SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Johansson A. G. M.) ;srt2:(2015-2019);lar1:(ri)"

Sökning: WFRF:(Johansson A. G. M.) > (2015-2019) > RISE

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Merlone, A., et al. (författare)
  • The MeteoMet project - metrology for meteorology: challenges and results
  • 2015
  • Ingår i: Meteorological Applications. - : Wiley. - 1350-4827 .- 1469-8080. ; 22, s. 820-829
  • Tidskriftsartikel (refereegranskat)abstract
    • The study describes significant outcomes of the Metrology for Meteorology' project, MeteoMet, which is an attempt to bridge the meteorological and metrological communities. The concept of traceability, an idea used in both fields but with a subtle difference in meaning, is at the heart of the project. For meteorology, a traceable measurement is the one that can be traced back to a particular instrument, time and location. From a metrological perspective, traceability further implies that the measurement can be traced back to a primary realization of the quantity being measured in terms of the base units of the International System of Units, the SI. These two perspectives reflect long-standing differences in culture and practice and this project - and this study - represents only the first step towards better communication between the two communities. The 3 year MeteoMet project was funded by the European Metrology Research Program (EMRP) and involved 18 European National Metrological Institutes, 3 universities and 35 collaborating stakeholders including national meteorology organizations, research institutes, universities, associations and instrument companies. The project brought a metrological perspective to several long-standing measurement problems in meteorology and climatology, varying from conventional ground-based measurements to those made in the upper atmosphere. It included development and testing of novel instrumentation as well as improved calibration procedures and facilities, instrument intercomparison under realistic conditions and best practice dissemination. Additionally, the validation of historical temperature data series with respect to measurement uncertainties and a methodology for recalculation of the values were included.
  •  
2.
  • Wagner, J., et al. (författare)
  • First 230? : GHz VLBI fringes on 3C 279 using the APEX Telescope (Research Note)
  • 2015
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 581
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims. We report about a 230? GHz very long baseline interferometry (VLBI) fringe finder observation of blazar 3C 279 with the APEX telescope in Chile, the phased submillimeter array (SMA), and the SMT of the Arizona Radio Observatory (ARO). Methods. We installed VLBI equipment and measured the APEX station position to 1? cm accuracy (1σ). We then observed 3C 279 on 2012 May 7 in a 5? h 230? GHz VLBI track with baseline lengths of 2800? Mλ to 7200? Mλ and a finest fringe spacing of 28.6? μas. Results. Fringes were detected on all baselines with signal-to-noise ratios of 12 to 55 in 420? s. The correlated flux density on the longest baseline was ∼0.3? Jy beam-1, out of a total flux density of 19.8? Jy. Visibility data suggest an emission region ≤ 38? μas in size, and at least two components, possibly polarized. We find a lower limit of the brightness temperature of the inner jet region of about 1010? K. Lastly, we find an upper limit of 20% on the linear polarization fraction at a fringe spacing of ∼ 38? μas. Conclusions. With APEX the angular resolution of 230? GHz VLBI improves to 28.6? μas. This allows one to resolve the last-photon ring around the Galactic Center black hole event horizon, expected to be 40? μas in diameter, and probe radio jet launching at unprecedented resolution, down to a few gravitational radii in galaxies like M 87. To probe the structure in the inner parsecs of 3C 279 in detail, follow-up observations with APEX and five other mm-VLBI stations have been conducted (March 2013) and are being analyzed.
  •  
3.
  • Riordan, E, et al. (författare)
  • Design and implementation of a low temperature, inductance based high frequency alternating current susceptometer.
  • 2019
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 90:7
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the implementation of an induction based, low temperature, high frequency ac susceptometer capable of measuring at frequencies up to 3.5 MHz and at temperatures between 2 K and 300 K. Careful balancing of the detection coils and calibration allow a sample magnetic moment resolution of 5 × 10−10 Am2 at 1 MHz. We discuss the design and characterization of the susceptometer and explain the calibration process. We also include some example measurements on the spin ice material CdEr2S4 and iron oxide based nanoparticles to illustrate functionality.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy