1.
  • Matura, Mihaly, 1964, et al. (författare)
  • Not only oxidized R-(+)- but also S-(-)-limonene is a common cause of contact allergy in dermatitis patients in Europe.
  • 2006
  • Ingår i: Contact dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 55:5, s. 274-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Limonene, one of the most often used fragrance terpenes in any kind of scented products, is prone to air-oxidation. The oxidation products formed have a considerable sensitizing potential. In previous patch test studies on consecutively tested dermatitis patients, oxidized R-limonene has been proven to be a good and frequent indicator of fragrance-related contact allergy. The current study extends these investigations to 6 European clinics of dermatology, where the oxidation mixture of both enantiomers of limonene (R and S) have been tested in 2411 dermatitis patients. Altogether, 63 out of 2411 patients tested (2.6%) reacted to 1 or both the oxidized limonene preparations. Only 2.3% reacted to the oxidized R-limonene and 2.0% to the oxidized S-limonene. In 57% of the cases, simultaneous reactions were observed to both oxidation mixtures. Concomitant reactions to the fragrance mix, colophonium, Myroxylon pereirae, and fragrance-related contact allergy were common in patients reacting to 1 or both the oxidized limonene enantiomers. Our study provides clinical evidence for the importance of oxidation products of limonene in contact allergy. It seems advisable to screen consecutive dermatitis patients with oxidized limonene 3% petrolatum, although this patch test material is not yet commercially available.
  •  
2.
  • Bennike, Niels H., et al. (författare)
  • Allergic contact dermatitis caused by hydroperoxides of limonene and dose-response relationship-A repeated open application test (ROAT) study
  • 2019
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 80:4, s. 208-216
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Contact allergy to oxidized limonene, with hydroperoxides of limonene (Lim-OOHs) as the main allergens, is common. However, high proportions of weak positive and doubtful patch test reactions have been reported. Objectives: To determine the clinical relevance, elicitation threshold and dose-response relationship of Lim-OOHs in individuals with a positive or doubtful patch test reaction to standard Lim-OOHs 0.3% pet. Methods: A multicentre 3-week double-blind vehicle-controlled repeated open application test (ROAT) study with a simulated fine fragrance containing Lim-OOHs at 1260, 420 and 140 ppm, equal to a dose/area per application of Lim-OOHs of 3.0, 0.99 and 0.33 mu g/cm(2), was performed. Results: Among 11 subjects allergic to Lim-OOHs, 11 (100%), 7 (64%), and 3 (27%), respectively, reacted to the applied doses. No reactions were seen in 17 healthy controls exposed to the highest dose. This difference in reactivity was statistically significant (P < 0.0001). Among 13 subjects with doubtful patch test reactions to Lim-OOHs, two (15%) had positive ROAT reactions to the highest Lim-OOH dose applied (P = 0.36 as compared with controls). Conclusions: Contact allergy to Lim-OOHs is of clinical relevance in patients with positive patch test reactions. A doubtful patch test reaction to Lim-OOHs 0.3% pet. can be of clinical relevance.
  •  
3.
  • Hamann, Dathan, et al. (författare)
  • Jewellery : alloy composition and release of nickel, cobalt and lead assessed with the EU synthetic sweat method
  • 2015
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 73:4, s. 231-238
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. Several studies have shown nickel and cobalt release from jewellery by using spot tests, but the metal composition of jewellery is largely unknown. Objectives. To evaluate the metal composition of a large worldwide sample of mainly inexpensive jewellery items, and investigate the release of nickel, cobalt and lead from a subsample by using EN 1811: 1998-required methods. Methods. A total of 956 metallic jewellery components were examined with X-ray fluorescence spectroscopy. A subsample of 96 jewellery items purchased in the United States were investigated for nickel, cobalt and lead release by the use of artificial sweat immersion and plasma optical emission spectroscopy. Results. Eighteen elements were detected. The 10 most frequently occurring were, in order of frequency, copper, iron, zinc, nickel, silver, chromium, tin, manganese, lead, and cobalt. Release of nickelwas noted from 79 of the 96 US samples (0.01-98 mu g/cm(2)/week), release of cobalt from 35 samples (0.02-0.5 mu g/cm(2)/week), and release of lead from 37 samples (0.03-2718 mu g/cm(2)/week). Conclusions. We present here a comprehensive list of the most frequently encountered metals in jewellery and fashion accessories. Different allergenic and non-allergenic metals are utilized. We also report the frequent release of nickel, cobalt and lead from these objects, despite legislative restrictions.
  •  
4.
  • Jakobsen, Stig S., et al. (författare)
  • Failure of total hip implants : metals and metal release in 52 cases
  • 2014
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 71:6, s. 319-325
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThe pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. ObjectivesTo assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene total hip replacements. Materials/methodsImplant components from 52 revision cases were evaluated with spot tests for free nickel, cobalt, and chromium (VI) ions. Implant composition was determined with X-ray fluorescence spectroscopy, and information on the reason for revision and complications in relation to surgery was collected from the medical charts when possible (72%). For 10 implants, corrosion was further characterized with scanning electron microscopy. ResultsWe detected cobalt release from three of 38 removed femoral heads and from one of 24 femoral stems. Nickel release was detected from one of 24 femoral stems. No chromium(VI) release was detected. ConclusionsWe found that cobalt and nickel were released from some failed total hip arthroplasties, and corrosion was frequently observed. Metal ions and particles corroded from metal-on-polyethylene may play a role in the complex aetiopathology of implant failure.
  •  