SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Carlsson E.) ;lar1:(kth)"

Sökning: WFRF:(Carlsson E.) > Kungliga Tekniska Högskolan

  • Resultat 1-10 av 36
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Menn, W., et al. (författare)
  • H, He, Li and Be Isotopes in the PAMELA-Experiment
  • 2016
  • Ingår i: INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2015), PTS 1-4. - : Institute of Physics (IOP).
  • Konferensbidrag (refereegranskat)abstract
    • On the 15th of June 2006, the PAMELA satellite-borne experiment was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anti-coincidence system, a shower tail counter scintillator and a neutron detector. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for antinuclei as well as the determination of light nuclei fluxes from hydrogen to oxygen in a wide energy range and with very high statistics. In this paper the identification capability for light nuclei isotopes using two different detector systems (Time-of-Flight and multiple dE/dx measurements in the calorimeter) and preliminary results of the isotopic ratios will be presented.
  •  
5.
  •  
6.
  • Appelgren, Patrik, et al. (författare)
  • Interaction between solid copper jets and powerful electrical current pulses
  • 2011
  • Ingår i: Journal of applied mechanics. - : ASME International. - 0021-8936 .- 1528-9036. ; 78:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction between a solid copper jet and an electric current pulse is studied. Copper jets that were created by a shaped-charge device were passed through an electrode configuration consisting of two aluminum plates with a separation distance of 150 mm. The electrodes were connected to a pulsed-power supply delivering a current pulse with amplitudes up to 250 kA. The current and voltages were measured, providing data on energy deposition in the jet and electrode contact region, and flash X-ray diagnostics were used to depict the jet during and after electrification. The shape of, and the velocity distributions along, the jet has been used to estimate the correlation between the jet mass flow through the electrodes and the electrical energy deposition. On average, 2.8 kJ/g was deposited in the jet and electrode region, which is sufficient to bring the jet up to the boiling point. A model based on the assumption of a homogenous current flow through the jet between the electrodes underestimates the energy deposition and the jet resistance by a factor 5 compared with the experiments, indicating a more complex current flow through the jet. The experimental results indicate the following mechanism for the enhancement of jet breakup. When electrified, the natural-formed necks in the jet are subjected to a higher current density compared with other parts of the jet. The higher current density results in a stronger heating and a stronger magnetic pinch force. Eventually, the jet material in the neck is evaporated and explodes electrically, resulting in a radial ejection of vaporized jet material.
  •  
7.
  • Barrios, C. A., et al. (författare)
  • GaAs/AlGaAs buried-heterostructure vertical-cavity surface-emitting laser with semi-insulating GalnP : Fe regrowth
  • 2000
  • Ingår i: Electronics Letters. - 0013-5194 .- 1350-911X. ; 36:18, s. 1542-1544
  • Tidskriftsartikel (refereegranskat)abstract
    • The authors report the first results of a GaAs/AlGaAs buried-heterostructure vertical-cavity surface-emitting laser (VCSEL) with semi-insulating Ga0.51In0.49P:Fe (SI-GaInP:Fe) as the burying layer. Regrowth of SI-GaInP:Fe around 15 mu m diameter and 8 mu m tall VCSEL mesas was carried out by hydride vapour phase epitaxy (HVPE). Under room temperature continuous wave (CW) operation. the device exhibited a threshold current of 3.5mA, a differential quantum efficency of 33% and a light output power of 4.2mW. CW operation at temperatures up to 97 degrees C is also demonstrated.
  •  
8.
  • Bauer, K., et al. (författare)
  • Welcome message from the PADE chairs
  • 2013
  • Ingår i: Welcome message from the PADE chairs  (Editorial). - : IEEE Computer Society. - 9781479905379 ; , s. lxi-lxii
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
9.
  • Bexell, U., et al. (författare)
  • A ToF-SIMS study of linseed oil bonded to mercapto silane treated aluminium
  • 2004
  • Ingår i: Applied Surface Science. - : Elsevier BV. - 0169-4332 .- 1873-5584. ; 231-2, s. 362-365
  • Tidskriftsartikel (refereegranskat)abstract
    • ToF-SIMS has been used to analyse an aluminium surface treated with a vegetable oil using a mercapto silane as a coupling agent between the aluminium substrate and the vegetable oil. The coupling between the vegetable oil and the mercapto silane was obtained through a photoinduced thiol-ene reaction using UV-radiation. The ToF-SIMS results show that the desired thiolene reaction has taken place between the unsaturated parts of the vegetable oil and the thiol groups of the mercapto silane via the thiol-ene reaction forming a surface film.
  •  
10.
  • Bielecki, Johan, 1982, et al. (författare)
  • Electrospray sample injection for single-particle imaging with x-ray lasers
  • 2019
  • Ingår i: Science advances. - : American Association for the Advancement of Science (AAAS). - 2375-2548. ; 5:5
  • Tidskriftsartikel (refereegranskat)abstract
    • The possibility of imaging single proteins constitutes an exciting challenge for x-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available x-ray lasers and, as we demonstrate here, contamination of the aerosolized molecules by nonvolatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet size during aerosolization. Here, we show that, with our electrospray injector, we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next-generation x-ray lasers, constitute an important stepping stone toward the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 36

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy