SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bocchi A) "

Sökning: WFRF:(Bocchi A)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jentschel, M., et al. (författare)
  • EXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility
  • 2017
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of gamma-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) ns(-1)cm(2) at the target position and negligible neutron halo. The targetwas surrounded by an array of eight to ten anti-Compton shielded EXOGAMClover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectorswere arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 x 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico-to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of Ba-133, Co-60 and Eu-152 as well as data from the reactions Al-27(n, gamma)Al-28 and Cl-35(n,gamma)Cl-36 in the energy range from 30 keV up to 10MeV.
  •  
2.
  • Ralet, D., et al. (författare)
  • Evidence of octupole-phonons at high spin in Pb-207
  • 2019
  • Ingår i: Physics Letters B. - : ELSEVIER. - 0370-2693 .- 1873-2445. ; 797
  • Tidskriftsartikel (refereegranskat)abstract
    • A lifetime measurement of the 19/2(-) state in Pb-207 has been performed using the Recoil Distance Doppler-Shift (RDDS) method. The nuclei of interest were produced in multi-nucleon transfer reactions induced by a Pb-208 beam impinging on a Mo-100 enriched target. The beam-like nuclei were detected and identified in terms of their atomic mass number in the VAMOS++ spectrometer while the prompt gamma rays were detected by the AGATA tracking array. The measured large reduced transition probability B(E3, 19/2(-) -> 13/2(+)) = 40(8) W.u. is the first indication of the octupole phonon at high spin in Pb-207. An analysis in terms of a particle-octupole-vibration coupling model indicates that the measured B(E3) value in Pb-207 is compatible with the contributions from single-phonon and single particle E3 as well as E3 strength arising from the double-octupole-phonon 6(+) state, all adding coherently. A crucial aspect of the coupling model, namely the strong mixing between single-hole and the phonon-hole states, is confirmed in a realistic shell-model calculation. Crown Copyright (C) 2019 Published by Elsevier B.V.
  •  
3.
  • Ceruti, S., et al. (författare)
  • Isospin Mixing in Zr-80 : From Finite to Zero Temperature
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 115:22
  • Tidskriftsartikel (refereegranskat)abstract
    • The isospin mixing was deduced in the compound nucleus Zr-80 at an excitation energy of E* = 54 MeV from the gamma decay of the giant dipole resonance. The reaction Ca-40 + Ca-40 at E-beam = 136 MeV was used to form the compound nucleus in the isospin I = 0 channel, while the reaction Cl-37 + Ca-44 at E-beam = 95 MeV was used as the reference reaction. The. rays were detected with the AGATA demonstrator array coupled with LaBr3:Ce detectors. The temperature dependence of the isospin mixing was obtained and the zero-temperature value deduced. The isospin-symmetry-breaking correction delta(C) used for the Fermi superallowed transitions was extracted and found to be consistent with beta-decay data.
  •  
4.
  • Jung, Christian, et al. (författare)
  • A comparison of very old patients admitted to intensive care unit after acute versus elective surgery or intervention
  • 2019
  • Ingår i: Journal of critical care. - : W B SAUNDERS CO-ELSEVIER INC. - 0883-9441 .- 1557-8615. ; 52, s. 141-148
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: We aimed to evaluate differences in outcome between patients admitted to intensive care unit (ICU) after elective versus acute surgery in a multinational cohort of very old patients (80 years; VIP). Predictors of mortality, with special emphasis on frailty, were assessed.Methods: In total, 5063 VIPs were induded in this analysis, 922 were admitted after elective surgery or intervention, 4141 acutely, with 402 after acute surgery. Differences were calculated using Mann-Whitney-U test and Wilcoxon test. Univariate and multivariable logistic regression were used to assess associations with mortality.Results: Compared patients admitted after acute surgery, patients admitted after elective surgery suffered less often from frailty as defined as CFS (28% vs 46%; p < 0.001), evidenced lower SOFA scores (4 +/- 5 vs 7 +/- 7; p < 0.001). Presence of frailty (CFS >4) was associated with significantly increased mortality both in elective surgery patients (7% vs 12%; p = 0.01), in acute surgery (7% vs 12%; p = 0.02).Conclusions: VIPs admitted to ICU after elective surgery evidenced favorable outcome over patients after acute surgery even after correction for relevant confounders. Frailty might be used to guide clinicians in risk stratification in both patients admitted after elective and acute surgery. 
  •  
5.
  •  
6.
  • Ballerini, L., et al. (författare)
  • Determination of Pores in Pig Meat Images
  • 2002
  • Ingår i: International Conference on Computer Vision and Graphics, Zakopane, Poland. ; , s. 70-78, s. 53-56
  • Konferensbidrag (refereegranskat)abstract
    • In this paper we present an image processing application for
  •  
7.
  • Bocchi, E. A., et al. (författare)
  • Effect of Combining Ivabradine and beta-Blockers: Focus on the Use of Carvedilol in the SHIFT Population
  • 2015
  • Ingår i: Cardiology. - : S. Karger AG. - 0008-6312 .- 1421-9751. ; 131:4, s. 218-224
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: We explored the prescription of beta-blockers with ivabradine in patients with systolic heart failure, focusing on the most frequently coprescribed beta-blocker, carvedilol. Methods: We analyzed outcomes in SHIFT patients with systolic heart failure who were prescribed beta-blockers (carvedilol, bisoprolol, metoprolol, or nebivolol) with ivabradine or placebo. Analysis was by intention to treat in patients prescribed a beta-blocker at the time of the event. Results: Data were available for 2,596 patients receiving carvedilol, 1,483 bisoprolol, 1,424 metoprolol, and 197 nebivolol. Mean treatment duration was 19 months. There was no difference in the effect of ivabradine on the primary composite endpoint of cardiovascular death or heart failure hospitalization between the various beta-blockers [hazard ratios (HR) for risk reduction, 0.75-0.89; p for interaction = 0.86]. Patients prescribed carvedilol with ivabradine had lower rates of primary composite endpoint (HR 0.80, 95% CI: 0.68-0.94), heart failure hospitalization (HR 0.73, 95% CI: 0.61-0.88), and cardiovascular hospitalization (HR 0.80, 95% CI: 0.69-0.92) versus carvedilol with placebo. The dosage of carvedilol had no detectable effect and there were no unexpected safety issues. Conclusions: Whatever beta-blocker was coprescribed with ivabradine, there were improvements in cardiovascular outcomes in patients with systolic heart failure, especially with the most prescribed beta-blocker - carvedilol. (C) 2015 S. Karger AG, Basel
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy