1.
  • Brockstedt, Sara, et al. (författare)
  • Quantitative diffusion coefficient maps using fast spin-echo MRI
  • 1998
  • Ingår i: Magnetic Resonance Imaging. - 1873-5894. ; 16:8, s. 877-886
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence. The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes. Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients. The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written. Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28-50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo.
  •  
2.
  • Brockstedt, Sara, et al. (författare)
  • Triggering in quantitative diffusion imaging with single-shot EPI
  • 1999
  • Ingår i: Acta Radiologica. - 1600-0455. ; 40:3, s. 263-269
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion. MATERIAL AND METHODS: Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all. RESULTS: The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering. CONCLUSION: The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.
  •  
3.
  • Brockstedt, Sara, et al. (författare)
  • Use of an enhanced gradient system for diffusion MR imaging with motion-artifact reduction
  • 1995
  • Ingår i: Acta Radiologica. - 1600-0455. ; 36:6, s. 662-670
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: A spin-echo diffusion-sensitized pulse sequence using high gradients (23 mT/m) is introduced. MATERIAL AND METHODS: In order to minimize motion artefacts, velocity-compensating gradients, ECG-triggering and post-processing with phase correction and raw data averaging using navigator echoes was performed. The in vitro ratio of diffusion coefficients for water and acetone was determined and the water self-diffusion coefficient at different temperatures was evaluated. The pulse sequence was tested in 7 healthy volunteers and in 2 tumour patients with astrocytomas of grades I-II and III-IV. Both single-slice and multi-slice techniques were used. RESULTS: The incorporation of phase correction clearly improved the quality of both diffusion-encoded images and the calculated diffusion maps. Mean values of the diffusion coefficients in vivo were for CSF 2.66 x 10(-9) m2/s and for white and grey matter 0.69 x 10(-9) m2/s and 0.87 x 10(-9) m2/s, respectively. CONCLUSION: Velocity-compensating gradients in combination with a high gradient strength were shown to be useful for in vivo diffusion MR imaging.
  •  
4.
  • Geijer, Bo, et al. (författare)
  • Radiological diagnosis of acute stroke. Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging
  • 1999
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 40:3, s. 255-262
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare conventional MR imaging, echo-planar diffusion-weighted imaging (EP-DWI) and spin-echo diffusion-weighted imaging (SE)-DWI at radiological diagnosis of acute stroke. MATERIAL AND METHODS: Twenty-seven patients (30-85 years old) were examined. Clinical examination was performed before MR imaging. All MR examinations were assessed by an experienced neuroradiologist blinded to clinical findings. RESULTS: In EP-DWI, every patient had a lesion corresponding to the clinical findings. EP-DWI was used as the gold standard. In conventional PD+T2 imaging, 23/59 focal lesions were interpreted as acute, which was false in 11 lesions, and 36/59 lesions were considered to be old, 6 were in fact acute. Nine acute lesions were only detected retrospectively and 12 acute lesions were not detected at all on PD+T2. SE-DWI including the apparent diffusion coefficient correlated fairly well with EP-DWI but the procedure was impractical. CONCLUSION: EP-DWI is reliable for diagnosis of early ischemic stroke, while SE-DWI performs reasonably well. Conventional PD+T2 imaging is not reliable for diagnosis of early ischemia.
  •  
5.
  • Wirestam, Ronnie, et al. (författare)
  • The perfusion fraction in volunteers and in patients with ischaemic stroke
  • 1997
  • Ingår i: Acta Radiologica. - 1600-0455. ; 38:6, s. 961-964
  • Tidskriftsartikel (refereegranskat)abstract
    • The fractional volume of capillary blood, i.e. the perfusion fraction f, was measured with the aid of an echo-planar imaging protocol originally designed for the measurement of water diffusion. In healthy volunteers, reasonable f values were obtained. In patients with cerebral ischaemic stroke, a marked decrease in the f value was seen in the infarcted region as compared with corresponding values in the contralateral hemisphere. We suggest that perfusion-fraction measurements may add to the diagnostic value of water-mobility examinations in patients with ischaemic disease.
  •  
Skapa referenser, mejla, bekava och länka