SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Herrmann Björn) ;pers:(Olcén P.)"

Sökning: WFRF:(Herrmann Björn) > Olcén P.

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdeldaim, Guma, et al. (författare)
  • Is quantitative PCR for the pneumolysin (ply) gene useful for detection of pneumococcal lower respiratory tract infection?
  • 2009
  • Ingår i: Clinical Microbiology and Infection. - : Elsevier BV. - 1198-743X .- 1469-0691. ; 15:6, s. 565-570
  • Tidskriftsartikel (refereegranskat)abstract
    • The pneumolysin (ply) gene is widely used as a target in PCR assays for Streptococcus pneumoniae in respiratory secretions. However, false-positive results with conventional ply-based PCR have been reported. The aim here was to study the performance of a quantitative ply-based PCR for the identification of pneumococcal lower respiratory tract infection (LRTI). In a prospective study, fibreoptic bronchoscopy was performed in 156 hospitalized adult patients with LRTI and 31 controls who underwent bronchoscopy because of suspicion of malignancy. Among the LRTI patients and controls, the quantitative ply-based PCR applied to bronchoalveolar lavage (BAL) fluid was positive at >/=10(3) genome copies/mL in 61% and 71% of the subjects, at >/=10(5) genome copies/mL in 40% and 58% of the subjects, and at >/=10(7) genome copies/mL in 15% and 3.2% of the subjects, respectively. Using BAL fluid culture, blood culture, and/or a urinary antigen test, S. pneumoniae was identified in 19 LRTI patients. As compared with these diagnostic methods used in combination, quantitative ply-based PCR showed sensitivities and specificities of 89% and 43% at a cut-off of 10(3) genome copies/mL, of 84% and 66% at a cut-off of 10(5) genome copies/mL, and of 53% and 90% at a cut-off of 10(7) genome copies/mL, respectively. In conclusion, a high cut-off with the quantitative ply-based PCR was required to reach acceptable specificity. However, as a high cut-off resulted in low sensitivity, quantitative ply-based PCR does not appear to be clinically useful. Quantitative PCR methods for S. pneumoniae using alternative gene targets should be evaluated.
  •  
2.
  • Unemo, M, et al. (författare)
  • Experiences with the new genetic variant of Chlamydia trachomatis in Orebro county, Sweden - proportion, characteristics and effective diagnostic solution in an emergent situation
  • 2007
  • Ingår i: Eurosurveillance. - 1560-7917 .- 1025-496X. ; 12:4
  • Tidskriftsartikel (refereegranskat)abstract
    • A Chlamydia trachomatis variant that contains a 377 bp deletion in the cryptic plasmid was recently reported in Sweden. This deletion includes the targets for Cobas Amplicor, Cobas TaqMan48, and Abbott m2000. We examined the proportion and characteristics of this variant in Örebro county, Sweden and developed an effective diagnostic solution. In total, 2,401 consecutive C. trachomatis culture samples and 536 PCR samples from symptomatic and asymptomatic patients and screened females were included. Culture, Cobas Amplicor, and LightMix 480HT were used for diagnosis. A mutant-specific PCR, plasmid sequencing, omp1 sequencing and multilocus sequence typing (MLST) were used to identify and characterise mutants. In total, 162 (6.7%) of the cultured samples were positive for C. trachomatis. However, 61 (38%) of those were negative when using Cobas Amplicor, and 60 of these were subsequently confirmed as the new variant. 13 of these mutant isolates were further characterised genetically, and all were of identical genotype E and the unique MLST sequence type: 21, 19, 1, 2, 1. Of all culture-positive samples, 161 of 162 were positive in the LightMix 480HT assay. The single negative sample was only weakly positive in culture, and negative in all PCRs. Of the 536 PCR samples, 37 were positive in both Cobas Amplicor and LightMix 480HT, 13 were only positive in LightMix 480HT (mutants), and two were only positive in Cobas Amplicor. Mutated C. trachomatis were prevalent in Örebro county in the period from October 2006 to February 2007, and it appeared to be a single clone. LightMix 480HT seemed sensitive, specific, and enabled high throughput diagnostics. However, rare low positive samples may be false-negative. Frequent surveillance and evaluations of diagnostic methods worldwide are crucial.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy