SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lancellotti Patrizio) ;pers:(Bax Jeroen J)"

Sökning: WFRF:(Lancellotti Patrizio) > Bax Jeroen J

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Nagueh, Sherif F., et al. (författare)
  • Interobserver Variability in Applying American Society of Echocardiography/European Association of Cardiovascular Imaging 2016 Guidelines for Estimation of Left Ventricular Filling Pressure
  • 2019
  • Ingår i: Circulation Cardiovascular Imaging. - 1941-9651 .- 1942-0080. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Assessment of left ventricular (LV) filling pressure is among the important components of a comprehensive echocardiographic report. Previous studies noted wide limits of agreement using 2009 American Society of Echocardiography/European Association of Echocardiography guidelines, but reproducibility of 2016 guidelines update in estimating LV filling pressure is unknown.METHODS:Echocardiographic and hemodynamic data were obtained from 50 patients undergoing cardiac catheterization for clinical indications. Clinical and echocardiographic findings but not invasive hemodynamics were provided to 4 groups of observers, including experienced echocardiographers and cardiology fellows. Invasively acquired LV filling pressure was the gold standard.RESULTS:In group I of 8 experienced echocardiographers from the guidelines writing committee, sensitivity for elevated LV filling pressure was 92% for all observers, and specificity was 93 +/- 6%. Fleiss kappa-value for the agreement in group I was 0.80. In group II of 4 fellows in training, sensitivity was 91 +/- 2%, and specificity was 95 +/- 2%. Fleiss kappa-value for the agreement in group II was 0.94. In group III of 9 experienced echocardiographers who had not participated in drafting the guidelines, sensitivity was 88 +/- 5%, and specificity was 91 +/- 7%. Fleiss kappa-value for the agreement in group III was 0.76. In group IV of 7 other fellows, sensitivity was 91 +/- 3%, and specificity was 92 +/- 5%. Fleiss kappa-value for the agreement in group IV was 0.89.CONCLUSIONS:There is a good level of agreement and accuracy in the estimation of LV filling pressure using the American Society of Echocardiography/European Association of Cardiovascular Imaging 2016 recommendations update, irrespective of the experience level of the observer.
  •  
4.
  • Rydén, Lars, et al. (författare)
  • ESC Guidelines on diabetes, pre-diabetes, and cardiovascular diseases developed in collaboration with the EASD
  • 2013
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 34:39, s. 3035-3087
  • Tidskriftsartikel (refereegranskat)abstract
    • This is the second iteration of the European Society of Cardiology (ESC) and European Association for the Study of Diabetes (EASD) joining forces to write guidelines on the management of diabetes mellitus (DM), pre-diabetes, and cardiovascular disease (CVD), designed to assist clinicians and other healthcare workers to make evidence-based management decisions. The growing awareness of the strong biological relationship between DM and CVD rightly prompted these two large organizations to collaborate to generate guidelines relevant to their joint interests, the first of which were published in 2007. Some assert that too many guidelines are being produced but, in this burgeoning field, five years in the development of both basic and clinical science is a long time and major trials have reported in this period, making it necessary to update the previous Guidelines.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy