SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brockstedt Sara) srt2:(2000-2004);pers:(Holtås Stig)"

Sökning: WFRF:(Brockstedt Sara) > (2000-2004) > Holtås Stig

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brockstedt, Sara, et al. (författare)
  • High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging
  • 2000
  • Ingår i: Magnetic Resonance Imaging. - 1873-5894. ; 18:6, s. 649-657
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).
  •  
2.
  •  
3.
  • Geijer, Bo, et al. (författare)
  • Persistent high signal on diffusion-weighted MRI in the late stages of small cortical and lacunar ischaemic lesions
  • 2001
  • Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 1432-1920 .- 0028-3940. ; 43:2, s. 115-122
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffusion-weighted imaging (DWI) is very sensitive to early brain infarcts. However, the late stages have been insufficiently studied. Infarcts in small vessel disease are often multiple and of different ages, and differentiation between new and old lesions might be difficult. We have therefore studied the change with time in DWI of small (< 3 ml) ischaemic lesions. We imaged 21 patients with an acute lacunar syndrome and a lesion visible on early DWI. They all had three MRI examinations 12-58 h (early), 7-16 and 54-144 days after the onset of stroke; 10 patients with high DWI signal on the third examination had a fourth examination 12-28 months after the stroke. MRI was performed at 1.5 T, using echo-planar DWI with 7 b-values from 0 to 1200 x 10(6) s/m2 and conventional T2-weighted imaging. After 7-16 days 18 of 21 lesions gave high signal on DWI, and 12/16 measurable lesions had a decreased apparent diffusion coefficient (ADC). After 54-144 days ten lesions still gave high DWI signal and two still had an ADC below normal. On the fourth examination there was no remaining high DWI signal and all ADC were higher than normal.
  •  
4.
  • Geijer, Bo, et al. (författare)
  • The value of b required to avoid T2 shine-through from old lucunar infarcts in diffusion-weighted imaging
  • 2001
  • Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 1432-1920 .- 0028-3940. ; 43:7, s. 511-517
  • Tidskriftsartikel (refereegranskat)abstract
    • Multiple small infarcts of different ages are common in small-vessel disease. Diffusion-weighted imaging (DWI) is a powerful method for discriminating new from chronic lesions. This can be done on the diffusion-weighted images provided that b is sufficiently high. Our purpose was to determine that critical value of b. We reviewed DWI from a previous study of acute, mainly lacunar strokes, and selected 18 old lacunar infarcts, well defined on uncoded images with b 0 s/m2 (i. e., T2-weighted images) but invisible on DWI with b 1,200 x 10(6) s/m2. We used a 1.5 tesla imager and single-shot echo-planar technique. We had seven separate acquisitions with echo time 123 ms and b in steps between 0 and 1,200 x 10(6) s/m2. Two neuroradiologists blinded to the selection of lesions carried out two different lesion-detection procedures, thereby testing each lesion four times, giving a total of 72 tests of b values. The results were consistent, indicating a level for detection of 800 x 10(6) s/m2 in two tests, 400-600 x 10(6) s/m2 in 65 tests and at lower values in the remainder. For imagers up to 1.5 tesla, at long repetition times and an echo time up to 120 ms T2-shine through of old lacunar infarcts can be avoided using b of 1,000 x 10(6) s/m2.
  •  
5.
  • Lindgren, Arne, et al. (författare)
  • Clinical lacunar syndromes as predictors of lacunar infarcts. A comparison of acute clinical lacunar syndromes and findings on diffusion-weighted MRI
  • 2000
  • Ingår i: Acta Neurologica Scandinavica. - : Hindawi Limited. - 1600-0404 .- 0001-6314. ; 101:2, s. 128-134
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To evaluate if patients with acute lacunar syndromes have acute lacunar infarcts or other types of cerebral lesions on diffusion-weighted MRI. METHODS: Patients with acute lacunar syndromes underwent echo-planar diffusion MRI of the brain within 3 days after stroke onset. Localization and size of lesions with hyperintense signal were determined, compared with clinical characteristics and with findings on follow-up T2-weighted MRI. RESULTS: Twenty-three patients participated in the study. Thirteen patients had pure motor stroke, 1 pure sensory stroke, 8 sensorimotor stroke, and 1 ataxic hemiparesis. Twenty-two patients had at least one lesion with increased signal on diffusion-weighted MR images. These acute lesions were in the internal capsule/ basal ganglia/thalamus in 13 patients, subcortical white matter in 5 patients, brainstem in 2 patients, cortex (multiple small lesions) in 1 patient, and cortex + basal ganglia in 1 patient. The median volume of the lesions was 0.6 ml on the initial examination and on follow-up, of 17 patients after 1 to 5 months, 0.5 ml. CONCLUSIONS: Almost all patients with acute ischemic lacunar syndromes have acute lesions on echo-planar diffusion-weighted MRI within 3 days after stroke onset. These lesions are mostly small and subcortical, compatible with lacunar infarcts caused by single penetrating artery occlusion, but in a minor proportion of patients (2 of 23 in our study) a cortical involvement is found.
  •  
6.
  • Wirestam, Ronnie, et al. (författare)
  • Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique
  • 2001
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 42:2, s. 123-128
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Perfusion-related parameters obtained by intravoxel incoherent motion (IVIM) MR imaging (MRI) were compared with cerebral blood volume and flow (CBV and CBF), retrieved by dynamic susceptibility-contrast (DSC) MRI. MATERIAL AND METHODS: Twenty-eight volunteers (average age 68.5 years) were investigated. Spin-echo echo-planar imaging with IVIM-encoding gradients was employed (36 different b values, 0-1200 s/mm2). The perfusion fraction and the pseudo-diffusion coefficient were calculated for regions in thalamus gray matter and frontal white matter, using asymptotic and full fitting. In DSC-MRI, a Gd-DTPA-BMA contrast-agent bolus was monitored using simultaneous-dual FLASH. Deconvolution of the measured tissue concentration-versus-time curve with an arterial input function from the carotid artery was applied, and maps of CBV and CBF were calculated. RESULTS: The correlation between the perfusion fraction and CBV was r=0.56 (p<0.0000006) using asymptotic fitting, and r=0.35 (p<0.0004) when full fitting was applied. Average CBF was 41.5 ml/(min 100 g), to be compared with the IVIM-based value of 63.6 ml/(min 100 g), obtained from the median value of the pseudo-diffusion coefficient in combination with assumptions about capillary network structure. CONCLUSION: The IVIM concept provided results that agreed reasonably with conventional CBV and CBF. The non-linear fitting to noisy signal data was problematic, in accordance with previously presented simulations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6
Typ av publikation
tidskriftsartikel (6)
Typ av innehåll
refereegranskat (6)
Författare/redaktör
Ståhlberg, Freddy (6)
Brockstedt, Sara (6)
Lindgren, Arne (5)
Geijer, Bo (4)
Sundgren, P.C. (1)
visa fler...
Borg, M (1)
Sundgren, Pia (1)
Norrving, Bo (1)
Wirestam, Ronnie (1)
Staaf, Gert (1)
Thomsen, C. (1)
Moore, J R (1)
visa färre...
Lärosäte
Lunds universitet (6)
Språk
Engelska (6)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy