SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bryan WL) "

Sökning: WFRF:(Bryan WL)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • Construction and performance of the PHENIX pad chambers
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 497:2-3, s. 263-293
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points along each track in the spectrometer arms at mid-rapidity and covers a total area of 88 m(2). Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising 172 800 electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Adcox, K, et al. (författare)
  • PHENIX central arm tracking detectors
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 489-507
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX tracking system consists of Drift Chambers (DC), Pad Chambers (PC) and the Time Expansion Chamber (TEC). PC1/DC and PC2/TEC/PC3 form the inner and outer tracking units, respectively. These units link the track segments that transverse the RICH and extend to the EMCal. The DC measures charged particle trajectories in the r-phi direction to determine P-T of the particles and the invariant mass of particle pairs. The PCs perform 3D spatial point measurements for pattern recognition and longitudinal momentum reconstruction and provide spatial resolution of a few mm in both r-phi and z. The TEC tracks particles passing through the region between the RICH and the EMCal. The design and operational parameters of the detectors are presented and running experience during the first year of data taking with PHENIX is discussed. The observed spatial and momentum resolution is given which imposes a limitation on the identification and characterization of charged particles in various momentum ranges. (C) 2002 Published by Elsevier Science B.V.
  •  
3.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
4.
  • Adler, SS, et al. (författare)
  • PHENIX on-line systems
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
5.
  •  
6.
  • 2021
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy