SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dalmo Johanna) ;lar1:(lu)"

Sökning: WFRF:(Dalmo Johanna) > Lunds universitet

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dalmo, Johanna, et al. (författare)
  • Evaluation of retinol binding protein 4 and carbamoylated haemoglobin as potential renal toxicity biomarkers in adult mice treated with Lu-177-octreotate
  • 2014
  • Ingår i: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 4:59
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The kidneys are regarded as one of the main dose-limiting organs in the treatment of neuroendocrine tumours with Lu-177-[DOTA(0), Tyr(3)]-octreotate (Lu-177-octreotate), despite the successful use of kidney uptake blocking agents such as lysine and arginine. To avoid renal toxicity but still give each patient as high amount of Lu-177-octreotate as possible, there is a need for methods/biomarkers that indicate renal injury in an early stage of the treatment. The aim of this study was to investigate the potential of using urinary retinol binding protein 4 (RBP4) and carbamoylated haemoglobin (Hb) in blood as biomarkers of nephrotoxic effects on adult mice after Lu-177-octreotate treatment. Methods: Adult BALB/c nude mice were injected with 60 MBq or 120 MBq of Lu-177-octreotate or with saline (control). Urine was collected before injection and concentrations of urinary RBP4 and creatinine were determined 14 to 90 days after injection Blood samples were collected after 90 days, and carbamoylated N-terminal valine in Hb, formed from urea, was measured as valine hydantoin (VH) after detachment from Hb. Results: The RBP4 values increased with administered activity and time. For the 60 and 120 MBq groups, statistically significantly higher RBP4 levels (p <0.05) were found at day 60 and 90 compared to baseline, also at day 30 for 120 MBq group. For VH, the mean values were similar for the 60 MBq and control groups, while a small increase was observed for the 120 MBq group; but there were no statistically significant differences between any of the groups (p >0.05). No morphological changes in the kidney tissue were found. Conclusions: Urinary RBP4 is a promising new biomarker for radiation-induced renal toxicity. For the conditions used in this experiment, carbamoylated Hb (from urea) measured as VH may not be a sufficiently sensitive biomarker to be used for renal toxicity.
  •  
2.
  • Hindorf, Cecilia, et al. (författare)
  • Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden
  • 2023
  • Ingår i: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 116
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The activity meter is used to determine the activity of delivered radiopharmaceuticals, administered activity to patients and reference activity when gamma-cameras are calibrated prior to imaged-based dosimetry. The aim is to describe a procedure for cross-calibration of activity meters at different clinical sites, and report on 177Lu activity results when using factory-set calibration factors compared to when calibration is performed with traceability to a primary standard.Methods: Thirty activity meters placed at seven hospitals in Norway and Sweden from four manufacturers: Capintec, Commecer, NuviaTech and Veenstra were included. A stock solution with 177Lu was prepared at the local sites and measured in each activity meter with factory settings. The solution was shipped to the reference site at Lund University for measurements in a secondary standard activity meter. Deviations between local and reference activity measurements were determined for three geometries: 25-mL vial, 10-mL syringe and 1-mL syringe.Results: The median of the deviations was 6.4 % for the 25 mL vial, 5.9 % for the 10 mL syringe and 6.8 % for the 1 mL syringe. The median of the deviations for the 25 mL vial, was 1.5 % for activity meters from Capintec, 7.0 % for Comecer, 11.0 % for NuviaTech and 2.4 % for Veenstra. The majority of the deviations were positive and the maximum deviation was 14.5 %.Conclusion: The activity of 177Lu measured in an activity meter with factory-set dial settings may yield deviations up to 14.5%, compared to activities measured with traceability to a primary standard. This would imply an undertreatment of patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy