1.
  • Bäcklund, Nils, et al. (författare)
  • Reference intervals of salivary cortisol and cortisone and their diagnostic accuracy in Cushing's syndrome
  • 2020
  • Ingår i: European Journal of Endocrinology. - : Bioscientifica. - 0804-4643 .- 1479-683X. ; 182:6, s. 569-582
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The challenge of diagnosing Cushing's syndrome (CS) calls for high precision biochemical screening. This study aimed to establish robust reference intervals for, and compare the diagnostic accuracy of, salivary cortisol and cortisone in late-night samples and after a low-dose (1 mg) dexamethasone suppression test (DST). Design and methods: Saliva samples were collected at 08:00 and 23:00 h, and at 08:00 h, after a DST, from 22 patients with CS and from 155 adult reference subjects. We also collected samples at 20:00 and 22:00 h from 78 of the reference subjects. Salivary cortisol and cortisone were analysed with liquid chromatography-tandem mass spectrometry. The reference intervals were calculated as the 2.5th and 97.5th percentiles of the reference population measurements. Diagnostic accuracies of different tests were compared, based on areas under the receiver-operating characteristic curves. Results: The upper reference limits of salivary cortisol and cortisone at 23:00 h were 3.6 nmol/L and 13.5 nmol/L, respectively. Using these reference limits, CS was detected with a sensitivity (95% CI) of 90% (70-99%) and specificity of 96% (91-98%) for cortisol, and a 100% (84-100%) sensitivity and 95% (90-98%) specificity for cortisone. After DST, cortisol and cortisone upper reference limits were 0.79 nmol/L and 3.5 nmol/L, respectively. CS was detected with 95% (75-100%) sensitivity and 96% (92-99%) specificity with cortisol, and 100% (83-100%) sensitivity and 94% (89-97%) specificity with cortisone. No differences in salivary cortisol or cortisone levels were found between samples collected at 22:00 and 23:00 h. Conclusion: Salivary cortisol and cortisone in late-night samples and after DST showed high accuracy for diagnosing CS, salivary cortisone being slightly, but significantly better. © 2020 European Society of Endocrinology Printed in Great Britain.
  •  
2.
  • Bäcklund, Nils, et al. (författare)
  • Salivary cortisol and cortisone in diagnosis of Cushing's syndrome - a comparison of six different analytical methods
  • 2023
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 61:10, s. 1780-1791
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Salivary cortisol and cortisone at late night and after dexamethasone suppression test (DST) are increasingly used for screening of Cushing's syndrome (CS). We aimed to establish reference intervals for salivary cortisol and cortisone with three liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques and for salivary cortisol with three immunoassays (IAs), and evaluate their diagnostic accuracy for CS.Methods: Salivary samples at 08:00 h, 23:00 h and 08:00 h after a 1-mg DST were collected from a reference population (n=155) and patients with CS (n=22). Sample aliquots were analyzed by three LC-MS/MS and three IA methods. After establishing reference intervals, the upper reference limit (URL) for each method was used to calculate sensitivity and specificity for CS. Diagnostic accuracy was evaluated by comparing ROC curves.Results: URLs for salivary cortisol at 23:00 h were similar for the LC-MS/MS methods (3.4-3.9 nmol/L), but varied between IAs: Roche (5.8 nmol/L), Salimetrics (4.3 nmol/L), Cisbio (21.6 nmol/L). Corresponding URLs after DST were 0.7-1.0, and 2.4, 4.0 and 5.4 nmol/L, respectively. Salivary cortisone URLs were 13.5-16.6 nmol/L at 23:00 h and 3.0-3.5 nmol/L at 08:00 h after DST. All methods had ROC AUCs =0.96.Conclusions: We present robust reference intervals for salivary cortisol and cortisone at 08:00 h, 23:00 h and 08:00 h after DST for several clinically used methods. The similarities between LC-MS/MS methods allows for direct comparison of absolute values. Diagnostic accuracy for CS was high for all salivary cortisol and cortisone LC-MS/MS methods and salivary cortisol IAs evaluated.
  •  