SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Di Sciascio G) "

Sökning: WFRF:(Di Sciascio G)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aglietta, M, et al. (författare)
  • The cosmic ray proton, helium and CNO fluxes in the 100 TeV energy region from TeV muons and EAS atmospheric Cherenkov light observations of MACRO and EAS-TOP
  • 2004
  • Ingår i: Astroparticle physics. - Elsevier. - 0927-6505 .- 1873-2852. ; 21:3, s. 223-240
  • Tidskriftsartikel (refereegranskat)abstract
    • <p>The primary cosmic ray (CR) proton, helium and CNO fluxes in the energy range 80-300 TeV are studied at the National Gran Sasso Laboratories by means of EAS-TOP (Campo Imperatore, 2005 m a.s.l.) and MACRO (deep underground, 3100 m w.e., the surface energy threshold for a muon reaching the detector being E-mu(th) approximate to 1.3 TeV). The measurement is based on: (a) the selection of primaries based on their energy/nucleon (i.e., with energy/nucleon sufficient to produce a muon with energy larger than 1.3 TeV) and the reconstruction of the shower geometry by means of the muons recorded by MACRO in the deep underground laboratories; (b) the detection of the associated atmospheric Cherenkov light (C.l.) signals by means of the C.l. detector of EAS-TOP. The C.l. density at core distance r &gt; 100 m is directly related to the total primary energy E-0. Proton and helium ("p + He") and proton, helium and CNO ("p + He + CNO") primaries are thus selected at E-0 approximate to 80 TeV, and at E-0 similar or equal to 250 TeV, respectively. Their flux is measured: J(p+He)(80 TeV) = (1.8 +/- 0.4) x 10(-6) m(-1)-s(-1) sr(-1) TeV-1, and J(p+He+CNO)(250 TeV) = (1.1 +/- 0.3) x 10(-7) m(-2)-s(-1) sr(-1) TeV-1, their relative weights being J(p+He)(J(p+He+CNO)) over bar (250 TeV) = 0.78 +/- 0.17. By using the measurements of the proton spectrum obtained from the direct experiments and hadron flux data in the atmosphere, we obtain for the relative weights of the three components at 250 TeV: J(p) : J(He) : J(CNO) = (0.20 +/- 0.08) : (0.58 +/- 0.19) : (0.22 +/- 0.17). This corresponds to the dominance of helium over proton primaries at 100-1000 TeV, and a possible non-negligible contribution from CNO. The lateral distribution of Cherenkov light in Extensive Air Showers (EASs), which is related to the rate of energy deposit of the primary in the atmosphere, is measured for a selected proton and helium primary beam, and good agreement is found when compared with the one calculated with the CORSIKA/QGSJET simulation model. (C) 2004 Elsevier B.V. All rights reserved.</p>
  •  
2.
  • Sarchiapone, Marco, et al. (författare)
  • EUDOR-A multi-centre research program : : A naturalistic, European Multi-centre Clinical study of EDOR Test in adult patients with primary depression
  • 2017
  • Ingår i: BMC Psychiatry. - BioMed Central (BMC). - 1471-244X. ; 17:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Electrodermal reactivity has been successfully used as indicator of interest, curiosity as well as depressive states. The measured reactivity depends on the quantity of sweat secreted by those eccrine sweat glands that are located in the hypodermis of palmar and plantar regions. Electrodermal hyporeactive individuals are those who show an unusual rapid habituation to identical non-significant stimuli. Previous findings suggested that electrodermal hyporeactivity has a high sensitivity and a high specificity for suicide. The aims of the present study are to test the effectiveness and the usefulness of the EDOR (ElectroDermal Orienting Reactivity) Test as a support in the suicide risk assessment of depressed patients and to assess the predictive value of electrodermal hyporeactivity, measured through the EDOR Test, for suicide and suicide attempt in adult patients with a primary diagnosis of depression. Methods and design: 1573 patients with a primary diagnosis of depression, whether currently depressed or in remission, have been recruited at 15 centres in 9 different European countries. Depressive symptomatology was evaluated through the Montgomery-Asberg Depression Scale. Previous suicide attempts were registered and the suicide intent of the worst attempt was rated according to the first eight items of the Beck Suicide Intent Scale. The suicide risk was also assessed according to rules and traditions at the centre. The EDOR Test was finally performed. During the EDOR Test, two fingers are put on gold electrodes and direct current of 0.5 V is passed through the epidermis of the fingers according to standards. A moderately strong tone is presented through headphones now and then during the test. The electrodermal responses to the stimuli represent an increase in the conductance due to the increased number of filled sweat ducts that act as conductors through the electrically highly resistant epidermis. Each patient is followed up for one year in order to assess the occurrence of intentional self-harm. Discussion: Based on previous studies, expected results would be that patients realizing a suicide attempt with a strong intent or committing suicide should be electrodermally hyporeactive in most cases and non-hyporeactive patients should show only few indications of death intent or suicides. Trial registration: The German Clinical Trials Register, DRKS00010082. Registered May 31st, 2016. Retrospectively registered.
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy