SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bruze Magnus) ;pers:(Mowitz Martin)"

Sökning: WFRF:(Bruze Magnus) > Mowitz Martin

  • Resultat 1-10 av 52
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Aerts, Olivier, et al. (författare)
  • Isobornyl Acrylate
  • 2020
  • Ingår i: Dermatitis. - 1710-3568. ; 31:1, s. 4-12
  • Tidskriftsartikel (refereegranskat)abstract
    • Multidisciplinary collaboration between several European dermatology departments has identified isobornyl acrylate (IBOA; CAS 5888-33-5), once deemed a low-risk sensitizer, as a major culprit contact allergen in glucose sensors and insulin pumps, medical devices used by diabetes patients worldwide. Although the patch test modalities of IBOA have been fairly well characterized, intriguing questions remain. For example, its cross-reactive profile to other acrylates remains to be determined, and the striking occurrence of concomitant positive patch test reactions to sesquiterpene lactones needs to be further elucidated. Importantly, the path to its discovery as a contact sensitizer in diabetes devices and the difficulties that were associated with this quest illustrate that apparent difficulties in obtaining sufficient cooperation from the medical device industry may seriously hamper the correct workup of cases of allergic contact dermatitis. The IBOA saga will convince companies to lend more cooperation to dermatologists and policymakers to side with patients and physicians when it comes to updating medical device regulations, including the compulsory labeling of medical devices in general and of diabetes devices in particular.
  •  
4.
  • Alves da Silva, Catarina, et al. (författare)
  • Contact dermatitis in children caused by diabetes devices
  • 2022
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 87:5, s. 406-413
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Insulin pumps and glucose monitoring devices improve diabetes mellitus control and enhance patients' quality of life. However, a growing number of adverse cutaneous reactions related to the use of these devices have been reported. Objective: To investigate the culprits of localized contact dermatitis in paediatric patients with diabetes caused by insulin pumps and glucose monitoring devices. Methods: Retrospective analysis of 15 paediatric patients patch tested as part of a clinical investigation for skin reactions associated with insulin pumps and glucose monitoring devices. Results: Seven patients had positive patch test reactions to isobornyl acrylate (IBOA) and five had positive reactions to benzoyl peroxide (BP). Positive patch test reactions to materials from the glucose sensor and/or insulin pump were seen in 10 of the 15 patients. Three had positive reactions to adhesive remover wipe from Smith and Nephew Remove and four had reactions to EMLA plaster. Conclusion: A high share of patients showed positive reactions to IBOA and/or their medical devices (insulin pumps or glucose devices). A third of patients showed positive reactions to BP. The presence of additional unidentified allergens cannot be excluded, highlighting the importance of access to a full description of the chemical composition of the devices.
  •  
5.
  • Antelmi, Annarita, et al. (författare)
  • 4,4′-Thiobis(2-tert-butyl-5-methylphenol), an antioxidant in medical devices that may cause allergic contact dermatitis
  • 2023
  • Ingår i: Contact Dermatitis. - 0105-1873. ; 89:2, s. 103-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Antioxidants in medical devices, added to protect polymers or adhesives, may also cause contact dermatitis in some individuals. Objectives: To present data on sensitization to 4,4′-thiobis(2-tert-butyl-5-methylphenol), an antioxidant detected in some types of medical devices, for six patients that experienced eczematous reactions to different medical devices. Methods: Patch testing with 4,4′-thiobis(2-tert-butyl-5-methylphenol), 1% pet was performed. Gas chromatography-mass spectrometry (GC-MS) was used for identification of 4,4′-thiobis(2-tert-butyl-5-methylphenol) in different medical device products. Results: Six patients with contact allergy to 4,4′-thiobis(2-tert-butyl-5-methylphenol) also had relevant contact allergic reactions to medical devices containing the antioxidant. The presence of the antioxidant in products was detected using GC-MS analysis. Conclusions: The antioxidant 4,4′-thiobis(2-tert-butyl-5-methylphenol) may cause allergic contact dermatitis after exposure to different medical devices.
  •  
6.
  • Bruze, Magnus, et al. (författare)
  • A Retrospective Study of Aimed Patch Testing with Aqueous Nickel Sulfate Hexahydrate at 30% and 15% in Patients with Dermatitis
  • 2018
  • Ingår i: Dermatitis. - 1710-3568. ; 29:4, s. 193-195
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Sometimes, patients with a history of metal intolerance react negatively or doubtfully to nickel at patch testing. Objective The aim of the study was to investigate whether aqueous nickel sulfate hexahydrate at 15% and 30% traces more contact allergy than the nickel preparation in the baseline series at 5%. Methods In the period 1995-2015, more than 800 of 16,059 patients with a negative or doubtful patch test reaction to the petrolatum preparation of nickel at 5% on the day 3 reading were additionally tested with aqueous nickel at 15% and/or 30%. Conclusions In this retrospective study with aimed patch testing with aqueous nickel solutions, significantly more (P < 0.001) contact allergy was obtained as compared with the 5% preparation in petrolatum. The 30% solution was significantly better (P < 0.001) than the 15% solution. To demonstrate that patch testing with nickel at 15% or 30% is better than the present testing with 5% requires simultaneous testing with the 3 nickel preparations.
  •  
7.
  • Bruze, Magnus, et al. (författare)
  • Contact allergy to oxidised geraniol may be over-represented in individuals with photocontact allergy to ketoprofen
  • 2024
  • Ingår i: Contact Dermatitis. - 0105-1873. ; 90:1, s. 79-83
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Simultaneous overrepresentations of contact allergies and photocontact allergies are common in individuals with photocontact allergy to ketoprofen. Aims: To investigate whether contact allergy to oxidised (ox.) geraniol, geraniol, geranial, neral and citral is overrepresented in individuals with photocontact allergy to ketoprofen. Methods: The contact allergy rates to ox. geraniol, geraniol, geranial, neral and citral in routinely patch tested dermatitis patients were compared with the corresponding rates in individuals with photocontact allergy to ketoprofen. Results: Allergic patch test reactions were noted to ox. geraniol 11% (n = 39, 5.8%), ox. geraniol 6% (n = 12, 1.8%), geraniol 6% (n = 2, 0.3%), geranial (n = 18, 2.7%), neral (n = 7, 1.0%) and citral (n = 15, 2.2%). In those four patients who were diagnosed with photocontact allergy to ketoprofen during the test period, a significant overrepresentation (p = 0.020) of simultaneous contact allergy to ox. geraniol 11% was demonstrated. Overrepresentation of simultaneous contact allergy to various combinations of ox. geraniol, ox. limonene and ox. linalool was also noted in ketoprofen-photoallergic patients. Conclusions: Contact allergy to ox. geraniol, geranial and citral is common in routinely tested dermatitis patients. There is an overrepresentation of simultaneous contact allergy to ox. geraniol, ox. limonene and ox. linalool in patients with photocontact allergy to ketoprofen.
  •  
8.
  • Bruze, Magnus, et al. (författare)
  • Contact Allergy to Oxidized Linalool and Oxidized Limonene is Over-represented in Individuals with Photocontact Allergy to Ketoprofen
  • 2021
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 1651-2057. ; 101:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Simultaneous contact allergies are common in individuals with photocontact allergy to ketoprofen. The rate of contact allergy to the fragrance substances oxidized linalool and oxidized limonene in ketoprofen-photo-allergic individuals were investigated in comparison with the corresponding rates in individuals without photo-contact allergy to ketoprofen, using Fisher's exact test. A total of 4,021 patients were routinely tested with oxidized linalool; of whom 190 (4.7%) tested positively. For oxidized limonene the numbers were 3,797 patients and 111 positive reactions (2.9%). A total of 19 contact allergic reactions to oxidized linalool were noted in 29 patients (65.5%) who also had photocontact allergy to ketoprofen (p < 0.0001). The corresponding figures for oxidized limonene were 10 positive reactions in 24 ketoprofen-photoallergic individuals (41.7%) (p < 0.0001). Contact allergy to oxidized linalool and/or oxidized limonene is common in routinely tested patients with dermatitis and, particularly, in those patients who are photoallergic to ketoprofen.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 52

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy