SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kanai Y) ;pers:(Klamra Wlodzimierz)"

Sökning: WFRF:(Kanai Y) > Klamra Wlodzimierz

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson, V., et al. (författare)
  • Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO)
  • 2005
  • Ingår i: Proceedings of the 22nd Texas Symposium on Relativistic Astrophysics at Stanford. ; , s. 736-743
  • Konferensbidrag (refereegranskat)abstract
    • We are developing a new balloon-borne instrument (PoGO), to measure polarization of soft gamma rays (30-200 keV) using asymmetry in azimuth angle distribution of Compton scattering. PoGO is designed to detect 10 % polarization in 100mCrab sources in a 6-8 hour observation and bring a new dimension to studies on gamma ray emission/transportation mechanism in pulsars, AGNs, black hole binaries, and neutron star surface. The concept is an adaptation to polarization measurements of well-type phoswich counter consisting of a fast plastic scintillator (the detection part), a slow plastic scintillator (the active collimator) and a BGO scintillator (the bottom anti-counter). PoGO consists of close-packed array of 217 hexagonal well-type phoswich counters and has a narrow field-of-view (~ 5 deg2) to reduce possible source confusion. A prototype instrument has been tested in the polarized soft gamma-ray beams at Advanced Photon Source (ANL) and at Photon Factory (KEK). On the results, the polarization dependence of EGS4 has been validated and that of Geant4 has been corrected.
  •  
2.
  • Takahashi, H., et al. (författare)
  • A thermal-neutron detector with a phoswich system of LiCaAlF6 and BGO crystal scintillators onboard PoGOLite
  • 2010
  • Ingår i: 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010. ; , s. 32-37
  • Konferensbidrag (refereegranskat)abstract
    • To measure the flux of atmospheric neutrons and study the neutron contribution to the background of the main detector of the PoGOLite (Polarized Gamma-ray Observer) balloon-borne experiment, a thermal-neutron detector with a phoswich system of LiCaAlF6 (Eu) and BGO crystal scintillators is developed. The performance to separate thermal-neutron events from those of gamma-rays and charged particles is validated with 252Cf on ground. The detector is attached to the PoGOLite instrument and is launched in 2011 from the Esrange facility in the North of Sweden. Although the emission wavelength of the LiCaAlF6 (Ce) is 300 nm and overlaps with the absorption wavelength of the BGO, the phoswich capability of the LiCaAlF6 (Ce) with the BGO is also confirmed with installing a waveform shifter.
  •  
3.
  • Arimoto, M., et al. (författare)
  • Performance assessment study of the balloon-borne astronomical soft gamma-ray polarimeter PoGOLite
  • 2007
  • Ingår i: Physica. E, Low-Dimensional systems and nanostructures. - : Elsevier BV. - 1386-9477 .- 1873-1759. ; 40:2, s. 438-441
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements of polarization play a crucial role in the understanding of the dominant emission mechanism of astronomical sources. Polarized Gamma-ray Observer-Light version (PoGOLite) is a balloon-borne astronomical soft gamma-ray polarimeter at the 25-80 keV band. The PoGOLite detector consists of a hexagonal close-packed array of 217 Phoswich detector cells (PDCs) and side anti-coincidence shields (SASs) made of BGO crystals surrounding PDCs. Each PDC consists of a slow hollow scintillator, a fast scintillator and a BGO crystal that connects to a photomultiplier tube at the end. To examine the PoGOLite's capability and estimate the performance, we conducted experiments with the PDC using radioisotope 241Am. In addition, we compared this result with performance expected by Monte Carlo simulation with Geant4. As a result, we found that the actual PDC has the capability to detect a 100 m Crab source until 80 keV.
  •  
4.
  • Kanai, Y., et al. (författare)
  • Beam test of a prototype phoswich detector assembly for the PoGOLite astronomical soft gamma-ray polarimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 570:1, s. 61-71
  • Tidskriftsartikel (refereegranskat)abstract
    • We report about the beam test on a prototype of the balloon-based astronomical soft gamma-ray polarimeter, PoGOLite (Polarized Gamma-ray Observer-Light Version) conducted at KEK Photon Factory, a synchrotron radiation facility in Japan. The synchrotron beam was set at 30, 50, and 70 keV and its polarization was monitored by a calibrated polarimeter. The goal of the experiment was to validate the flight design of the polarimeter. PoGOLite is designed to measure polarization by detecting a Compton scattering and the subsequent photo-absorption in an array of 217 well-type phoswich detector cells (PDCs). The test setup included a first flight model PDC and a front-end electronics to select and reconstruct valid Compton scattering events. The experiment has verified that the flight PDC can detect recoil electrons and select valid Compton scattering events down to 30 keV from background. The measure azimuthal modulations (34.4%, 35.8% and 37.2% at 30, 50, and 70 keV, respectively) agreed within 10% (relative) with the predictions by Geant4 implemented with dependence on the initial and final photon polarizations.
  •  
5.
  • Kiss, Mózsi, et al. (författare)
  • The PoGOLite balloon-borne soft gamma-ray polarimeter
  • 2008
  • Ingår i: COOL DISCS, HOT FLOWS. - : AIP. ; , s. 225-232
  • Konferensbidrag (refereegranskat)abstract
    • Linearly polarized radiation in the hard X-ray/soft gamma-ray band is expected from a large variety of astronomical sources. We discuss the importance of polarimetric studies for several classes of sources - pulsars, accreting black holes. magnetic neutron stars and jets from active galaxies - and then describe PoGOLite, a balloon-borne instrument which is currently under construction and will be able to measure the polarization of electromagnetic radiation from such extra-solar objects in the energy range 25-80 keV.
  •  
6.
  • Mizuno, T., et al. (författare)
  • A Monte Carlo method for calculating the energy response of plastic scintillators to polarized photons below 100 keV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 600:3, s. 609-617
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy response of plastic scintillators (Eljen Technology EJ-204) to polarized soft gamma-ray photons below 100 keV has been studied, primarily for the balloon-borne polarimeter, PoGOLite. The response calculation includes quenching effects due to low-energy recoil electrons and the position dependence of the light collection efficiency in a 20 cm long scintillator rod. The broadening of the pulse-height spectrum, presumably caused by light transportation processes inside the scintillator, as well as the generation and multiplication of photoelectrons in the photomultiplier tube, were studied experimentally and have also been taken into account. A Monte Carlo simulation based on the Geant4 toolkit was used to model photon interactions in the scintillators. When using the polarized Compton/Rayleigh scattering processes previously corrected by the authors, scintillator spectra and angular distributions of scattered polarized photons could clearly be reproduced, in agreement with the results obtained at a synchrotron beam test conducted at the KEK Photon Factory. Our simulation successfully reproduces the modulation factor, defined as the ratio of the amplitude to the mean of the distribution of the azimuthal scattering angles, within similar to 5% (relative). Although primarily developed for the PoGOLite mission, the method presented here is also relevant for other missions aiming to measure polarization from astronomical objects using plastic scintillator scatterers. 
  •  
7.
  • Takahashi, H., et al. (författare)
  • Beam test results of the polarized gamma-ray observer, PoGOLite
  • 2008
  • Ingår i: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. - 9781424427147 ; , s. 732-736
  • Konferensbidrag (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy range 25 #x2013;80 keV. During a beam test at KEK-PF in February 2008, 20 detector units were assembled, and a 50 keV X-ray beam with a polarization degree of #x223C;90% was irradiated at the center unit. Signals from all 20 units were fed into flightversion electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 PDCs, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be #x223C;34%. These results confirmed the capabilities of both detector and data-acquisition system for a pathfinder flight planned in 2010.
  •  
8.
  • Takahashi, H., et al. (författare)
  • The Polarized Gamma-Ray Observer, PoGOLite
  • 2010
  • Ingår i: Transactions of the Japanese Society for Artificial Intelligence, Aerospace Technology Japan. - 1346-0714 .- 1346-0714. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy-range 25–80 keV. During a beam test at KEK-PF in 2008, 19 detector units and one anti-coincidence detector were assembled, and a 50 keV X-ray beam with a polarization degree of ∼90% was irradiated at the center unit. Signals from all 20 units were fed into flight-version electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 detectors, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be ∼34%. These results confirmed the capabilities of the data-acquisition system for a “pathfinder” flight planned in 2010.
  •  
9.
  • Axelsson, Magnus, et al. (författare)
  • Measuring energy dependent polarization in soft gamma-rays using compton scattering in PoGOLite
  • 2007
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 28:3, s. 327-337
  • Tidskriftsartikel (refereegranskat)abstract
    • Linear polarization in X-and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization measurements have been made, and then only mono-energetic detections, whilst several objects are assumed to have energy dependent polarization signatures. In this paper, we investigate whether detection of energy dependent polarization from cosmic sources is possible using the Compton technique, in particular with the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6 and 35 h were simulated, corresponding to a standard and a long duration flight, respectively. Both smooth and sharp energy variations of the polarization are investigated and compared to constant polarization signals using chi-square statistics. We can reject constant polarization, with energy, for the Cygnus X-1 spectrum (in the hard state), if the reflected component is assumed to be completely polarized, whereas the distinction cannot be made for weaker polarization. For the accreting pulsar, constant polarization can be rejected in the case of polarization in a narrow energy band with at least 50% polarization, and similarly for a negative step distribution from 30% to 0% polarization.
  •  
10.
  • Mizuno, T., et al. (författare)
  • High sensitivity balloon-borne hard X-ray/soft Gamma-Ray Polarimeter PoGOLite
  • 2007
  • Ingår i: Nuclear Science Symposium Conference Record, 2007. NSS ’07. IEEE. - : IEEE. - 9781424409228 ; , s. 2538-2544
  • Konferensbidrag (refereegranskat)abstract
    • The Polarized Gamma-ray Observer - Lightweight version (PoGOLite) is a new balloon experiment capable of detecting 10% polarization from a 200 mCrab source in the 25-80 keV energy range in a single 6-hour flight for the first time. Polarization measurements of hard X-rays and soft gamma-rays are expected to provide a powerful probe into high-energy emission mechanisms as well as source geometries. PoGOLite uses Compton scattering and photo-absorption to measure polarization in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators. The adoption of a well-type phoswich counter concept and a thick polyethylene neutron shield provides a narrow field-of-view (1.25 msr), a large effective area ( gt; 250 cm2 at 40-50 keV), a high modulation factor (more than 25%) and the low background ( 100 mCrab) required to conduct high-sensitivity polarization measurements. Through tests in laboratories and accelerator facilities of a scaled-down prototype with the front-end electronics of flight design and an extensive study by Monte Carlo simulation, we have demonstrated high instrument performance. PoGOLite will be ready for a first engineering flight in 2009 and a science flight in 2010, during which polarization signals from the Crab Nebula/pulsar, Cygnus X-1 and other objects will be observed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy