SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Jui C) "

Sökning: WFRF:(Jui C)

  • Resultat 1-10 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
4.
  • Ahmed, M., et al. (författare)
  • Search for the lepton-family-number nonconserving decay μ +→e +γ
  • 2002
  • Ingår i: Physical Review D. - : American Physical Society. - 1550-7998 .- 1550-2368. ; 65:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The MEGA experiment, which searched for the muon- and electron-number violating decay μ +→e + γ, is described. The spectrometer system, the calibrations, the data taking procedures, the data analysis, and the sensitivity of the experiment are discussed. The most stringent upper limit on the branching ratio, B(μ + →e + γ)<1.2×10 -11 with 90% confidence, is derived from a likelihood analysis.
  •  
5.
  • Amann, F., et al. (författare)
  • A search for murarregamma at the level of 10-13
  • 1991
  • Ingår i: Proceedings of the 25th International Conference on High Energy Physics. - 9810024347 ; , s. 1070-1071
  • Konferensbidrag (refereegranskat)abstract
    • The MEGA experiment, which is a search for the decay murarregamma with a branching ratio sensitivity of about 10-13, employs highly modular, fast detectors, state-of-the-art electronics, and a staged trigger with on-line filters. The detectors are contained in a 1.5-T solenoidal field produced by a superconducting magnet. Positrons are confined to the central region and are measured by a set of thin MWPCs. Photons are measured by one of four layers of pair spectrometers in the outer region. Most aspects of the design have been validated in engineering runs; data taking will begin in 1990 with much of the electron arm and one pair spectrometer layer installed.
  •  
6.
  •  
7.
  • Szymanski, J. J., et al. (författare)
  • MEGA : A search for the decay mu –> e gamma
  • 1994
  • Ingår i: Intersections between particle and nuclear physics. Proceedings, 5th Conference, St. Petersburg, USA, May 31-June 6, 1994. ; , s. 789-792
  • Konferensbidrag (refereegranskat)
  •  
8.
  •  
9.
  • Cooper, M. D., et al. (författare)
  • Construction and performance of MEGA's low-mass, high-rate cylindrical MWPCs
  • 1998
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 417:1, s. 24-49
  • Tidskriftsartikel (refereegranskat)abstract
    • A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for the lepton family number violating decay μ → eγ. To extend the present branching ratio limit by over an order of magnitude, these MWPCs were operated in high particle fluxes. They showed minimal effects of aging, and evidenced spatial and energy resolutions for the orbiting positrons from muon decay which were consistent with our design parameters. The unique features of these chambers, their assembly into the MEGA positron spectrometer, and their performance during the experiment are described in this paper.
  •  
10.
  • Armijo, V., et al. (författare)
  • A fast MWPC with cathode strips and utilizing CF4-isobutane
  • 1991
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 303:2, s. 298-308
  • Tidskriftsartikel (refereegranskat)abstract
    • A planar wire chamber has been developed at LAMPF as a prototype for wire chambers of cylindrical configuration for electron detection in the MEGA experiment. Results form tests with the planar chamber have been used to set the geometrical parameters and predict the performance characteristics of the cylindrical chambers. The behavior of the planar chamber with CF4-isobutane gas demonstrates that 15 μm wire of 1 mm pitch is practical, that lifetimes greater than 0.045 C/cm are achievable and that gate widths of 25 ns are possible. © 1991.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy