SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kraljevic I.) "

Sökning: WFRF:(Kraljevic I.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abele, H., et al. (författare)
  • Particle physics at the European Spallation Source
  • 2023
  • Ingår i: Physics reports. - : Elsevier. - 0370-1573 .- 1873-6270. ; 1023, s. 1-84
  • Forskningsöversikt (refereegranskat)abstract
    • Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world’s brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).
  •  
2.
  • Valassi, E., et al. (författare)
  • High mortality within 90 days of diagnosis in patients with Cushing's syndrome: results from the ERCUSYN registry
  • 2019
  • Ingår i: European Journal of Endocrinology. - : Oxford University Press (OUP). - 0804-4643 .- 1479-683X. ; 181:5, s. 461-472
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Patients with Cushing's syndrome (CS) have increased mortality. The aim of this study was to evaluate the causes and time of death in a large cohort of patients with CS and to establish factors associated with increased mortality. Methods: In this cohort study, we analyzed 1564 patients included in the European Registry on CS (ERCUSYN); 1045 (67%) had pituitary-dependent CS, 385 (25%) adrenal-dependent CS, 89 (5%) had an ectopic source and 45 (3%) other causes. The median (IQR) overall follow-up time in ERCUSYN was 2.7 (1.2-5.5) years. Results: Forty-nine patients had died at the time of the analysis; 23 (47%) with pituitary-dependent CS, 6 (12%) with adrenal-dependent CS, 18 (37%) with ectopic CS and two (4%) with CS due to other causes. Of 42 patients whose cause of death was known, 15 (36%) died due to progression of the underlying disease, 13 (31%) due to infections, 7 (17%) due to cardiovascular or cerebrovascular disease and 2 due to pulmonary embolism. The commonest cause of death in patients with pituitary-dependent CS and adrenal-dependent CS were infectious diseases (n = 8) and progression of the underlying tumor (n = 10) in patients with ectopic CS. Patients who had died were older and more often males, and had more frequently muscle weakness, diabetes mellitus and ectopic CS, compared to survivors. Of 49 deceased patients, 22 (45%) died within 90 days from start of treatment and 5 (10%) before any treatment was given. The commonest cause of deaths in these 27 patients were infections (n = 10; 37%). In a regression analysis, age, ectopic CS and active disease were independently associated with overall death before and within 90 days from the start of treatment. Conclusion: Mortality rate was highest in patients with ectopic CS. Infectious diseases the commonest cause of death soon after diagnosis, emphasizing the need for careful vigilance at that time, especially in patients presenting with concomitant diabetes mellitus.
  •  
3.
  • Burgman, A., et al. (författare)
  • The ESSnuSB Design Study: Overview and Future Prospects
  • 2023
  • Ingår i: Universe. - : MDPI. - 2218-1997. ; 9:8
  • Forskningsöversikt (refereegranskat)abstract
    • ESSnuSB is a design study for an experiment to measure the CP violation in the leptonic sector at the second neutrino oscillation maximum using a neutrino beam driven by the uniquely powerful ESS linear accelerator. The reduced impact of systematic errors on sensitivity at the second maximum allows for a very precise measurement of the CP violating parameter. This review describes the fundamental advantages of measurement at the second maximum, the necessary upgrades to the ESS linac in order to produce a neutrino beam, the near and far detector complexes, and the expected physics reach of the proposed ESSnuSB experiment, concluding with the near future developments aimed at the project realization.
  •  
4.
  • Burgman, A., et al. (författare)
  • The European Spallation Source neutrino super-beam conceptual design report
  • 2022
  • Ingår i: The European Physical Journal Special Topics. - : Springer Nature. - 1951-6355 .- 1951-6401. ; 231:21, s. 3779-3955
  • Forskningsöversikt (refereegranskat)abstract
    • A design study, named ESSνSB for European Spallation Source neutrino Super Beam, has been carried out during the years 2018–2022 of how the 5 MW proton linear accelerator of the European Spallation Source under construction in Lund, Sweden, can be used to produce the world’s most intense long-baseline neutrino beam. The high beam intensity will allow for measuring the neutrino oscillations near the second oscillation maximum at which the CP violation signal is close to three times higher than at the first maximum, where other experiments measure. This will enable CP violation discovery in the leptonic sector for a wider range of values of the CP violating phase δCPδCP and, in particular, a higher precision measurement of δCPδCP. The present Conceptual Design Report describes the results of the design study of the required upgrade of the ESS linac, of the accumulator ring used to compress the linac pulses from 2.86 ms to 1.2 μs, and of the target station, where the 5 MW proton beam is used to produce the intense neutrino beam. It also presents the design of the near detector, which is used to monitor the neutrino beam as well as to measure neutrino cross sections, and of the large underground far detector located 360 km from ESS, where the magnitude of the oscillation appearance of νe from νμ is measured. The physics performance of the ESSνSB research facility has been evaluated demonstrating that after 10 years of data-taking, leptonic CP violation can be detected with more than 5 standard deviation significance over 70% of the range of values that the CP violation phase angle δCPδCP can take and that δCPδCP can be measured with a standard error less than 8° irrespective of the measured value of δCPδCP. These results demonstrate the uniquely high physics performance of the proposed ESSνSBESSνSB research facility.
  •  
5.
  • Burgman, A., et al. (författare)
  • Updated physics performance of the ESSnuSB experiment
  • 2021
  • Ingår i: European Physical Journal C. - : Springer Nature. - 1434-6044 .- 1434-6052. ; 81:12
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we present the physics performance of the ESSnuSB experiment in the standard three flavor scenario using the updated neutrino flux calculated specifically for the ESSnuSB configuration and updated migration matrices for the far detector. Taking conservative systematic uncertainties corresponding to a normalization error of 5% for signal and 10% for background, we find that there is 10 sigma (13 sigma) CP violation discovery sensitivity for the baseline option of 540 km (360 km) at delta(CP) = +/- 90 degrees. The corresponding fraction of delta(CP )for which CP violation can be discovered at more than 5 sigma is 70%. Regarding CP precision measurements, the 1 sigma error associated with delta(CP )= 0 degrees is around 5 degrees and with delta(CP )= -90 degrees is around 14 degrees (7 degrees) for the baseline option of 540 km (360 km). For hierarchy sensitivity, one can have 3 sigma sensitivity for 540 km baseline except delta(CP) = +/- 90 degrees and 5 sigma sensitivity for 360 km baseline for all values of delta(CP). The octant of theta(23) can be determined at 30 for the values of: theta(23) > 51 degrees (theta(23) < 42 degrees and theta(23) > 49 degrees) for baseline of 540 km (360 km). Regarding measurement precision of the atmospheric mixing parameters, the allowed values at 3 sigma are: 40 degrees < theta(23) < 52 degrees (42 degrees < theta(23) < 51.5 degrees) and 2.485 x 10(-3) eV(2) < Delta(2)(m31) < 2.545 x 10(-3) eV(2) (2.49x 10(-3 ) eV(2) < Delta(2)(m31) < 2.54 x 10(-3) eV(2)) for the baseline of 540 km (360 km).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy