Mapping the intracellular fraction of water by varying the gradient pulse length in q-space diffusion MRI
-
- Malmborg, Carin (författare)
- Lund University,Lunds universitet,Fysikalisk kemi,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Physical Chemistry,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Sjöbeck, Martin (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Brockstedt, Sara (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Englund, Elisabet (författare)
- Lund University,Lunds universitet,Tumörmikromiljö,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Tumor microenvironment,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Söderman, Olle (författare)
- Lund University,Lunds universitet,Fysikalisk kemi,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Physical Chemistry,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Topgaard, Daniel (författare)
- Lund University,Lunds universitet,Fysikalisk kemi,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Physical Chemistry,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2006
- 2006
- Engelska.
-
Ingår i: Journal of Magnetic Resonance. - : Elsevier BV. - 1096-0856 .- 1090-7807. ; 180:2, s. 280-285
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Finite gradient pulse lengths are traditionally considered a nuisance in q-space diffusion NMR and MRI, since the simple Fourier relation between the acquired signal and the displacement probability is invalidated. Increasing the value of the pulse length leads to an apparently smaller value of the estimated compartment size. We propose that q-space data at different gradient pulse lengths, but with the same effective diffusion time, can be used to identify and quantify components with free or restricted diffusion from multi-exponential echo decay curves obtained on cellular systems. The method is demonstrated with experiments on excised human brain white matter and a series of model systems with well-defined free, restricted, and combined free and restricted diffusion behavior. Time-resolved diffusion MRI experiments are used to map the spatial distribution of the intracellular fraction in a yeast cell suspension during sedimentation, and observe the disappearance of this fraction after a heat treatment. (c) 2006 Elsevier Inc. All rights reserved.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- imaging
- tissue
- PGSE
- pulsed field gradient
- SGP