SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Conde L) ;mspu:(researchreview)"

Sökning: WFRF:(Conde L) > Forskningsöversikt

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Charles, E., et al. (författare)
  • Sensitivity projections for dark matter searches with the Fermi large area telescope
  • 2016
  • Ingår i: Physics reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 636, s. 1-46
  • Forskningsöversikt (refereegranskat)abstract
    • The nature of dark matter is a longstanding enigma of physics; it may consist of particles beyond the Standard Model that are still elusive to experiments. Among indirect search techniques, which look for stable products from the annihilation or decay of dark matter particles, or from axions coupling to high-energy photons, observations of the gamma-ray sky have come to prominence over the last few years, because of the excellent sensitivity of the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope mission. The LAT energy range from 20 meV to above 300 GeV is particularly well suited for searching for products of the interactions of dark matter particles. In this report we describe methods used to search for evidence of dark matter with the LAT, and review the status of searches performed with up to six years of LAT data. We also discuss the factors that determine the sensitivities of these searches, including the magnitudes of the signals and the relevant backgrounds, considering both statistical and systematic uncertainties. We project the expected sensitivities of each search method for 10 and 15 years of LAT data taking. In particular, we find that the sensitivity of searches targeting dwarf galaxies, which provide the best limits currently, will improve faster than the square root of observing time. Current LAT limits for dwarf galaxies using six years of data reach the thermal relic level for masses up to 120 GeV for the b (b) over bar annihilation channel for reasonable dark matter density profiles. With projected discoveries of additional dwarfs, these limits could extend to about 250 GeV. With as much as 15 years of LAT data these searches would be sensitive to dark matter annihilations at the thermal relic cross section for masses to greater than 400 GeV (200 GeV) in the b (b) over bar(tau(+)tau(-)) annihilation channels.
  •  
2.
  • Muysoms, F. E., et al. (författare)
  • European Hernia Society guidelines on the closure of abdominal wall incisions
  • 2015
  • Ingår i: Hernia. - : Springer Science and Business Media LLC. - 1265-4906 .- 1248-9204. ; 19:1, s. 1-24
  • Forskningsöversikt (refereegranskat)abstract
    • Background The material and the surgical technique used to close an abdominal wall incision are important determinants of the risk of developing an incisional hernia. Optimising closure of abdominal wall incisions holds a potential to prevent patients suffering from incisional hernias and for important costs savings in health care. Methods The European Hernia Society formed a Guidelines Development Group to provide guidelines for all surgical specialists who perform abdominal incisions in adult patients on the materials and methods used to close the abdominal wall. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II instrument. An update of these guidelines is planned for 2017. Results For many of the Key Questions that were studied no high quality data was detected. Therefore, some strong recommendations could be made but, for many Key Questions only weak recommendations or no recommendation could be made due to lack of sufficient evidence. Recommendations To decrease the incidence of incisional hernias it is strongly recommended to utilise a non-midline approach to a laparotomy whenever possible. For elective midline incisions, it is strongly recommended to perform a continuous suturing technique and to avoid the use of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method of fascial closure. Currently, no recommendations can be given on the optimal technique to close emergency laparotomy incisions. Prophylactic mesh augmentation appears effective and safe and can be suggested in high-risk patients, like aortic aneurysm surgery and obese patients. For laparoscopic surgery, it is suggested using the smallest trocar size adequate for the procedure and closure of the fascial defect if trocars larger or equal to 10 mm are used. For single incision laparoscopic surgery, we suggest meticulous closure of the fascial incision to avoid an increased risk of incisional hernias.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy