SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Holstensson Maria) ;lar1:(kth)"

Sökning: WFRF:(Holstensson Maria) > Kungliga Tekniska Högskolan

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Holstensson, Maria, et al. (författare)
  • Comparison of acquisition protocols for ventilation/perfusion SPECT - a Monte Carlo study
  • 2019
  • Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 64:23
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the most commonly used imaging techniques for diagnosing pulmonary embolism (PE) is ventilation/perfusion (V/P) scintigraphy. The aim of this study was to evaluate the performance of the currently used imaging protocols for V/P single photon emission computed tomography (V/P SPECT) at two nuclear medicine department sites and to investigate the effect of altering important protocol parameters. 
 
 The Monte Carlo technique was used to simulate 4D digital phantoms with perfusion defects. Six imaging protocols were included in the study and a total of 72 digital patients were simulated. Six dually trained radiologists/nuclear medicine physicians reviewed the images and reported all perfusion mismatch findings. The radiologists also visually graded the image quality. 
 
 No statistically significant differences in diagnostic performance were found between the studied protocols, but visual grading analysis pointed out one protocol as significantly superior to four of the other protocols. Considering the study results, we have decided to harmonize our clinical protocols for imaging patients with suspected PE. The administered Technegas and macro aggregated albumin activities have been altered, a low energy all purpose collimator is used instead of a low energy high resolution collimator and the acquisition times have been lowered.
  •  
2.
  • Nilsson, Ted, et al. (författare)
  • Acquisition Duration Optimization Using Visual Grading Regression in [68Ga]FAPI-46 PET Imaging of Oncologic Patients
  • 2024
  • Ingår i: Journal of Nuclear Medicine Technology. - : NA. - 0091-4916 .- 1535-5675. ; 52:3, s. 221-228
  • Tidskriftsartikel (refereegranskat)abstract
    • Fibroblast activation protein is a promising target for oncologic molecular imaging with radiolabeled fibroblast activation protein inhibitors (FAPI) in a large variety of cancers. However, there are yet no published recommendations on how to set up an optimal imaging protocol for FAPI PET/CT. It is important to optimize the acquisition duration and strive toward an acquisition that is sufficiently short while simultaneously providing sufficient image quality to ensure a reliable diagnosis. The aim of this study was to evaluate the feasibility of reducing the acquisition duration of [68Ga]FAPI-46 imaging while maintaining satisfactory image quality, with certainty that the radiologist's ability to make a clinical diagnosis would not be affected. Methods: [68Ga]FAPI-46 PET/CT imaging was performed on 10 patients scheduled for surgical resection of suspected pancreatic cancer, 60 min after administration of 3.6 ± 0.2 MBq/kg. The acquisition time was 4 min/bed position, and the raw PET data were statistically truncated and reconstructed to represent images with an acquisition duration of 1, 2, and 3 min/bed position, additional to the reference images of 4 min/bed position. Four image quality criteria that focused on the ability to distinguish specific anatomic details, as well as perceived image noise and overall image quality, were scored on a 4-point Likert scale and analyzed with mixed-effects ordinal logistic regression. Results: A trend toward increasing image quality scores with increasing acquisition duration was observed for all criteria. For the overall image quality, there was no significant difference between 3 and 4 min/bed position, whereas 1 and 2 min/bed position were rated significantly (P < 0.05) lower than 4 min/bed position. For the other criteria, all images with a reduced acquisition duration were rated significantly inferior to images obtained at 4 min/bed position. Conclusion: The acquisition duration can be reduced from 4 to 3 min/bed position while maintaining satisfactory image quality. Reducing the acquisition duration to 2 min/bed position or lower is not recommended since it results in inferior-quality images so noisy that clinical interpretation is significantly disrupted.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy