SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ceberg Crister) ;pers:(Capala J)"

Sökning: WFRF:(Ceberg Crister) > Capala J

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Capala, J, et al. (författare)
  • Boron neutron capture therapy for glioblastoma multiforme : Clinical studies in Sweden
  • 2003
  • Ingår i: Journal of Neuro-Oncology. - 1573-7373. ; 62:1, s. 135-144
  • Tidskriftsartikel (refereegranskat)abstract
    • A boron neutron capture therapy (BNCT) facility has been constructed at Studsvik, Sweden. It includes two filter/moderator configurations. One of the resulting neutron beams has been optimized for clinical irradiations with a filter/moderator system that allows easy variation of the neutron spectrum from the thermal to the epithermal energy range. The other beam has been designed to produce a large uniform field of thermal neutrons for radio-biological research. Scientific operations of the Studsvik BNCT project are overseen by the Scientific Advisory Board comprised of representatives of major universities in Sweden. Furthermore, special task groups for clinical and preclinical studies have been formed to facilitate collaboration with academia. The clinical Phase II trials for glioblastoma are sponsored by the Swedish National Neuro-Oncology Group and, presently, involve a protocol for BNCT treatment of glioblastoma patients who have not received any therapy other than surgery. In this protocol, p-boronophenylalanine (BPA), administered as a 6-h intravenous infusion, is used as the boron delivery agent. As of January 2002, 17 patients were treated. The 6-h infusion of 900 mg BPA/kg body weight was shown to be safe and resulted in the average blood-boron concentration of 24 μg/g (range: 15-32 μg/g) at the time of irradiation (approximately 2-3 h post-infusion). Peak and average weighted radiation doses to the brain were in the ranges of 8.0-15.5 Gy(W) and 3.3-6.1 Gy(W), respectively. So far, no severe BNCT-related acute toxicities have been observed. Due to the short follow-up time, it is too early to evaluate the efficacy of these studies.
  •  
2.
  • Munck af Rosenschöld, Per, et al. (författare)
  • Current status of dosimetry at the boron neutron capture therapy facility at Studsvik, Sweden
  • 2002
  • Ingår i: Research and Development in Neutron Capture Therapy. - 9788832329094 ; , s. 437-441
  • Konferensbidrag (refereegranskat)abstract
    • The beam was successfully characterized in air and in phantom using various radiation dosimeter:,. The determination of the thermal neutron and photon components of the mixed beam in phantom can be determined with acceptable uncertainties, while the uncertainty of the high-energy neutron component is considerable but of limited clinical significance. The beam intensity is sufficiently high for reasonably short treatment times. A novel approach to in-vivo dosimetry and quality assurance of treatment time in terms of monitor units was introduced in order to comply with national regulations regarding radiation therapy.
  •  