On a new method to assess the accuracy of a CAD program.

Dahlmo, K I (author)
Procera Technical Support, Nobel Biocare, Göteborg, Sweden
Andersson, M (author)
Procera Research and Development, Nobel Biocare, Göteborg, Sweden
Gellerstedt, Martin, 1966- (author)
Högskolan Väst,Institutionen för ekonomi och it,Univ. of Trollhättan/Uddevalla, Uddevalla, Sweden
show more...
Karlsson, S (author)
show less...
 (creator_code:org_t)
Quintessence Publishing, 2001
2001
English.
In: International Journal of Prosthodontics. - : Quintessence Publishing. - 0893-2174 .- 1139-9791. ; 14:3, s. 276-83
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: This study was initiated with the purpose of developing and evaluating a system for measuring the magnitude of the variation between a computer-aided design (CAD) object created on the computer screen and a replicated object produced by computer-aided manufacturing (CAM). MATERIALS AND METHODS: Controlled geometric forms, a square and a cone, were designed in a CAD program, and measuring distances were selected. The CAD data were transmitted to CAM data, and objects were produced. The CAD/CAM process was the Procera system, and the holder system permitted the objects to be ground into cross sections, similar to the visualization in the CAD program. Five objects of each shape were produced and measured by two operators two times. Three operators measured one of the objects 30 times. RESULTS: Observed values were greater than the true value. For all objects, the systematic error was at most 15.5 microns. Interoperator difference was small. The variation because of measurement error was greater for the square object compared to the cone. However, the variation because of object was higher for the cone object than for the square. The total standard deviation was 7.7 microns. Thus, the total random error caused by object variation and measurement error was in approximately 95% of all measurements less than 15 microns. CONCLUSION: There are no differences in the measurement data derived from this method and actual measurement data from an object created by the computer-aided dental design program. The method has high validity and reliability, i.e., high accuracy.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Annan teknik -- Interaktionsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies -- Interaction Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

Analysis of Variance
Vårdvetenskap
Nursing science
Informatics
Informatik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Dahlmo, K I
Andersson, M
Gellerstedt, Mar ...
Karlsson, S
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Other Engineerin ...
and Interaction Tech ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
International Jo ...
By the university
University West
University of Skövde

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view