  • Fan, Peng, et al. (författare)
  • Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
  • 2015
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 42:12, s. 6895-6911
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c).
  •  
2.
  • Holstensson, Maria, et al. (författare)
  • Optimization of energy-window settings for scatter correction in quantitative In-111 imaging: Comparison of measurements and Monte Carlo simulations
  • 2007
  • Ingår i: Cancer Biotherapy & Radiopharmaceuticals. - : Mary Ann Liebert Inc. - 1557-8852 .- 1084-9785. ; 22:1, s. 136-142
  • Tidskriftsartikel (refereegranskat)abstract
    • Activity quantification in nuclear medicine imaging is highly desirable, particularly for dosimetry and biodistribution studies of radiopharmaceuticals. Quantitative In-111 imaging is increasingly important with the current interest in therapy using Y-90 radiolabeled antibodies. One of the major problems in quantification is scatter in the images, which leads to degradation of image quality. The aim of this study was to optimize the energy-window settings for quantitative In-111 imaging with a camera that enabled acquisition in three energy windows. Experimental measurements and Monte Carlo simulations, using the SI-MIND code, were conducted to investigate parameters such as sensitivity, image contrast, and image resolution. Estimated scatter-to-total ratios and distributions, as obtained by the different window settings, were compared with corresponding simulations. Results showed positive agreement between experimental measurements and results from simulations, both quantitatively and qualitatively. We conclude that of the investigated methods, the optimal energy-window setting was two windows centered at 171 and 245 keV, together with a broad scatter window located between the photopeaks.
  •  