  • Asplund, Maria, 1978-, et al. (författare)
  • Composite biomolecule/PEDOT materials for neural electrodes
  • 2008
  • Ingår i: Biointerphases. - NY : American Institute of Physics. - 1559-4106 .- 1934-8630. ; 3:3, s. 83-93
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrodes intended for neural communication must be designed to meet boththe electrochemical and biological requirements essential for long term functionality. Metallic electrode materials have been found inadequate to meet theserequirements and therefore conducting polymers for neural electrodes have emergedas a field of interest. One clear advantage with polymerelectrodes is the possibility to tailor the material to haveoptimal biomechanical and chemical properties for certain applications. To identifyand evaluate new materials for neural communication electrodes, three chargedbiomolecules, fibrinogen, hyaluronic acid (HA), and heparin are used ascounterions in the electrochemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT). The resultingmaterial is evaluated electrochemically and the amount of exposed biomoleculeon the surface is quantified. PEDOT:biomolecule surfaces are also studiedwith static contact angle measurements as well as scanning electronmicroscopy and compared to surfaces of PEDOT electrochemically deposited withsurfactant counterion polystyrene sulphonate (PSS). Electrochemical measurements show that PEDOT:heparinand PEDOT:HA, both have the electrochemical properties required for neuralelectrodes, and PEDOT:heparin also compares well to PEDOT:PSS. PEDOT:fibrinogen isfound less suitable as neural electrode material.
  •  
2.
  • Asplund, Maria, et al. (författare)
  • Construction of wire electrodesand 3D woven logicas a potential technology forneuroprosthetic implants
  • 2008
  • Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294 .- 1558-2531.
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • New strategies to improve neuron coupling to neuroelectronic implants are needed. In particular, tomaintain functional coupling between implant and neurons, foreign body response like encapsulation must meminimized. Apart from modifying materials to mitigate encapsulation it has been shown that with extremely thinstructures, encapsulation will be less pronounced. We here utilize wire electrochemical transistors (WECTs) usingconducting polymer coated fibers. Monofilaments down to 10 μm can be successfully coated and weaved intocomplex networks with built in logic functions, so called textile logic. Such systems can control signal patterns at alarge number of electrode terminals from a few addressing fibres. Not only is fibre size in the range where lessencapsulation is expected but textiles are known to make successful implants because of their soft and flexiblemechanical properties. Further, textile fabrication provides versatility and even three dimensional networks arepossible. Three possible architectures for neuroelectronic systems are discussed. WECTs are sensitive to dehydrationand materials for better durability or improved encapsulation is needed for stable performance in biologicalenvironments.
  •  
3.
  • Asplund, M, et al. (författare)
  • Toxicity evaluation of PEDOT/biomolecular composites intended for neural communication electrodes
  • 2009
  • Ingår i: BIOMEDICAL MATERIALS. - : IOP Publishing. - 1748-6041 .- 1748-605X. ; 4:4, s. 045009-
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrodes coated with the conducting polymer poly(3,4-ethylene dioxythiophene) (PEDOT) possess attractive electrochemical properties for stimulation or recording in the nervous system. Biomolecules, added as counter ions in electropolymerization, could further improve the biomaterial properties, eliminating the need for surfactant counter ions in the process. Such PEDOT/biomolecular composites, using heparin or hyaluronic acid, have previously been investigated electrochemically. In the present study, their biocompatibility is evaluated. An agarose overlay assay using L929 fibroblasts, and elution and direct contact tests on human neuroblastoma SH-SY5Y cells are applied to investigate cytotoxicity in vitro. PEDOT: heparin was further evaluated in vivo through polymer-coated implants in rodent cortex. No cytotoxic response was seen to any of the PEDOT materials tested. The examination of cortical tissue exposed to polymer-coated implants showed extensive glial scarring irrespective of implant material (Pt:polymer or Pt). However, quantification of immunological response, through distance measurements from implant site to closest neuron and counting of ED1+ cell density around implant, was comparable to those of platinum controls. These results indicate that PEDOT: heparin surfaces were non-cytotoxic and show no marked difference in immunological response in cortical tissue compared to pure platinum controls.
  •  
4.
  • Thaning, Elin M., et al. (författare)
  • Stability of Poly(3,4-ethylene dioxythiophene) Materials Intended for Implants
  • 2010
  • Ingår i: Journal of Biomedical Materials Research - Part B Applied Biomaterials. - : Wiley. - 1552-4973 .- 1552-4981. ; 93B:2, s. 407-415
  • Tidskriftsartikel (refereegranskat)abstract
    • This study presents experiments designed to study the stability of the conducting polymer poly(3,4-ethylene dioxythiophene) (PEDOT), under simulated physiological conditions using phosphate-buffered saline (PBS) and hydrogen peroxide (H2O2) (0 01M) at 37 degrees C over a 5- to 6-week period Voltage pulsing in PBS was used as an additional test environment The influence of switching the counter ion used in electropolymerization from polystyrene sulphonate (PSS) to heparin was investigated Absorbance spectroscopy and cyclic voltammetry were used to evaluate the material properties Most of the samples in H2O2 lost both electroactivity and optical absorbance within the study period, but PEDOT.PSS was found slightly more stable than PEDOT heparin. Polymers were relatively stable in PBS throughout the study period, with around 80% of electroactivity remaining after 5 weeks, disregarding delamination, which was a significant problem especially for polymer on indium tin oxide substrates Voltage pulsing in PBS did not increase degradation. The counter ion influenced the time course of degradation in Oxidizing agents.
  •  