SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Krsek M.) ;pers:(Braun K. P. J.)"

Sökning: WFRF:(Krsek M.) > Braun K. P. J.

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baumgartner, T., et al. (författare)
  • A survey of the European Reference Network EpiCARE on clinical practice for selected rare epilepsies
  • 2021
  • Ingår i: Epilepsia Open. - : Wiley. - 2470-9239. ; 6:1, s. 160-170
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Clinical care of rare and complex epilepsies is challenging, because evidence-based treatment guidelines are scarce, the experience of many physicians is limited, and interdisciplinary treatment of comorbidities is required. The pathomechanisms of rare epilepsies are, however, increasingly understood, which potentially fosters novel targeted therapies. The objectives of our survey were to obtain an overview of the clinical practice in European tertiary epilepsy centers treating patients with 5 arbitrarily selected rare epilepsies and to get an estimate of potentially available patients for future studies. Methods: Members of the European Reference Network for rare and complex epilepsies (EpiCARE) were invited to participate in a web-based survey on clinical practice of patients with Dravet syndrome, tuberous sclerosis complex (TSC), autoimmune encephalitis, and progressive myoclonic epilepsies including Unverricht Lundborg and Unverricht-like diseases. A consensus-based questionnaire was generated for each disease. Results: Twenty-six of 30 invited epilepsy centers participated. Cohorts were present in most responding centers for TSC (87%), Dravet syndrome (85%), and autoimmune encephalitis (71%). Patients with TSC and Dravet syndrome represented the largest cohorts in these centers. The antiseizure drug treatments were rather consistent across the centers especially with regard to Dravet syndrome, infantile spasms in TSC, and Unverricht Lundborg / Unverricht-like disease. Available, widely used targeted therapies included everolimus in TSC and immunosuppressive therapies in autoimmune encephalitis. Screening for comorbidities was routinely done, but specific treatment protocols were lacking in most centers. Significance: The survey summarizes the current clinical practice for selected rare epilepsies in tertiary European epilepsy centers and demonstrates consistency as well as heterogeneity in the treatment, underscoring the need for controlled trials and recommendations. The survey also provides estimates for potential participants of clinical trials recruited via EpiCARE, emphasizing the great potential of Reference Networks for future studies to evaluate new targeted therapies and to identify novel biomarkers. © 2020 The Authors. Epilepsia Open published by Wiley Periodicals LLC on behalf of International League Against Epilepsy
  •  
2.
  • Mouthaan, B. E., et al. (författare)
  • Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe
  • 2016
  • Ingår i: Epilepsia. - : Wiley. - 0013-9580. ; 57:5, s. 770-776
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. Methods: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. Results: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. Significance: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for highquality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy