SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hebert J) ;hsvcat:2"

Sökning: WFRF:(Hebert J) > Teknik

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cheng, Kimberley, et al. (författare)
  • Rapana thomasiana hemocyanin (RtH): Comparison of the two isoforms, RtH1 and RtH2, at 19 angstrom 16 angstrom resolution
  • 2006
  • Ingår i: Micron. - : Elsevier BV. - 0968-4328 .- 1878-4291. ; 37:6, s. 566-576
  • Forskningsöversikt (refereegranskat)abstract
    • Three-dimensional (3D) reconstructions of the two 8.4 MDa Rapana thomasiana hemocyanin isoforms, RtH1 and RtH2, have been obtained by cryoelectron microscopy of molecules embedded in vitreous ice and single particle image processing. The final 3D structures of the RtH1 and RtH2 didecamers at 19 angstrom and 16 angstrom resolution, respectively, are very similar to earlier reconstructions of gastropodan hemocyanins, revealing structural features such as the obliquely oriented subunits, the five- and two-fold symmetrical axes. Three new interactions are defined; two of them connecting the arch and the wall while the third is formed between the collar and the wall. The collar-wall connection and one of the arch-wall connections are positioned between two individual subunit dimers, while the second arch-wall connection is located between two subunits within the subunit dimer. All three interactions establish connections to the first tier of the wall. Furthermore, for each interaction we have allocated two first tier functional units most likely involved in forming the connections. (
  •  
2.
  • Härmark, Johan, et al. (författare)
  • Shell thickness determination of polymer-shelled microbubbles using transmission electron microscopy
  • 2016
  • Ingår i: Micron. - : Elsevier. - 0968-4328 .- 1878-4291. ; 85, s. 39-43
  • Tidskriftsartikel (refereegranskat)abstract
    • Intravenously injected microbubbles (MBs) can be utilized as ultrasound contrast agent (CA) resulting in enhanced image quality. A novel CA, consisting of air filled MBs stabilized with a shell of polyvinyl alcohol (PVA) has been developed. These spherical MBs have been decorated with superparamagnetic iron oxide nanoparticles (SPIONs) in order to serve as both ultrasound and magnetic resonance imaging (MRI) CA. In this study, a mathematical model was introduced that determined the shell thickness of two types of SPIONs decorated MBs (Type A and Type B). The shell thickness of MBs is important to determine, as it affects the acoustical properties. In order to investigate the shell thickness, thin sections of plastic embedded MBs were prepared and imaged using transmission electron microscopy (TEM). However, the sections were cut at random distances from the MB center, which affected the observed shell thickness. Hence, the model determined the average shell thickness of the MBs from corrected mean values of the outer and inner radii observed in the TEM sections. The model was validated using simulated slices of MBs with known shell thickness and radius. The average shell thickness of Type A and Type B MBs were 651nm and 637nm, respectively.
  •  
3.
  • Lancaster, D. G., et al. (författare)
  • An ultra-stable 2.9 mu m guided-wave chip laser and application to nano-spectroscopy
  • 2019
  • Ingår i: APL Photonics. - : AIP Publishing. - 2378-0967. ; 4:11
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a configurable guided-wave planar glass-chip laser that produces low-noise and high-quality continuous-wave laser emission tunable from 2.82 to 2.95 mu m. The laser has a low threshold and intrinsic power and mode stability attributable to the high overlap of gain volume and pump mode defined by an ultrafast laser inscribed waveguide. The laser emission is single transverse-mode with a Gaussian spatial profile and M-x,y(2) similar to 1.05, 1.10. The power drift is similar to 0.08% rms over similar to 2 h. When configured in a spectrally free-running cavity, the guided-wave laser emits up to 170 mW. The benefit of low-noise and stable wavelength emission of this hydroxide resonant laser is demonstrated by acquiring high signal-to-noise images and spectroscopy of a corroded copper surface film with corrosion products containing water and hydroxide ions with a scattering-scanning near-field optical microscope.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy