SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kjellström Erik) ;pers:(Laurell Thomas)"

Sökning: WFRF:(Kjellström Erik) > Laurell Thomas

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Miliotis, Tasso, et al. (författare)
  • Protein identification platform utilizing micro dispensing technology interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry
  • 2000
  • Ingår i: Journal of Chromatography A. - 0021-9673. ; 886:1-2, s. 99-110
  • Tidskriftsartikel (refereegranskat)abstract
    • An integrated protein microcharacterization/identification platform has been developed. The system has been designed to allow a high flexibility in order to tackle challenging analytical problems. The platform comprises a cooled microautosampler, an integrated system for microcolumn HPLC, and a capillary reversed-phase column that is interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) system via a low internal volume flow-through microdispenser. The chromatographic separation is continuously transferred onto a MALDI target plate as discrete spots as the dispenser ejects bursts of droplets of the column effluent in a precise array pattern. A refrigerated microfraction collector was coupled to the outlet of the flow-through microdispenser enabling enrichment and re-analysis of interesting fractions. The use of target plates pre-coated with matrix simplified and increased the robustness of the system. By including a separation step prior to the MALDI-TOF-MS analysis and hereby minimizing suppression effects allowed us to obtain higher sequence coverage of proteins compared to conventional MALDI sample preparation methodology. Additionally, synthetic peptides corresponding to autophosphorylated forms of the tryptic fragment 485-496 (ALGADDSYYTAR) of tyrosine kinase ZAP-70 were identified at sensitivities reaching 150 amol. Copyright (C) 2000 Elsevier Science B.V.
  •  
2.
  • Miliotis, Tasso, et al. (författare)
  • Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format.
  • 2002
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 1097-0231 .- 0951-4198. ; 16:2, s. 117-126
  • Tidskriftsartikel (refereegranskat)abstract
    • The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Nilsson, Johan (2)
Marko-Varga, György (2)
Kjellström, Sven (2)
Miliotis, Tasso (2)
Edholm, Lars Erik (2)
visa fler...
Önnerfjord, Patrik (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (2)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy