  • Danad, Ibrahim, et al. (författare)
  • Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [O-15]H2O PET Imaging
  • 2014
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 64:14, s. 1464-1475
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD. OBJECTIVES The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [O-15]H2O positron emission tomography (PET). METHODS A total of 330 patients underwent both quantitative [O-15]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve <= 0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive. RESULTS Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 +/- 0.25 and 0.92 +/- 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 +/- 1.04 ml/min/g and 1.73 +/- 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET. CONCLUSIONS Quantitative MBF measurements with the use of [O-15]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.
  •  
5.
  • Grönman, Maria, et al. (författare)
  • Assessment of myocardial viability with [15O]water PET : A validation study in experimental myocardial infarction
  • 2021
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Nature. - 1071-3581 .- 1532-6551. ; 28:4, s. 1271-1280
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Assessment of myocardial viability is often needed in patients with chest pain and reduced ejection fraction. We evaluated the performance of reduced resting MBF, perfusable tissue fraction (PTF), and perfusable tissue index (PTI) in the assessment of myocardial viability in a pig model of myocardial infarction (MI).METHODS AND RESULTS: Pigs underwent resting [15O]water PET perfusion study 12 weeks after surgical (n = 16) or 2 weeks after catheter-based (n = 4) occlusion of the proximal left anterior descending coronary artery. MBF, PTF, and PTI were compared with volume fraction of MI in matched segments as assessed by triphenyl tetrazolium chloride staining of LV slices. MBF and PTF were lower in infarcted than non-infarcted segments. Segmental analysis of MBF showed similar area under the curve (AUC) of 0.85, 0.86, and 0.90 with relative MBF, PTF, and PTI for the detection of viable myocardium defined as infarct volume fraction of < 75%. Cut-off values of relative MBF of ≥ 67% and PTF of ≥ 66% resulted in accuracies of 90% and 81%, respectively.CONCLUSIONS: Our results indicate that resting MBF, PTF, and PTI based on [15O]water PET perfusion imaging are useful for the assessment of myocardial viability.
  •  
6.
  • Hoek, Roel, et al. (författare)
  • Determining Hemodynamically Significant Coronary Artery Disease : Patient-Specific Cutoffs in Quantitative Myocardial Blood Flow Using [15O]H2O PET Imaging
  • 2024
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 65:7, s. 1113-1121
  • Tidskriftsartikel (refereegranskat)abstract
    • Currently, cutoffs of quantitative [15O]H2O PET to detect fractional flow reserve (FFR)-defined coronary artery disease (CAD) were derived from a single cohort that included patients without prior CAD. However, prior CAD, sex, and age can influence myocardial blood flow (MBF). Therefore, the present study determined the influence of prior CAD, sex, and age on optimal cutoffs of hyperemic MBF (hMBF) and coronary flow reserve (CFR) and evaluated whether cutoff optimization enhanced diagnostic performance of quantitative [15O]H2O PET against an FFR reference standard. Methods: Patients with chronic coronary symptoms underwent [15O]H2O PET and invasive coronary angiography with FFR. Optimal cutoffs for patients with and without prior CAD and subpopulations based on sex and age were determined. Results: This multicenter study included 560 patients. Optimal cutoffs were similar for patients with (n = 186) and without prior CAD (hMBF, 2.3 vs. 2.3 mL center dot min-1 center dot g-1; CFR, 2.7 vs. 2.6). Females (n = 190) had higher hMBF cutoffs than males (2.8 vs. 2.3 mL center dot min-1 center dot g-1), whereas CFRs were comparable (2.6 vs. 2.7). However, female sex-specific hMBF cutoff implementation decreased diagnostic accuracy as compared with the cutoff of 2.3 mL center dot min-1 center dot g-1 (72% vs. 82%, P , 0.001). Patients aged more than 70 y (n = 79) had lower hMBF (1.7 mL center dot min-1 center dot g-1) and CFR (2.3) cutoffs than did patients aged 50 y or less, 51-60 y, and 61-70 y (hMBF, 2.3-2.4 mL center dot min-1 center dot g-1; CFR, 2.7). Age-specific cutoffs in patients aged more than 70 y yielded comparable accuracy to the previously established cutoffs (hMBF, 72% vs. 76%, P = 0.664; CFR, 80% vs. 75%, P = 0.289). Conclusion: Patients with and without prior CAD had similar [15O]H2O PET cutoffs for detecting FFR-defined significant CAD. Stratifying patients according to sex and age led to different optimal cutoffs; however, these values did not translate into an increased overall accuracy as compared with previously established thresholds for MBF.
  •  
7.
  • Kero, Tanja, et al. (författare)
  • Quantitative myocardial perfusion response to adenosine and regadenoson in patients with suspected coronary artery disease
  • 2022
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 29:1, s. 24-36
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aim of the present study was to compare the quantitative flow responses of regadenoson against adenosine using cardiac 15O-water PET imaging in patients with suspected or known coronary artery disease (CAD).METHODS: Hyperemic myocardial blood flow (MBF) after adenosine and regadenoson was compared using correlation and Bland-Altman analysis in 21 patients who underwent rest and adenosine 15O-water PET scans followed by rest and regadenoson 15O-water PET scans.RESULTS: Global mean (± SD) MBF values at rest and stress were 0.92 ± 0.27 and 2.68 ± 0.80 mL·g·min for the adenosine study and 0.95 ± 0.29 and 2.76 ± 0.79 mL·g·min for the regadenoson study (P = 0.55 and P = 0.49). The correlations between global and regional adenosine- and regadenoson-based stress MBF were strong (r = 0.80 and r = 0.77). The biases were small for both global and regional MBF comparisons (0.08 and 0.09 mL·min·g), but the limits of agreement were wide for stress MBF.CONCLUSION: The correlation between regadenoson- and adenosine-induced hyperemic MBF was strong but the agreement was only moderate indicating that established cut-off values for 150-water PET should be used cautiously if using regadenoson as vasodilator.
  •  
8.
  •  
9.
  •  
10.
  • Rissanen, Tuomas T., et al. (författare)
  • The bottleneck stent model for chronic myocardial ischemia and heart failure in pigs
  • 2013
  • Ingår i: American Journal of Physiology. Heart and Circulatory Physiology. - : American Physiological Society. - 0363-6135 .- 1522-1539. ; 305:9, s. H1297-H1308
  • Tidskriftsartikel (refereegranskat)abstract
    • A large animal model of chronic myocardial ischemia and heart failure is crucial for the development of novel therapeutic approaches. In this study we developed a novel percutaneous one-and two-vessel model for chronic myocardial ischemia using a stent coated with a polytetrafluoroethylene tube formed in a bottleneck shape. The bottleneck stent was implanted in the proximal left anterior descending (LAD) or proximal circumflex artery (LCX), or in both proximal LCX and mid LAD 1 wk later (2-vessel model), and pigs were followed for 4-5 wk. Ejection fraction (EF), infarct size, collateral growth, and myocardial perfusion were assessed. Pigs were given antiarrhythmic medication to prevent sudden death. The occlusion time of the bottleneck stent and the timing of myocardial infarction could be modulated by the duration of antiplatelet medication. Fractional flow reserve measurements and positron emission tomography imaging showed severe ischemia after bottleneck stenting covering over 50% of the left ventricle in the proximal LAD model. Complete coronary occlusion was necessary for significant collateral growth, which mostly had occurred already during the first wk after the stent occlusion. Dynamic and competitive collateral growth patterns were observed. EF declined from 64 to 41% in the LCX model and to 44% in the LAD model 4 wk after stenting with 12 and 21% infarcted left ventricle in the LCX and LAD models, respectively. The mortality was 32 and 37% in the LCX and LAD models but very (71%) high in the two-vessel disease model. The implantation of a novel bottleneck stent in the proximal LAD or LCX is a novel porcine model of reversible myocardial ischemia (open stent) and ischemic heart failure (occluded stent) and is feasible for the development of new therapeutic approaches.
  •  