1. |
- Birch, J., et al.
(författare)
-
Multi-Grid boron-10 detector for time-of-flight spectrometers in neutron scattering science
- 2015
-
Ingår i: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
-
Konferensbidrag (refereegranskat)abstract
- The Multi-Grid (MG) detector has been introduced at ILL and developed by a collaboration between ILL, ESS and Linkoping University. This detector design addresses the severely decreased availability of He3, in particular for neutron scattering instruments with large-area detectors, such as time-of-flight neutron spectrometers at ESS and other facilities. The MG detector is based on thin converter films of boron-10 carbide arranged in layers orthogonal to the incoming neutrons. The design of the detector provides position resolution, efficiency competitive with He3 and a strong gamma rejection capability. This paper presents the MG large-area (2.4m2) demonstrator and the progress made in order to meet the needs of production of B4C-coated layers, mechanical parts and assembly on a scale similar to that of the final detectors for ESS. A particular effort was made to produce aluminium detector parts with a low alpha background, successfully reducing the background rate to acceptable levels. Following the IN5 demonstrator, a compact prototype has been designed in order to finalise the electronic readout to be used at the ESS instruments equipped with the MG.
|
|
2. |
|
|
3. |
|
|
4. |
- Pfeiffer, D., et al.
(författare)
-
First measurements with new high-resolution gadolinium-GEM neutron detectors
- 2016
-
Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 11
-
Tidskriftsartikel (refereegranskat)abstract
- European Spallation Source instruments like the macromolecular diffractometer (NMX) require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The mu TPC analysis, proven to improve the spatial resolution in the case of B-10 converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 angstrom and a position resolution better than 250 mu m.
|
|