SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fransson Torsten) ;pers:(El Gabry Lamyaa)"

Sökning: WFRF:(Fransson Torsten) > El Gabry Lamyaa

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • El-Gabry, Lamyaa, et al. (författare)
  • Measurements of Hub Flow Interaction on Film Cooled Nozzle Guide Vane in Transonic Annular Cascade
  • 2015
  • Ingår i: Journal of turbomachinery. - : ASME International. - 0889-504X .- 1528-8900. ; 137:8
  • Tidskriftsartikel (refereegranskat)abstract
    • An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes (NGVs) to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge (TE) can be used to visualize the mixing of the coolant flow with the mainstream. Flow field measurements are performed in the downstream plane with a five-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side (PS) of the vane TE where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge (LE) does not reach the PS endwall, potentially creating a local hotspot.
  •  
2.
  • El-Gabry, Lamyaa, et al. (författare)
  • Measurements of Hub Flow Interaction on Film Cooled Nozzle Guide Vane in Transonic Annular Cascade
  • 2012
  • Ingår i: Proceedings of the ASME Turbo Expo. - : ASME Press. - 9780791844748
  • Konferensbidrag (refereegranskat)abstract
    • An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge can be used to visualize the mixing of the coolant flow with the mainstream.Flow field measurements are performed in the downstream plane with a 5-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side of the vane trailing edge where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge does not reach the pressure side endwall, potentially creating a local hotspot.
  •  
3.
  • Siddique, Waseem, et al. (författare)
  • Design of internally cooled trailing edge at engine similar conditions- A conjugate heat transfer problem
  • 2012
  • Ingår i: ASME Turbo Expo 2012. - NEW YORK : ASME Press. - 9780791844700 ; , s. 1357-1372, s. 1357-1372
  • Konferensbidrag (refereegranskat)abstract
    • Gas turbines are operated at elevated temperatures as the thermal efficiency of the gas turbine is directly linked to the turbine inlet gas temperature. The different regions of the turbine blade require different means of cooling. This paper presents different designs of the two-pass trapezoidal channel which represents the trailing edge of a real engine. Engine similar boundary conditions are applied and conjugate heat transfer method is used to predict the wall temperatures. The aim is to design a cooling channel that through use of steam can reduce wall temperatures to below a target value while maintaining minimal pressure drop. The variations in design of a smooth two-pass channel were made to achieve the design target. These variations included installation of ribs at the walls, tapered divider wall, tilted divider wall and L-shaped divider wall to promote fluid impingement on the trailing wall. The results suggest that a channel with staggered ribs at the outlet pass, a tilted divider wall and impingement at the corner is the best arrangement for reducing wall temperatures below the target value; however, it has low overall aerothermal performance due to high pressure losses. A similar channel without impingement can yield acceptable results if a thermal barrier coating is applied or if a small corner of the tip-trailing edge is truncated to reduce material volume. This modification though can improve the thermal performance of the channel, is to result in higher profile and aerodynamics losses.
  •  
4.
  • Siddique, Waseem, et al. (författare)
  • Flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular smooth channels
  • 2012
  • Ingår i: Heat and Mass Transfer. - : Springer Science and Business Media LLC. - 0947-7411 .- 1432-1181. ; 48:5, s. 735-748
  • Tidskriftsartikel (refereegranskat)abstract
    • Two-pass channels are used for internal cooling in a number of engineering systems e.g., gas turbines. Fluid travelling through the curved path, experiences pressure and centrifugal forces, that result in pressure driven secondary motion. This motion helps in moving the cold high momentum fluid from the channel core to the side walls and plays a significant role in the heat transfer in the channel bend and outlet pass. The present study investigates using Computational Fluid Dynamics (CFD), the flow structure, heat transfer enhancement and pressure drop in a smooth channel with varying aspect ratio channel at different divider-to-tip wall distances. Numerical simulations are performed in two-pass smooth channel with aspect ratio W-in/H = 1:3 at inlet pass and W-out/H = 1:1 at outlet pass for a variety of divider-to-tip wall distances. The results show that with a decrease in aspect ratio of inlet pass of the channel, pressure loss decreases. The divider-to-tip wall distance (W-el) not only influences the pressure drop, but also the heat transfer enhancement at the bend and outlet pass. With an increase in the divider-to-tip wall distance, the areas of enhanced heat transfer shifts from side walls of outlet pass towards the inlet pass. To compromise between heat transfer and pressure drop in the channel, W-el/H = 0.88 is found to be optimum for the channel under study.
  •  
5.
  • Siddique, Waseem, et al. (författare)
  • On flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular channel with ribs at 45 degrees
  • 2013
  • Ingår i: Heat and Mass Transfer. - : Springer Science and Business Media LLC. - 0947-7411 .- 1432-1181. ; 49:5, s. 679-694
  • Tidskriftsartikel (refereegranskat)abstract
    • To increase the thermal efficiency of gas turbines, inlet temperature of gas is increased. This results in the requirement of cooling of gas turbine blades and vanes. Internal cooling of gas turbine blades and vanes is one of several options. Two-pass channels are provided with ribs to enhance heat transfer at the expense of an increased pressure drop. The space in the blade is limited and requires channels with small aspect ratios. Numerical simulations have been performed to investigate heat transfer, flow field and pressure loss in a two-pass channel equipped with 45A degrees ribs with aspect ratio (W-in/H) equal to 1:3 in the inlet pass and 1:1 in the outlet pass with both connected together with a 180A degrees bend. The results are compared with a higher aspect ratio channel (W-in/H = 1:2, inlet pass). In the ribbed channel, a decrease in pressure drop was observed with a decrease in the aspect ratio of the channel. The smaller aspect ratio channel not only allows using more cooling channels in the blade, but also results in more heat transfer enhancement. The divider-to-tip wall distance (W-el) has influence on the pressure drop, as well as on the heat transfer enhancement at the bend and outlet pass. Heat transfer decreases with decrease in aspect ratio of the inlet pass of the two-pass channel. With increase in divider-to-tip wall distance, heat transfer tries to attain a constant value.
  •  
6.
  • Siddique, Waseem, et al. (författare)
  • Validation and Analysis of Numerical Results for a Two-Pass Trapezoidal Channel With Different Cooling Configurations of Trailing Edge
  • 2012
  • Ingår i: Journal of turbomachinery. - : ASME International. - 0889-504X .- 1528-8900. ; 135:1, s. 011027-
  • Tidskriftsartikel (refereegranskat)abstract
    • High inlet temperatures in a gas turbine lead to an increase in the thermal efficiency of the gas turbine. This results in the requirement of cooling of gas turbine blades/vanes. Internal cooling of the gas turbine blade/vanes with the help of two-pass channels is one of the effective methods to reduce the metal temperatures. In particular, the trailing edge of a turbine vane is a critical area, where effective cooling is required. The trailing edge can be modeled as a trapezoidal channel. This paper describes the numerical validation of the heat transfer and pressure drop in a trapezoidal channel with and without orthogonal ribs at the bottom surface. A new concept of ribbed trailing edge has been introduced in this paper which presents a numerical study of several trailing edge cooling configurations based on the placement of ribs at different walls. The baseline geometries are two-pass trapezoidal channels with and without orthogonal ribs at the bottom surface of the channel. Ribs induce secondary flow which results in enhancement of heat transfer; therefore, for enhancement of heat transfer at the trailing edge, ribs are placed at the trailing edge surface in three different configurations: first without ribs at the bottom surface, then ribs at the trailing edge surface in-line with the ribs at the bottom surface, and finally staggered ribs. Heat transfer and pressure drop is calculated at Reynolds number equal to 9400 for all configurations. Different turbulent models are used for the validation of the numerical results. For the smooth channel low-Re k-e model, realizable k-e model, the RNG k-ω model, low-Re k-ω model, and SST k-ω models are compared, whereas for ribbed channel, low-Re k-e model and SST k-ω models are compared. The results show that the low-Re k-e model, which predicts the heat transfer in outlet pass of the smooth channels with difference of +7%, underpredicts the heat transfer by -17% in case of ribbed channel compared to experimental data. Using the same turbulence model shows that the height of ribs used in the study is not suitable for inducing secondary flow. Also, the orthogonal rib does not strengthen the secondary flow rotational momentum. The comparison between the new designs for trailing edge shows that if pressure drop is acceptable, staggered arrangement is suitable for the outlet pass heat transfer. For the trailing edge wall, the thermal performance for the ribbed trailing edge only was found about 8% better than other configurations.
  •  
7.
  • Siddique, Waseem, et al. (författare)
  • Validation and analysis of numerical results for a two-pass trapezoidal channel with different cooling configurations of trailing edge
  • 2012
  • Ingår i: Proceedings of the ASME Turbo Expo 2011, Vol 5, Parts A And B. - : American Society Of Mechanical Engineers. - 9780791854655 ; , s. 1571-1581
  • Konferensbidrag (refereegranskat)abstract
    • High inlet temperatures in a gas turbine lead to an increase in the thermal efficiency of the gas turbine. This results in the requirement of cooling of gas turbine blades/vanes. Internal cooling of the gas turbine blade/vanes with the help of two-pass channels is one of the effective methods to reduce the metal temperatures. Especially the trailing edge of a turbine vane is a critical area, where effective cooling is required. The trailing edge can be modeled as a trapezoidal channel. This paper describes the numerical validation of the heat transfer and pressure drop in a trapezoidal channel with and without orthogonal ribs at the bottom surface. A new concept of ribbed trailing edge has been introduced in this paper which presents a numerical study of several trailing edge cooling configurations based on the placement of ribs at different walls. The baseline geometries are two-pass trapezoidal channels with and without orthogonal ribs at the bottom surface of the channel. Ribs induce secondary flow which results in enhancement of heat transfer therefore for enhancement of heat transfer at the trailing edge, ribs are placed at the trailing edge surface in three different configurations: first without ribs at the bottom surface, then ribs at trailing edge surface in-line with the ribs at bottom surface and finally staggered ribs. Heat transfer and pressure drop is calculated at Reynolds number equal to 9400 for all configurations. Different turbulent models are used for the validation of the numerical results. For the smooth channel low-Re kappa-epsilon model, realizable kappa-epsilon model, the RNG kappa-omega model, low-Re kappa-omega model and SST kappa-omega models are compared, whereas for ribbed channel low-Re kappa-omega model and SST kappa-omega models are compared. The results show that the low-Re k-epsilon model, which predicts the heat transfer in outlet pass of the smooth channels with difference of +7%, underpredicts the heat transfer by -17% in case of ribbed channel compared to experimental data. Using the same turbulence model shows that the height of ribs used in the study is not suitable for inducing secondary flow. Also, the orthogonal rib does not strengthen the secondary flow rotational momentum. The comparison between the new designs for trailing edge shows that if pressure drop is acceptable, staggered arrangement is suitable for the outlet pass heat transfer. For the trailing edge wall, the thermal performancefor ribbed trailing edge only, was found about 8% better than other configurations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy