  • Cros, Olivier, et al. (författare)
  • Determination of the mastoid surface area and volume based on micro-CT scanning of human temporal bone : Geometrical parameters dependence on scanning resolutions
  • 2016
  • Ingår i: Hearing Research. - : Elsevier BV. - 0378-5955 .- 1878-5891. ; 340, s. 127-134
  • Tidskriftsartikel (refereegranskat)abstract
    • The mastoid air cell system (MACS) with its large complex of interconnected air cells reflects an enhanced surface area (SA) relative to its volume (V), which may indicate that the MACS is adapted to gas exchange and has a potential role in middle ear pressure regulation. Thus, these geometric parameters of the MACS have been studied by high resolution clinical CT scanning. However, the resolution of these scans is limited to a voxel size of around 0.6 mm in all dimensions, and so, the geometrical parameters are also limited. Small air cells may appear below the resolution and cannot be detected. Such air cells may contribute to a much higher SA than the V, and thus, also the SA/V ratio. More accurate parameters are important for analysis of the function of the MACS including physiological modeling.Our aim was to determine the SA, V, and SA/V ratio in MACS in human temporal bones at highest resolution by using micro-CT-scanning. Further, the influence of the resolution on these parameters was investigated by downsampling the data. Eight normally aerated temporal bones were scanned at the highest possible resolution (30-60 μm). The SA was determined using a triangular mesh fitted onto the segmented MACS. The V was determined by summing all the voxels containing air. Downsampling of the original data was applied four times by a factor of 2.The mean SA was 194 cm2, the mean V was 9 cm3, and the mean SA/V amounted to 22 cm-1. Decreasing the resolution resulted in a non-linear decrement of SA and SA/V, whereas V was mainly independent of the resolution.The current study found significantly higher SA and SA/V compared with previous studies using clinical CT scanning at lower resolutions. These findings indicate a separate role of the MACS compared with the tympanum, and the results are important for a more accurate modeling of the middle ear physiology.
  •  
3.
  • Knutsson, Hans, 1950-, et al. (författare)
  • Automated generation of representations in vision
  • 2000
  • Ingår i: International Conference on Pattern Recognition ICPR,2000. - Barcelona, Spain : IEEE. - 0769507506 ; , s. 59-66 vol.3
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a general strategy for automated generation of efficient representations in vision. The approach is highly task oriented and what constitutes the relevant information is defined by a set of examples. The examples are pairs of situations that are dependent through the chosen feature but are otherwise independent. Particularly important concepts in the work are mutual information and canonical correlation. How visual operators and representations can be generated from examples are presented for a number of features, e.g. local orientation, disparity and motion. Interesting similarities to biological vision functions are observed. The results clearly demonstrates the potential of combining advanced filtering techniques and learning strategies based on canonical correlation analysis (CCA).
  •  
4.
  • Knutsson, Hans, 1950-, et al. (författare)
  • Motion artifact reduction in MRI through generalized DFT
  • 2004
  • Ingår i: Biomedical Imaging: Nano to Macro, 2004. IEEE International Symposium on. - : IEEE. - 0780383885 ; , s. 896-899 vol.1
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a method that dramatically reduces artifacts caused by respiratory (and similar types of) patient motion in magnetic resonance imaging (MRI). The basis for the method is the observation that affine deformations of an object will correspond to a different but unique affine coordinate transform (plus phase shift) of the Fourier representation of the object. The resulting sample points will be irregularly distributed prohibiting the use of standard IFFT to reconstruct the object. The object can however be reconstructed through the use of a weighted regularized pseudo inverse. A standard pseudo inverse is, however, not possible due to excessive computational demands. For this reason a novel fast sequential pseudo inverse algorithm is also presented. Significantly improved results are obtained on both synthetic and clinical data.
  •  
5.
  • Knutsson, Hans, et al. (författare)
  • Respiratory Arifact Reduction in MRI using Dynamic Deformation Modelling
  • 2002
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • This paper presents a novel magnetic resonance imaging (MRI) reconstruction method that will reconstruct an object correctly despite the presence of respiratory-type motions. The basis for the method is the observation that affine deformations of an object will correspond to a different but unique affine coordinate transform of the Fourier representation (k-space) of the object. The resulting sample points will be irregularly distributed prohibiting the use of standard IFFT to reconstruct the object. The object can however be reconstructed through the use of a weighted regularized pseudo inverse. Short computing times are obtained using a novel fast sequential pseudo inverse algorithm. 
  •  