SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bjursten Lars Magnus) ;lar1:(gu)"

Sökning: WFRF:(Bjursten Lars Magnus) > Göteborgs universitet

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bjursten, Lars Magnus, et al. (författare)
  • Titanium dioxide nanotubes enhance bone bonding in vivo.
  • 2010
  • Ingår i: Journal of biomedical materials research. Part A. - : Wiley. - 1552-4965 .- 1549-3296. ; 92:3, s. 1218-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Implant topography is critical to the clinical success of bone-anchored implants, yet little is known how nano-modified implant topography affects osseointegration. We investigate the in vivo bone bonding of two titanium implant surfaces: titanium dioxide (TiO(2)) nanotubes and TiO(2) gritblasted surfaces. In previous in vitro studies, the topography of the TiO(2) nanotubes improved osteoblast proliferation and adhesion compared with gritblasted titanium surfaces. After four weeks of implantation in rabbit tibias, pull-out testing indicated that TiO(2) nanotubes significantly improved bone bonding strength by as much as nine-fold compared with TiO(2) gritblasted surfaces. Histological analysis confirmed greater bone-implant contact area, new bone formation, and calcium and phosphorus levels on the nanotube surfaces. It is anticipated that further studies will contribute to a better understanding of the effect of implant nanotopography on in vivo bone formation and bonding strength.
  •  
2.
  • Bjursten, Henrik, et al. (författare)
  • Infective endocarditis after transcatheter aortic valve implantation: a nationwide study
  • 2019
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 40:39, s. 3263-3269
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims  Transcatheter aortic valve implantation (TAVI), now a common procedure to treat high-risk patients with severe aortic stenosis, has rapidly been expanding into younger and lower-risk populations, creating a need to better understand long-term outcome after TAVI. The aim of the present investigation was to determine the incidence, risk factors for, clinical presentation of, and outcome after prosthetic valve endocarditis (PVE) in patients treated with TAVI in a nationwide study. Methods and results  Three registries were used: a national TAVI registry, a national diagnosis registry, and a national infective endocarditis registry. Combining these registries made it possible to perform a nationwide, all-comers study with independent and validated reporting of PVE in 4336 patients between 2008 and mid-2018. The risk for PVE after TAVI was 1.4% (95% confidence interval 1.0–1.8%) the first year and 0.8% (0.6–1.1%) per year thereafter. One-year survival after PVE diagnosis was 58% (49–68%), and 5-year survival was 29% (17–41%). Body surface area, estimated glomerular filtration rate <30 mL/min/1.73 m2, critical pre-operative state, mean pre-procedural valve gradient, amount of contrast dye used, transapical access, and atrial fibrillation were identified as independent risk factors for PVE. Staphylococcus aureus was more common in early (<1 year) PVE. Infection with S. aureus, root abscess, late PVE, and non-community acquisition was associated with higher 6-month mortality. Conclusion  The incidence of PVE was similar to that of surgical bioprostheses. Compromised renal function was a strong risk factor for developing PVE. In the context of PVE, TAVI seems to be a safe option for patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy