survival.RESULTS: Between 2001 and 2010, 17 patients underwent TEVAR for traumatic aortic injury. Median age was 42 years (range, 18-77 years), and 15 of 17 patients (88%) were men. Fourteen patients had been involved in motor vehicle accidents, two had fallen from heights, and one fell off a bicycle on a slope. In all cases, the aortic injury was located in the proximity of the origin of the left subclavian artery. All patients had concomitant injuries. In all patients, a single stent graft was sufficient to exclude the injured part of the aorta. The median cover length was 120 mm (range, 100-200 mm). In-hospital mortality was 24% (4 of 17 patients). One patient died perioperatively and three postoperatively, two from brain injuries and one from multiorgan failure. After a median follow-up of 36 months (range, 10-98 months), three patients underwent reintervention (18%), each patient only once; one for a type-I endoleak, and two for pseudocoarctation secondary to stent graft infolding. Two were treated endovascularly, and one had a stent graft explantation.CONCLUSIONS: Endovascular repair allows rapid and minimally invasive therapy in patients with traumatic aortic injury with good technical results. The outcome is highly dependent on the severity of other concurrent injuries.
  •  
9.
  • Sörelius, Karl, et al. (författare)
  • Endovascular repair of mycotic aortic aneurysms
  • 2009
  • Ingår i: Journal of vascular surgery. - : Elsevier BV. - 0741-5214. ; 50:2, s. 269-274
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: We report our single-center experience of early and midterm outcome after endovascular repair of mycotic aortic aneurysms (MAA). METHODS: Case records were retrospectively reviewed of 11 patients who underwent endovascular repair of 13 MAAs between 2000 and 2007. The aneurysms were localized in the aortic arch in 1 patient, descending thoracic aorta in 4, suprarenal abdominal aorta in 3, and infrarenal abdominal aorta in 5. RESULTS: Mean follow-up was 27 months. A bleeding aortoesophageal fistula resulted in one in-hospital death
  •  
10.
  • Wanhainen, Anders, et al. (författare)
  • First report of a late type III endoleak from fabric tears of a Zenith stent graft
  • 2008
  • Ingår i: Journal of vascular surgery. - : Elsevier BV. - 0741-5214. ; 48:3, s. 723-726
  • Tidskriftsartikel (refereegranskat)abstract
    • We report a case of a late type III endoleak from a hole in the fabric of the main body of a Zenith bifurcated endograft 7 years after implantation. Abdominal pain and a rapidly expanding aneurysm were eventually followed by rupture. The defect was detected at open surgery, whereas no evidence of endoleak was found at preoperative computed tomography (CT) or angiogram. The defect was repaired by a relining procedure with an Excluder stent graft. The patient, however, died 3 weeks after admission.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy