1.
  • Brockstedt, Sara, et al. (författare)
  • Quantitative diffusion coefficient maps using fast spin-echo MRI
  • 1998
  • Ingår i: Magnetic Resonance Imaging. - 1873-5894. ; 16:8, s. 877-886
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence. The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes. Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients. The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written. Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28-50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo.
  •  
2.
  • Brockstedt, Sara, et al. (författare)
  • Triggering in quantitative diffusion imaging with single-shot EPI
  • 1999
  • Ingår i: Acta Radiologica. - 1600-0455. ; 40:3, s. 263-269
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion. MATERIAL AND METHODS: Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all. RESULTS: The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering. CONCLUSION: The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.
  •  
3.
  • Brockstedt, Sara, et al. (författare)
  • Use of an enhanced gradient system for diffusion MR imaging with motion-artifact reduction
  • 1995
  • Ingår i: Acta Radiologica. - 1600-0455. ; 36:6, s. 662-670
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: A spin-echo diffusion-sensitized pulse sequence using high gradients (23 mT/m) is introduced. MATERIAL AND METHODS: In order to minimize motion artefacts, velocity-compensating gradients, ECG-triggering and post-processing with phase correction and raw data averaging using navigator echoes was performed. The in vitro ratio of diffusion coefficients for water and acetone was determined and the water self-diffusion coefficient at different temperatures was evaluated. The pulse sequence was tested in 7 healthy volunteers and in 2 tumour patients with astrocytomas of grades I-II and III-IV. Both single-slice and multi-slice techniques were used. RESULTS: The incorporation of phase correction clearly improved the quality of both diffusion-encoded images and the calculated diffusion maps. Mean values of the diffusion coefficients in vivo were for CSF 2.66 x 10(-9) m2/s and for white and grey matter 0.69 x 10(-9) m2/s and 0.87 x 10(-9) m2/s, respectively. CONCLUSION: Velocity-compensating gradients in combination with a high gradient strength were shown to be useful for in vivo diffusion MR imaging.
  •  
4.
  • Lätt, Jimmy, et al. (författare)
  • Accuracy of q-space related parameters in MRI: Simulations and phantom measurements
  • 2007
  • Ingår i: IEEE Transactions on Medical Imaging. - 1558-254X. ; 26:11, s. 1437-1447
  • Tidskriftsartikel (refereegranskat)abstract
    • The accuracy of q-space measurements was evaluated at a 3.0-T clinical magnetic resonance imaging (MRI) scanner, as compared with a 4.7-T nuclear magnetic resonance (NMR) spectrometer. Measurements were performed using a stimulated-echo pulse-sequence on n-decane as well as on polyethylene glycol (PEG) mixed with different concentrations of water, in order to obtain bi-exponential signal decay curves. The diffusion coefficients as well as the modelled diffusional kurtosis K-fit, were obtained from the signal decay curve, while the full-width at half-maximum (FWHM) and the diffusional kurtosis K were obtained from the displacement distribution. Simulations of restricted diffusion, under conditions similar to those obtainable with a clinical MRI scanner, were carried out assuming various degrees of violation of the short gradient pulse (SGP) condition and of the long diffusion time limit., The results indicated that an MRI system can not be used for quantification of structural sizes less than about 10 mu m by means of FWHM since the parameter underestimates the confinements due to violation of the SGP condition. However, FWHM can still be used as an important contrast parameter. The obtained kurtosis values were lower than expected from theory and the results showed that care must be taken when interpreting a kurtosis estimate deviating from zero.
  •  
5.
  • Lätt, Jimmy, et al. (författare)
  • Diffusion-weighted MRI measurements on stroke patients reveal water-exchange mechanisms in sub-acute ischaemic lesions.
  • 2009
  • Ingår i: NMR in Biomedicine. - : Wiley. - 0952-3480 .- 1099-1492. ; 22:6, s. 619-628
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate the diffusion time dependence of signal-versus-b curves obtained from diffusion-weighted magnetic resonance imaging (DW-MRI) of sub-acute ischaemic lesions in stroke patients. In this case series study, 16 patients with sub-acute ischaemic stroke were examined with DW-MRI using two different diffusion times (60 and 260 ms). Nine of these patients showed sufficiently large lesions without artefacts to merit further analysis. The signal-versus-b curves from the lesions were plotted and analysed using a two-compartment model including compartmental exchange. To validate the model and to aid the interpretation of the estimated model parameters, Monte Carlo simulations were performed. In eight cases, the plotted signal-versus-b curves, obtained from the lesions, showed a signal-curve split-up when data for the two diffusion times were compared, revealing effects of compartmental water exchange. For one of the patients, parametric maps were generated based on the extracted model parameters. These novel observations suggest that water exchange between different water pools is measurable and thus potentially useful for clinical assessment. The information can improve the understanding of the relationship between the DW-MRI signal intensity and the microstructural properties of the lesions. Copyright (c) 2009 John Wiley & Sons, Ltd.
  •  
6.
  • Lätt, Jimmy, et al. (författare)
  • Effects of restricted diffusion in a biological phantom: a q-space diffusion MRI study of asparagus stems at a 3T clinical scanner
  • 2007
  • Ingår i: Magma. - : Springer Science and Business Media LLC. - 1352-8661. ; 20:4, s. 213-222
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction The aim of this work was to study the effects of restricted diffusion in a biological phantom consisting of green asparagus stems using q-space MRI at a clinical scanner. Method Measurements of the full width at half maximum (FWHM) of the displacement distribution were performed with varied diffusion time (T d). The accuracy of the measurements was investigated with respect to the degree of violation of the short gradient pulse (SGP) condition, partial volume effects and a FWHM-based tensor model. Results The measurements showed a reasonably constant FWHM perpendicular to the capillaries in the vascular bundles and an increased FWHM parallel with the bundles when the T d was increased. A 15% decrease in FWHM perpendicular to the bundles was observed when the diffusion encoding duration was prolonged from 24 to 74 ms, owing to the violation of the SGP condition. For a population of different confinement sizes, simulations indicated that the FWHM reflects the smaller sizes rather then the mean size of the confinements. Conclusion A new method allowing tensor analysis of FWHM was derived and yielded accurate results. In conclusion, we found it possible to measure the effects of restricted diffusion with q-space MRI using a clinical MRI scanner.
  •  
7.
  • Lätt, Jimmy, et al. (författare)
  • In vivo visualization of displacement-distribution-derived parameters in q-space imaging.
  • 2008
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 1873-5894 .- 0730-725X. ; 26:1, s. 77-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective This study aimed to explore the potential of in vivo q-space imaging in the differentiation between different cerebral water components. Materials and Methods Diffusion-weighted imaging was performed in six directions with 32 equally spaced q values and a maximum b value of 6600 s/mm2. The shape of the signal-attenuation curve and the displacement propagator were examined and compared with a normal distribution using the kurtosis parameter. Maps displaying kurtosis, fast and slow components of the apparent diffusion coefficients, fractional anisotropy and directional diffusion were calculated. The displacement propagator was further described by the full width at half and at tenth maximum and by the probability density of zero displacement P(0). Three healthy volunteers and three patients with previously diagnosed multiple sclerosis (MS) were examined. Results Simulations indicated that the kurtosis of a signal-attenuation curve can determine if more than one water component is present and that care must be taken to select an appropriate threshold. It was possible to distinguish MS plaques in both signal and diffusional kurtosis maps, and in one patient, plaques of different degree of demyelinization showed different behavior. Discussion Our results indicate that in vivo q-space analysis is a potential tool for the assessment of different cerebral water components, and it might extend the diagnostic interpretation of data from diffusion magnetic resonance imaging.
  •  
8.
  •  
9.
  • Nilsson, Markus, et al. (författare)
  • Evaluating the accuracy and precision of a two-compartment Kärger model using Monte Carlo simulations.
  • 2010
  • Ingår i: Journal of Magnetic Resonance. - : Elsevier BV. - 1096-0856 .- 1090-7807. ; 206:1, s. 59-67
  • Tidskriftsartikel (refereegranskat)abstract
    • Specific parameters of the neuronal tissue microstructure, such as axonal diameters, membrane permeability and intracellular water fractions are assessable using diffusion MRI. These parameters are commonly estimated using analytical models, which may introduce bias in the estimated parameters due to the approximations made when deriving the models. As an alternative to using analytical models, a database of signal curves generated by fast Monte Carlo simulations can be employed. Simulated diffusion MRI measurements were generated and evaluated using the two-compartment Kärger model as well as the simulation model based on a database containing signal curves from approximately 60000 simulations performed with different combinations of microstructural parameters. A protocol based on a pulsed gradient spin echo sequence with diffusion times of 30 and 60ms and with gradient amplitudes obtainable with a clinical MRI scanner was employed for the investigations. When using the analytical model, a major negative bias (up to approximately 25%) in the estimated intracellular volume fraction was observed for short exchange times, while almost no bias was seen for the simulation model. In general, the simulation model improved the accuracy of the estimated parameters as compared to the analytical model, except for the exchange time parameter.
  •  
10.
  • Nilsson, Markus, et al. (författare)
  • On the effects of a varied diffusion time in vivo: is the diffusion in white matter restricted?
  • 2009
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 1873-5894 .- 0730-725X. ; 27:2008 Jul 25, s. 176-187
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this work was to study the diffusion-related signal attenuation curves (signal-vs.-b curves) measured perpendicular and parallel to the neuronal fibers of the corticospinal tract in vivo and to determine whether effects of restricted diffusion could be observed when varying the diffusion time (T(D)). A biexponential model and a two-compartment model including exchange according to the Kärger formalism were employed to analyze the signal-vs.-b curves. To validate the two-compartment model, restricted diffusion with exchange was simulated for uniformly sized cylinders, using different diameters and exchange times. The model was shown to retrieve the simulated parameters well, also when the short gradient pulse approximation was not met. The in vivo measurements performed perpendicular to the tracts, using b values up to 28000 s/mm(2) and T(D) values between 64 and 256 ms, did not show the effects of restricted diffusion as expected from previous ex vivo studies. The applied two-compartment model yielded an average axonal diameter of about 4 mum and an intracellular exchange time of about 300 ms, but did not fit statistically well to the data. In conclusion, this study indicates that if the diffusion is modeled as two compartments, of which one is restricted, exchange must be included in the model.
  •  
Skapa referenser, mejla, bekava och länka