SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ceberg Crister) ;pers:(Behrens Claus F.)"

Sökning: WFRF:(Ceberg Crister) > Behrens Claus F.

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ottosson, Rickard, et al. (författare)
  • The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques
  • 2009
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 0284-186X .- 1651-226X. ; 48:2, s. 233-237
  • Tidskriftsartikel (refereegranskat)abstract
    • Pareto optimality is a concept that formalises the trade-off between a given set of mutually contradicting objectives. A solution is said to be Pareto optimal when it is not possible to improve one objective without deteriorating at least one of the other. A set of Pareto optimal solutions constitute the Pareto front. The Pareto concept applies well to the inverse planning process, which involves inherently contradictory objectives, high and uniform target dose on one hand, and sparing of surrounding tissue and nearby organs at risk (OAR) on the other. Due to the specific characteristics of a treatment planning system (TPS), treatment strategy or delivery technique, Pareto fronts for a given case are likely to differ. The aim of this study was to investigate the feasibility of using Pareto fronts as a comparative tool for TPSs, treatment strategies and delivery techniques. In order to sample Pareto fronts, multiple treatment plans with varying target conformity and dose sparing of OAR were created for a number of prostate and head neck IMRT cases. The DVHs of each plan were evaluated with respect to target coverage and dose to relevant OAR. Pareto fronts were successfully created for all studied cases. The results did indeed follow the definition of the Pareto concept, i.e. dose sparing of the OAR could not be improved without target coverage being impaired or vice versa. Furthermore, various treatment techniques resulted in distinguished and well separated Pareto fronts. Pareto fronts may be used to evaluate a number of parameters within radiotherapy. Examples are TPS optimization algorithms, the variation between accelerators or delivery techniques and the degradation of a plan during the treatment planning process. The issue of designing a model for unbiased comparison of parameters with such large inherent discrepancies, e.g. different TPSs, is problematic and should be carefully considered. fc.
  •  
2.
  • Stervik, Louise, 1993, et al. (författare)
  • Analysis of early respiratory-related mortality after radiation therapy of non-small-cell lung cancer : feasibility of automatic data extraction for dose–response studies
  • 2020
  • Ingår i: Acta Oncologica. - 0284-186X. ; 59:6, s. 628-635
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To examine the feasibility of automatic data extraction from clinical radiation therapy (RT) databases at four hospitals to investigate the impact of mean lung dose (MLD) and age on the risk of early respiratory-related death and early overall death for patients treated with RT for non-small-cell lung cancer (NSCLC). Material and methods: We included adult patients with NSCLC receiving curatively intended RT between 2002 and 2017 at four hospitals. A script was developed to automatically extract RT-related data. The cause of death for patients deceased within 180 days of the start of RT was retrospectively assessed. Using logistic regression, the risks of respiratory-related death and of overall death within 90 and 180 days were investigated using MLD and age as variables. Results: Altogether, 1785 patients were included in the analysis of early overall mortality and 1655 of early respiratory-related mortality. The respiratory-related mortalities within 90 and 180 days were 0.9% (15/1655) and 3.6% (60/1655). The overall mortalities within 90 and 180 days were 2.5% (45/1785) and 10.6% (190/1785). Higher MLD and older age were associated with an increased risk of respiratory-related death within 180 days and overall death within 90 and 180 days (all p<.05). For example, the risk of respiratory-related death within 180 days and their 95% confidence interval for patients aged 65 and 75 years with MLDs of 20 Gy was according to our logistic model 3.8% (2.6–5.0%) and 7.7% (5.5–10%), respectively. Conclusions: Automatic data extraction was successfully used to pool data from four hospitals. MLD and age were associated with the risk of respiratory-related death within 180 days of the start of RT and with overall death within 90 and 180 days. A model quantifying the risk of respiratory-related death within 180 days was formulated.
  •  
3.
  • Thor, Maria, et al. (författare)
  • Introducing multiple treatment plan-based comparison to investigate the performance of gantry angle optimisation (GAO) in IMRT for head and neck cancer
  • 2012
  • Ingår i: Acta Oncologica. - 1651-226X. ; 51:6, s. 743-751
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose. The purpose of this study was to evaluate the performance of gantry angle optimisation (GAO) compared to equidistant beam geometry for two inverse treatment planning systems (TPSs) by utilising the information obtained from a range of treatment plans. Material and methods. The comparison was based on treatment plans generated for four different head and neck (H&N) cancer cases using two inverse treatment planning systems (TPSs); Varian Eclipse (TM) representing dynamic MLC intensity modulated radiotherapy (IMRT) and Oncentra (R) Masterplan representing segmented MLC-based IMRT. The patient cases were selected on the criterion of representing different degrees of overlap between the planning target volume (PTV) and the investigated organ at risk, the ipsilateral parotid gland. For each case, a number of 'Pareto optimal' plans were generated in order to investigate the trade-off between the under-dosage to the PTV (V-PTV,V-D (< 95%)) or the decrease in dose homogeneity (D-5-D-95) to the PTV as a function of the mean absorbed dose to the ipsilateral parotid gland (< D >(parotid gland)). Results. For the Eclipse system, GAO had a clear advantage for the cases with smallest overlap (Cases 1 and 2). The set of data points, representing the underlying trade-offs, generated with and without using GAO were, however, not as clearly separated for the cases with larger overlap (Cases 3 and 4). With the OMP system, the difference was less pronounced for all cases. The Eclipse GAO displays the most favourable trade-off for all H&N cases. Conclusions. We have found differences in the effectiveness of GAO as compared to equidistant beam geometry, in terms of handling conflicting trade-offs for two commercial inverse TPSs. A comparison, based on a range of treatment plans, as developed in this study, is likely to improve the understanding of conflicting trade-offs and might apply to other thorough comparison techniques.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy